674 research outputs found

    Extraction and sensitive detection of toxins A and B from the human pathogen Clostridium difficile in 40 seconds using microwave-accelerated metal-enhanced fluorescence.

    Get PDF
    Clostridium difficile is the primary cause of antibiotic associated diarrhea in humans and is a significant cause of morbidity and mortality. Thus the rapid and accurate identification of this pathogen in clinical samples, such as feces, is a key step in reducing the devastating impact of this disease. The bacterium produces two toxins, A and B, which are thought to be responsible for the majority of the pathology associated with the disease, although the relative contribution of each is currently a subject of debate. For this reason we have developed a rapid detection assay based on microwave-accelerated metal-enhanced fluorescence which is capable of detecting the presence of 10 bacteria in unprocessed human feces within 40 seconds. These promising results suggest that this prototype biosensor has the potential to be developed into a rapid, point of care, real time diagnostic assay for C. difficile

    “It’s hard to tell”. The challenges of scoring patients on standardised outcome measures by multidisciplinary teams: a case study of Neurorehabilitation

    Get PDF
    Background Interest is increasing in the application of standardised outcome measures in clinical practice. Measures designed for use in research may not be sufficiently precise to be used in monitoring individual patients. However, little is known about how clinicians and in particular, multidisciplinary teams, score patients using these measures. This paper explores the challenges faced by multidisciplinary teams in allocating scores on standardised outcome measures in clinical practice. Methods Qualitative case study of an inpatient neurorehabilitation team who routinely collected standardised outcome measures on their patients. Data were collected using non participant observation, fieldnotes and tape recordings of 16 multidisciplinary team meetings during which the measures were recited and scored. Eleven clinicians from a range of different professions were also interviewed. Data were analysed used grounded theory techniques. Results We identified a number of instances where scoring the patient was 'problematic'. In 'problematic' scoring, the scores were uncertain and subject to revision and adjustment. They sometimes required negotiation to agree on a shared understanding of concepts to be measured and the guidelines for scoring. Several factors gave rise to this problematic scoring. Team members' knowledge about patients' problems changed over time so that initial scores had to be revised or dismissed, creating an impression of deterioration when none had occurred. Patients had complex problems which could not easily be distinguished from each other and patients themselves varied in their ability to perform tasks over time and across different settings. Team members from different professions worked with patients in different ways and had different perspectives on patients' problems. This was particularly an issue in the scoring of concepts such as anxiety, depression, orientation, social integration and cognitive problems. Conclusion From a psychometric perspective these problems would raise questions about the validity, reliability and responsiveness of the scores. However, from a clinical perspective, such characteristics are an inherent part of clinical judgement and reasoning. It is important to highlight the challenges faced by multidisciplinary teams in scoring patients on standardised outcome measures but it would be unwarranted to conclude that such challenges imply that these measures should not be used in clinical practice for decision making about individual patients. However, our findings do raise some concerns about the use of such measures for performance management

    Avaliação das técnicas de massagem e ordenha no tratamento do ingurgitamento mamário por termografia

    Get PDF
    OBJETIVO: evaluar los métodos de masaje y bombeo en el tratamiento de la congestión mamaria posparto a través de la termografía. MÉTODO: el estudio se realizó en el Banco de Leche Humana de un hospital en Curitiba, Brasil. Se seleccionaron al azar 16 mujeres en periodo de lactancia con congestión con clasificación lobar, ampular y glandular, moderada e intensa. Se compararon los patrones diferenciales de temperatura, antes y después del tratamiento por medio de masaje y bombeo. RESULTADOS: se encontró un degradado negativo de 0,3°C de temperatura entre el pre y post-tratamiento en el grupo experimental. Las mamas con intensa congestión eran 0,7°C más caliente en comparación a aquellos con congestión moderada. CONCLUSIÓN: el masaje y el bombeo electromecánico fueron superiores a los métodos manuales cuando se evaluaron por termografía. REBEC: U1111-1136-9027.OBJETIVO: avaliar técnicas de massagem e ordenha no tratamento do ingurgitamento mamário puerperal, por meio da termografia. MÉTODO: a pesquisa foi realizada no Banco de Leite Humano de um hospital de Curitiba, Brasil. Selecionaram-se, aleatoriamente, 16 lactantes com ingurgitamento com classificação lobar, ampolar e glandular moderado e intenso. Compararam-se os padrões diferenciais de temperatura, antes e após o tratamento realizado, por meio de massagem e ordenha. RESULTADOS: constatou-se um gradiente negativo de 0,3ºC de temperatura entre o pré e o pós-tratamento no grupo experimental. Mamas com ingurgitamento intenso foram 0,7ºC mais quentes quando comparadas com ingurgitamento moderado. CONCLUSÃO: a massagem e ordenha eletromecânicas são superiores às manuais, quando avaliadas por termografia. REBEC: U1111-1136-9027.OBJECTIVE: to evaluate techniques of massage and pumping in the treatment of postpartum breast engorgement through thermography. METHOD: the study was conducted in the Human Milk Bank of a hospital in Curitiba, Brazil. We randomly selected 16 lactating women with engorgement with the classification lobar, ampullary and glandular, moderate and intense. We compared the differential patterns of temperature, before and after the treatment by means of massage and pumping. RESULTS: we found a negative gradient of 0.3°C of temperature between the pre- and post-treatment in the experimental group. Breasts with intense engorgement were 0.7°C warmer when compared with moderate engorgement. CONCLUSION: massage and electromechanical pumping were superior to manual methods when evaluated by thermography. REBEC: U1111-1136-9027

