979 research outputs found

    Effect of dose and frequency of prostaglandin F2α treatments during a 7-day Ovsynch protocol with an intravaginal progesterone releasing device on luteal regression and pregnancy outcomes in lactating Holstein cows

    Get PDF
    Our objective was to evaluate the effect of 3 different Ovsynch protocols on progesterone (P4) and pregnancies per artificial insemination (P/AI), where all cows received a P4 releasing intravaginal device (PRID) from d 0 until d 8. We hypothesized that (1) both modified PGF2α treatments lead to decreased P4 at the second GnRH treatment (G2), resulting in greater P/AI, (2) the treatment effect is influenced by the presence of a corpus luteum (CL) at the beginning of the protocol, and (3) potential vaginal discharge caused by the PRID does not have a negative influence on fertility. Lactating Holstein cows (n = 1,056) were randomly assigned to 1 of 3 treatment groups on a weekly basis (n = 356; control: d 0, 100 ”g of GnRH + PRID; d 7, 25 mg of dinoprost; d 8, PRID removal; d 9, 100 ”g of GnRH). Cows in the second group (n = 353) received an Ovsynch protocol with a double dose of PGF2α (DoubleDose: d 0, 100 ”g of GnRH + PRID; d 7, 50 mg of dinoprost; d 8, PRID removal; d 9, 100 ”g of GnRH). Cows in the third group (n = 347) received an Ovsynch protocol with a second PGF2α treatment 24 h after the first one (2PGF: d 0, 100 ”g of GnRH + PRID; d 7, 25 of mg dinoprost; d 8, 25 mg of dinoprost and PRID removal; d 9, 100 ”g of GnRH). All cows had their ovaries scanned to determine the presence of a CL at the beginning of the Ovsynch protocol. Vaginal discharge score (VS) was evaluated at PRID removal. All cows received timed artificial insemination approximately 16 h after G2. Pregnancy diagnosis was performed via transrectal ultrasonography (d 38 ± 3 after timed artificial insemination) and rechecked on d 80 ± 7 after timed artificial insemination. Blood samples were collected on d 0, 7, and 9 of the protocol to determine P4 concentrations. Treatment affected P4 at G2. Progesterone was lower for 2PGF and DoubleDose cows compared with cows in the control group (control 0.35 ± 0.02 ng/mL; DoubleDose 0.29 ± 0.02 ng/mL; 2PGF 0.30 ± 0.02 ng/mL). Overall, P/AI did not differ among treatments. We found, however, an interaction between treatment and CL at the first GnRH treatment. Cows lacking a CL at the first GnRH treatment in the 2PGF group had greater P/AI (47.9%) compared with the same type of cows in the DoubleDose group (32.7%). We observed an effect of VS on P4 concentration at d 7. We found an increase in P4 with greater VS. Vaginal discharge score at PRID removal tended to have a positive effect on P/AI at d 38 (VS0: 36.5%; VS1: 41.3%; VS2: 49.7%). In conclusion, the addition of a second PGF treatment on d 7 and 8 of a 7-d Ovsynch protocol increased luteal regression and decreased mean P4 at G2. Cows treated with PGF2α 2 times 24 h apart showed greater P/AI, compared with cows treated with an increased dose of PGF2α

    Effect of a progesterone-releasing intravaginal device (PRID) for 8 days during a modified Ovsynch protocol on pregnancy outcomes in lactating Holstein cows

    Get PDF
    Our objective was to evaluate the effect of a progesterone-releasing intravaginal device (PRID) in a 7-d Ovsynch protocol on pregnancy per artificial insemination (P/AI) and pregnancy loss, compared with a standard 7-d Ovsynch protocol without progesterone supplementation. We hypothesized that progesterone supplementation during an Ovsynch protocol would increase P/AI and decrease pregnancy loss. Data were collected on lactating Holstein cows (n = 716) that either received a 7-d Ovsynch protocol (control: d 0, 100 ”g of GnRH; d 7, 500 ”g of cloprostenol; d 9, ”g of GnRH; n = 360) or a modified Ovsynch protocol with addition of a PRID (PRIDsynch; d 0, 100 ”g of GnRH + PRID; d 7, 25 mg of dinoprost; d 8, PRID removal; d 9, 100 ”g of GnRH; n = 356). All cows received timed artificial insemination (TAI) approximately 16 h after the second GnRH treatment. Pregnancy diagnosis was performed via ultrasonography on d 38 ± 3 after TAI and rechecked on d 80 ± 7 after TAI. Reproductive performance differed between treatments, with PRIDsynch cows having greater (38.9%) P/AI compared with control cows (31.7%) at d 38 ± 3 and also at d 80 ± 7 (34.6% vs. 28.9%, for PRIDsynch and control cows, respectively). Pregnancy loss did not differ among treatments

    Evaluation of laboratory and on-farm tests to estimate colostrum quality for dairy cows

