2,655 research outputs found

    Effects of Forage Cover on Run-Off and Soil Losses in Different Productive Systems in Central Italy

    Get PDF
    A trial has been carried out for four years, in a hilly area of Central Italy, on five covers concerning three different productive systems: traditional system based on the rotation of Medicago sativa and barley; low input system based on permanent association of grasses and legumes; annual self-reseeding legumes used as cover crop in vineyard. The pasture had the higher run-off but also the lower soil erosion thanks to the high number of plants per square metre which were able to hold the soil particles. The inherbment of the vineyard prevented greater soil erosion commonly known in cultivated grooves

    Use of Annual Self-Reseeding Legumes in an Oak Forest in Central Italy

    Get PDF
    A trial has been carried out for three years in an oak coppice geometrically thinned out of Mediterranean Central Italy, about the functioning of a pastoral system made by four different resources: native pasture, subterranean clover (Trifolium brachycalycinum Katzn. et Morley) in pure stand, strips thinned out and firebreaks improved with oversown subclover, all grazed by sheep. Subclover increased the forage yield and improved the palatabilty of the pasture and the regularity of grazing; the higher biomass intake by animals reduced the quantity of dried biomass in summer and contributed to keep low either fire hazards or flame diffusion speed. Data underlined the importance of deferred grazing and of the combination of different native or improved resources on the seasonal distribution of production and animal intake

    The influence of soft acidic drinks in exposing dentinal tubules after non-surgical periodontal treatment: : a SEM investigation on the protective effects of oxalate-containing phytocomplex

    Get PDF
    Objective: The aim of this study was to investigate the different smear layer morphologies produced by instrumentation with a hand curette and a periodontal sonic scaler for potential removal by soft acidic solution. The effect of a new oxalate-containing phytocomplex spray in preventing tubules exposure after citric acid solution application was also evaluated. Methods: Thirty recently extracted human teeth were used to obtain root dentinal fragments and divided in two groups: Curette treatment (CRT) root planed applying 30 working strokes to each surface using a Gracey?s curette 5-6 and Ultrasonic scaler (USC) treated using a periodontal scaler mounted on an ultrasonic hand-piece for 30 seconds. Each principal group was further divided in three sub-groups (Control, Acid challenge and Acid/Phyto-oxalate). The control group samples were immersed in distilled water buffered to pH 7.4 using NH4 OH solution. The samples of the acid challenge group were immersed in a solution of citric acid 0,02M; [pH 2.5] for 3 minutes. The samples of the Acid/Phyto-oxalate group were sprayed for 15 sec with a 1.5% phytocomplex spray prior to immersion. Samples were examined using SEM. Results: Ultrasonic instrumentation created a very thin smear layer whereas curettes produced a multilayered smear layer. The acidic solution was able to remove the smear layer from root surfaces treated with ultrasonic instrumentation exposing the dentinal tubules. The smear layer on the root surfaces treated with hand instruments was not completely removed. The phytocomplex solution was able to prevent dentinal tubule exposure. Conclusions: Acidic soft drinks are able to remove the smear layer created on root surfaces during different non-surgical periodontally treatments. The smear plugs created by hand instrumentation appeared to be more resistant to acid attack. The tested phytocomplex solution protected the dentine from demineralization and it might prevent post-treatment dentinal hypersensitivity induced by acidic soft drinks

    Slow VT treatment in a contemporary population of primary prevention ICD recipients

    Get PDF
    Abstract Funding Acknowledgements Type of funding sources: None. Background Implantable cardioverter defibrillator (ICD) is an effective therapy for sudden cardiac death (SCD). 2015 HRS/EHRA/APHRS/SOLAECE expert consensus document suggests long VT detection, above 185 bpm, as optimal ICD programming to reduce unnecessary therapies in primary prevention (PP). Purpose The aim of our study is to evaluate incidence, safety and efficacy of ICD treatment for VT arrhythmias below 185 bpm, in a contemporary population of PP ICD recipients with long detection intervals (LDI), morphological discrimination algorithm and antitachycardia pacing therapies (ATP) before shock. Methods We conducted a single centre retrospective study enrolling 236 patients implanted with a primary-prevention indication from January 2013 to June 2019. Patients were implanted with single or dual chamber single-lead transvenous ICD. All patients had standard device setting with long (at least 20 s in VT and 7 s in VF) VT/VF detection above 150 bpm and therapies starting from 171 with up to 5 ATP and multiple shocks. PainFREE-like bursts and Schaumann-like ramps ATP were always set in VT zone. Of each patient we collected a detailed report of up to five appropriate events and three inappropriate events. Arrhythmia diagnosis was confirmed from 3 independent expert physicians. Date of the event, cycle length, type of morphology (polymorphic or monomorphic), therapies with their effect were collected. Results During a mean follow-up of 42 months, 47 (20 %) and 18 (8%) patients had at least one appropriate and inappropriate activation, respectively. The detailed-events analysis shows that 16 (7%) patients had 38 (30%) appropriate events with rate <188 bpm. At these rate ATP were 97% effective. 14 (38%) of inappropriate activations were caused by arrythmias with ventricular rate below 188 bpm and half of these received a shock; 30% of inappropriate shocks were due to arrhythmia with rate <188 bpm. 73% of treated events, with rate <188 bpm, were appropriate. Only 5.6% (n = 10) of ATP attempts cause arrhythmia acceleration. Conclusions One third of detected arrhythmias had a rate below 188 bpm and 73% were true VT. In this slow VT zone, ATP had a high success rate with low percentage of acceleration

    Bridging the future of cardiac stimulation: physiologic or leadless pacing?