    Classic Kaposi's sarcoma in Italy, 1985–1998

    Get PDF
    To evaluate incidence rates (IRs) of classic Kaposi's sarcoma (CKS) in Italy after the spread of AIDS, we distinguished CKS from AIDS-related KS (AKS) using an ‘ad hoc' record linkage procedure between 15 Cancer Registries (CRs) (21% of the Italian population) and the national AIDS Registry. Between 1985 and 1998, 874 cases of CKS and 634 cases of AKS were diagnosed in the study areas. CKS accounted for 16 and 27% of KS cases below 55 years of age in men and women, respectively, but for 91 and 100% of those above age 55. The IRs for CKS were 1.0/ in men and 0.4/100 000 in women, but they varied between 0.3 in Umbria and 4.7 in Sassari in men, and between 0.1 in Parma and 1.7 in Sassari in women. IRs of CKS in both genders were stable between 1985–1987 and 1993–1998. In Northern and Central CRs the IR (adjusted for age and gender) for CKS was 0.5 in individuals born in the same area, but 1.6 in individuals born in Southern Italy or in the Islands (rate ratio=3.2) suggesting that KS-associated herpesvirus, the cause of KS, is acquired early in life

    Ultra-Fast and Sensitive Detection of Non-Typhoidal Salmonella Using Microwave-Accelerated Metal-Enhanced Fluorescence (“MAMEF”)

    Get PDF
    Certain serovars of Salmonella enterica subsp. enterica cause invasive disease (e.g., enteric fever, bacteremia, septicemia, meningitis, etc.) in humans and constitute a global public health problem. A rapid, sensitive diagnostic test is needed to allow prompt initiation of therapy in individual patients and for measuring disease burden at the population level. An innovative and promising new rapid diagnostic technique is microwave-accelerated metal-enhanced fluorescence (MAMEF). We have adapted this assay platform to detect the chromosomal oriC locus common to all Salmonella enterica subsp. enterica serovars. We have shown efficient lysis of biologically relevant concentrations of Salmonella spp. suspended in bacteriological media using microwave-induced lysis. Following lysis and DNA release, as little as 1 CFU of Salmonella in 1 ml of medium can be detected in <30 seconds. Furthermore the assay is sensitive and specific: it can detect oriC from Salmonella serovars Typhi, Paratyphi A, Paratyphi B, Paratyphi C, Typhimurium, Enteritidis and Choleraesuis but does not detect Escherichia coli, Pseudomonas aeruginosa, Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae or Acinetobacter baumanii. We have also performed preliminary experiments using a synthetic Salmonella oriC oligonucleotide suspended in whole human blood and observed rapid detection when the sample was diluted 1∶1 with PBS. These pre-clinical data encourage progress to the next step to detect Salmonella in blood (and other ordinarily sterile, clinically relevant body fluids)

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Prospective study comparing skin impedance with EEG parameters during the induction of anaesthesia with fentanyl and etomidate

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>Sympathetic stimulation leads to a change in electrical skin impedance. So far it is unclear whether this effect can be used to measure the effects of anaesthetics during general anaesthesia. The aim of this prospective study is to determine the electrical skin impedance during induction of anaesthesia for coronary artery bypass surgery with fentanyl and etomidate.</p> <p>Methods</p> <p>The electrical skin impedance was measured with the help of an electro-sympathicograph (ESG). In 47 patients scheduled for elective cardiac surgery, anaesthesia was induced with intravenous fentanyl 10 μg/kg and etomidate 0.3 mg/kg. During induction, the ESG (Electrosympathicograph), BIS (Bispectral IndeX), BP (arterial blood pressure) and HR (heart rate) values of each patient were recorded every 20 seconds. The observation period from administration of fentanyl to intubation for surgery lasted 4 min.</p> <p>Results</p> <p>The ESG recorded significant changes in the electrical skin impedance after administration of fentanyl and etomidate(p < 0.05). During induction of anaesthesia, significant changes of BIS, HR and blood pressure were observed as well (p < 0.05).</p> <p>Conclusions</p> <p>The electrical skin impedance measurement may be used to monitor the effects of anesthetics during general anaesthesia.</p
    corecore