88 research outputs found

    “It’s embarrassing. I get angry. I get frustrated.”: Understanding severe hypoglycemia and glucagon usage from the perspectives of people with type 1 diabetes

    Get PDF
    Introduction This study characterized the emotional impact of severe hypoglycemia, views of glucagon, and barriers to glucagon use from the perspective of adults with type 1 diabetes (T1D). Methods Participants included individuals recruited from the T1D Exchange online community. The current study conducted 7 focus groups consisting of adults with T1D (N = 38, average age 49.4, SD = 16.11 years). Average duration of diabetes was 34.4 years (SD = 17.3) and average self-reported A1c was 6.8 % (SD = 0.7). Focus group interviews were recorded, transcribed, and thematically analyzed. Results A range of emotions was expressed about severe hypoglycemia including fear, anxiety, stress, frustration, shame, and embarrassment. Participants frequently identified prescription cost and insurance deductibles as barriers to glucagon use. Participants were also concerned about ease of administration—how difficult it is to prepare the glucagon in an emergency. Many participants expressed a preference for auto-injectables over nasal administration. Timing of glucagon action and time to recovery were high priorities. Some participants, while they had not self-administered glucagon, were interested in a mini-dose glucagon they could self-administer. They also identified desirable characteristics of glucagon treatment including reduced cost, long shelf-life, and quick activation. Conclusions These results highlight the attitudes about severe hypoglycemia and emergency treatment with glucagon. Healthcare professionals should assess glucagon training needs and knowledge when they meet with their patients with diabetes

    Effect of Age of Infusion Site and Type of Rapid-Acting Analog on Pharmacodynamic Parameters of Insulin Boluses in Youth With Type 1 Diabetes Receiving Insulin Pump Therapy

    Get PDF
    OBJECTIVE—The purpose of this study was to examine the effect of type of insulin analog and age of insertion site on the pharmacodynamic characteristics of a standard insulin bolus in youth with type 1 diabetes receiving insulin pump therapy

    Comparison of hypoxia transcriptome in vitro with in vivo gene expression in human bladder cancer

    Get PDF
    Hypoxia-inducible genes have been linked to the aggressive phenotype of cancer. However, nearly all work on hypoxia-regulated genes has been conducted in vitro on cell lines. We investigated the hypoxia transcriptome in primary human bladder cancer using cDNA microarrays to compare genes induced by hypoxia in vitro in bladder cancer cell line EJ28 with genes upregulated in 39 bladder tumour specimens (27 superficial and 12 invasive). We correlated array mRNA fold changes with carbonic anhydrase 9 (CA IX) staining of tumours as a surrogate marker of hypoxia. Of 6000 genes, 32 were hypoxia inducible in vitro more than two-fold, five of which were novel, including lactate transporter SLC16A3 and RNAse 4. Eight of 32 hypoxia-inducible genes in vitro were also upregulated on the vivo array. Vascular endothelial growth factor mRNA was upregulated two-fold by hypoxia and 2–18-fold in 31 out of 39 tumours. Glucose transporter 1 was also upregulated on both arrays mRNA, and fold changes on the in vivo array significantly correlated with CA IX staining of tumours (P=0.008). However, insulin-like growth factor binding protein 3 mRNA was the most strongly differentially expressed gene in both arrays and this confirmed its upregulation in urine of bladder cancer patients (n=157, P<0.01). This study defines genes suitable for an in vivo hypoxia ‘profile', shows the heterogeneity of the hypoxia response and describes new hypoxia-regulated genes

    Clinical targets for continuous glucose monitoring data interpretation : recommendations from the international consensus on time in range

    Get PDF
    Improvements in sensor accuracy, greater convenience and ease of use, and expanding reimbursement have led to growing adoption of continuous glucose monitoring (CGM). However, successful utilization of CGM technology in routine clinical practice remains relatively low. This may be due in part to the lack of clear and agreed-upon glycemic targets that both diabetes teams and people with diabetes can work toward. Although unified recommendations for use of key CGM metrics have been established in three separate peer-reviewed articles, formal adoption by diabetes professional organizations and guidance in the practical application of these metrics in clinical practice have been lacking. In February 2019, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address this issue. This article summarizes the ATTD consensus recommendations for relevant aspects of CGM data utilization and reporting among the various diabetes populations

    Closed-loop insulin delivery for treatment of type 1 diabetes

    Get PDF
    Type 1 diabetes is one of the most common endocrine problems in childhood and adolescence, and remains a serious chronic disorder with increased morbidity and mortality, and reduced quality of life. Technological innovations positively affect the management of type 1 diabetes. Closed-loop insulin delivery (artificial pancreas) is a recent medical innovation, aiming to reduce the risk of hypoglycemia while achieving tight control of glucose. Characterized by real-time glucose-responsive insulin administration, closed-loop systems combine glucose-sensing and insulin-delivery components. In the most viable and researched configuration, a disposable sensor measures interstitial glucose levels, which are fed into a control algorithm controlling delivery of a rapid-acting insulin analog into the subcutaneous tissue by an insulin pump. Research progress builds on an increasing use of insulin pumps and availability of glucose monitors. We review the current status of insulin delivery, focusing on clinical evaluations of closed-loop systems. Future goals are outlined, and benefits and limitations of closed-loop therapy contrasted. The clinical utility of these systems is constrained by inaccuracies in glucose sensing, inter- and intra-patient variability, and delays due to absorption of insulin from the subcutaneous tissue, all of which are being gradually addressed.Supported by the Juvenile Diabetes Research Foundation (#22-2006-1113, #22-2007-1801, #22-2009-801), Diabetes UK (BDA07/0003549, BDA07/0003551), European Commission Framework Programme 7 (247138), NIDDK (DK085621), and NIHR Cambridge Biomedical Research Centre
    corecore