    Get PDF
    Cardiac simulation has moved from early life-saving pacemakers meant only to prevent asystole to current devices capable of physiologic stimulation for the treatment of heart rhythm and heart failure, that are also intended for remote patient and disease-progression monitoring. The actual vision of contemporary pacing aims to correct the electrophysiologic roots of mechanical inefficiency regardless of underlying structural heart diseases. The awareness of the residual cardiac dyssynchrony related to customary cardiac pacing has changed the concept of what truly represents “physiologic pacing”. On a different perspective, leadless stimulation to abolish CIED surgery and prevent lead-related complications is becoming a priority both for young device recipients and for frail, elderly patients. Careful clinical evaluation attempts to bridge decision-making to patient-tailored therapy

    The importance of WNT pathways for bone metabolism and their regulation by implant topography

    Get PDF
    Endosseous implants are important tools to replace missing teeth or damaged tissue segments. Their clinical success depends on their integration in bone and, thus, on the response of bone cells to material and surface characteristics. Recent evidence has shown that surface topography and chemistry affect WNT signalling, a pivotal pathway for the commitment of mesenchymal progenitors to the osteoblast lineage and for bone homeostasis. WNT signalling comprises several cascades that, acting through different effectors, modulate several aspects of cell behaviour.It has been shown that cells growing on rough titanium surfaces display a different expression profile for WNT factors, and that surface features can alter the response of bone cells to WNT factors. Although the underlying mechanisms to this regulation are still poorly understood, the present review reports intriguing evidence that that cell cytoskeletal signalling is involved in activating WNT signalling in cells growing on rough implant surfaces

    Tolerance and Safety Evaluation in a Large Cohort of Healthy Infants Fed an Innovative Prebiotic Formula: A Randomized Controlled Trial

    Get PDF
    Background: the addition of oligosaccharides to infant formula has been shown to mimic some of the beneficial effects of human milk. The aim of the study was to assess the tolerance and safety of a formula containing an innovative mixture of oligosaccharides in early infancy. Methodology/Principal Findings: this study was performed as a multi-center, randomized, double-blind, placebo-controlled trial including healthy term infants. Infants were recruited before the age of 8 weeks, either having started with formula feeding or being fully breast-fed (breastfeeding group). Formula-fed infants were randomized to feeding with a regular formula containing a mixture of neutral oligosaccharides and pectin-derived acidic oligosaccharides (prebiotic formula group) or regular formula without oligosaccharides (control formula group). Growth, tolerance and adverse events were assessed at 8, 16, 24 and 52 weeks of age. The prebiotic and control groups showed similar mean weight, length and head circumference, skin fold thicknesses, arm circumference gains and stool frequency at each study point. As far as the anthropometric parameters are concerned, the prebiotic group and the control group did not attain the values shown by the breastfeeding group at any study point. The skin fold thicknesses assessed in the breastfeeding group at 8 weeks were strikingly larger than those in formula fed infants, whereas at 52 weeks were strikingly smaller. The stool consistency in the prebiotic group was softer than in the control group at 8, 16 and 24 weeks (p <0.001) and closer to that of the breastfeeding group. There was no difference in the incidence of adverse events between the two formula groups. Conclusions: our findings demonstrate the tolerability and the long term safety of a formula containing an innovative mixture of oligosaccharides in a large cohort of healthy infants

    Direct Measurements of A_b and A_c using Vertex/Kaon Charge Tags at SLD

    Get PDF
    Exploiting the manipulation of the SLC electron-beam polarization, we present precise direct measurements of the parity violation parameters A_c and A_b in the Z boson - c quark and Z boson - b quark coupling. Quark/antiquark discrimination is accomplished via a unique algorithm that takes advantage of the precise SLD CCD vertex detector, employing the net charge of displaced vertices as well as the charge of kaons that emanate from those vertices. From the 1996-98 sample of 400,000 Z decays, produced with an average beam polarization of 73.4%, we find A_c = 0.673 +/- 0.029 (stat.) +/- 0.023 (syst.) and A_b = 0.919 +/- 0.018 (stat.) +/- 0.017 (syst.).Comment: 11 pages, 2 figures, 2 tables, to be submitted to Physical Review Letters; version 2 reflects changes suggested by the refere
    corecore