    Get PDF
    The objectives of this study were to evaluate different analytical methods to determine colostrum quality in dairy cattle, including one laboratory-based method (ELISA) and 4 on-farm tests. We hypothesized that the colostral IgG concentration using different analytical methods, such as ELISA (mg/mL), digital Brix refractometer (% Brix), colostrometer (specific gravity and mg/mL), an outflow funnel (seconds), and a lateral flow assay (mg/mL), were highly correlated with the reference method, radial immunodiffusion (RID; mg/mL) and would generate comparable results. Colostrum samples were collected from 209 Holstein Friesian cows on 2 commercial dairy farms in Germany. Colostrum weight and colostrum temperature were measured. Test characteristics, such as optimum thresholds, sensitivity, specificity, and area under the curve (AUC) were determined using a receiver operating characteristic curve analyses for each test. Out of 209 colostrum samples assessed by RID, 186 (89%) samples had high quality (≄50 mg IgG/mL), while 23 colostrum samples (11%) showed poor quality with IgG concentrations less than 50 mg/mL. The mean IgG concentration (±SD) was 101.3 ± 45.9 mg/mL and the range was 6.0 to 244.3 mg/mL. The Pearson correlation coefficient (r) between RID and ELISA was r = 0.78. In comparison to RID, Pearson correlation coefficients for the on-farm tests were: r = 0.79 (digital Brix refractometry), r = 0.58 (colostrometer: specific gravity), r = 0.61 (colostrometer: temperature corrected), r = 0.26 (outflow funnel) and r = 0.43 (lateral flow assay), respectively. The optimal threshold to identify high-quality colostrum using ELISA was 50.8 mg/mL with sensitivity 91.3%, specificity 92.3%, and AUC of 0.94. For the on-farm tests sensitivity ranged from 95.7% (Brix refractometry) to 60.9% (lateral flow assay). Specificity ranged from 88.6% (lateral flow assay) to 75.9% (colostrometer: temperature corrected). The AUC ranged from 0.93 (Brix refractometry) to 0.73 (outflow funnel). Based on the AUC, ELISA (0.94) and Brix refractometry (0.93) can be considered highly accurate. In conclusion, the ELISA is accurate to assess colostrum quality. Regarding the on-farm tests only the digital Brix refractometer and the colostrometer were adequate to determine colostrum quality

    Part 1. Inflammatory and metabolic markers, uterine health, and indicators of pain

    Get PDF
    The objectives of this study were to assess the effects of a single transdermal administration of flunixin meglumine (FM) in early postpartum Holstein Friesian dairy cows on serum concentrations of inflammatory and metabolic markers, uterine health, and indicators of pain. The hypothesis was that the anti-inflammatory, antipyretic, and analgetic effects of the pharmaceutic agent would reduce systemic inflammation, resulting in improved metabolic and inflammatory profile, diminished incidence of metritis, and reduced expression of pain. A total of 500 cows (153 primiparous, 347 multiparous) from 3 different commercial dairy farms in the northeast of Germany were included in a randomized controlled clinical trial. Farms were preselected based on high haptoglobin concentrations in their fresh lactating cows. Cows were excluded if they had experienced dystocia, stillbirth, or twin birth, or if they showed any signs of milk fever, retained fetal membranes, or fever (>40°C). The cows were treated once with either FM (3.33 mg/kg) or a placebo as control (CON) through transdermal administration between 24 to 36 h postpartum (d 2). General health examinations were performed (daily from d 2–8 and additionally on d 15 postpartum), vaginal discharge was assessed using the Metricheck device (d 8 and 15 postpartum) and serum samples were analyzed for inflammatory and metabolic markers (d 2, 4, and 6 postpartum). Effects of treatment, parity, sampling day, and their interactions were evaluated using mixed effects models. Primiparous cows treated with FM showed lower serum haptoglobin concentrations (0.90 ± 0.08 vs. 1.17 ± 0.07 g/L; ± standard error of the mean) and higher serum albumin concentrations (35.5 ± 0.31 vs. 34.8 ± 0.31 g/L) on d 6 postpartum. They also had a lower risk for purulent vaginal discharge with or without a fever compared with CON cows on d 15 postpartum (odds ratio for CON vs. FM: 1.63, 95% CI: 1.26–2.00), and body temperature was lower throughout the first 15 d in milk (39.1 ± 0.11 vs. 39.2 ± 0.11°C). Multiparous cows treated with FM had lower serum ÎČ-hydroxybutyrate concentrations on d 4 postpartum (0.71 ± 0.05 vs. 0.78 ± 0.05 mmol/L) and d 6 postpartum (0.74 ± 0.05 vs. 0.80 ± 0.05 mmol/L). Regardless of parity, FM-treated cows were significantly less likely to abduct their tail from their body (14.3 vs. 23.6%) and show an arched back (27.9 vs. 39.7%) on the day after treatment compared with CON cows. It can be concluded that FM treatment slightly reduced inflammation and diminished the risk for metritis in primiparous cows, improved metabolic profile in multiparous cows, and reduced expressions of pain in all cows

    Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices

    Get PDF
    Background Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. Results The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73 % for the FSP, 81 % for the GLX and 41 % for the WGC. Bland- Altman plots showed biases of −18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80 %. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92 %, Sp = 85 %) and 95 mg/dL (Se = 39 %, Sp = 92 %). Conclusions The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations

    Juxtaposition of Spin Freezing and Long Range Order in a Series of Geometrically Frustrated Antiferromagnetic Gadolinium Garnets

    Full text link
    Specific heat measurements in zero magnetic field are presented on a homologous series of geometrically frustrated, antiferromagnetic, Heisenberg garnet systems. Measurements of Gd3Ga5O12, grown with isotopically pure Gd, agree well with previous results on samples with naturally abundant Gd, showing no ordering features. In contrast, samples of Gd3Te2Li3O12 and Gd3Al5O12 are found to exhibit clear ordering transitions at 243 mK and 175 mK respectively. The effects of low level disorder are studied through dilution of Gd3+ with non-magnetic Y3+ in Gd3Te2Li3O12. A thorough structural characterization, using X-ray diffraction, is performed on all of the samples studied. We discuss possible explanations for such diverse behavior in very similar systems.Comment: Accepted for publication in Physical Review

    Evolution of porosity in carbide-derived carbon aerogels

    Get PDF
    Carbide-derived carbon (CDC) aerogel monoliths with very high porosity are synthesized starting from polymeric precursors. Cross-linking by platinum-catalyzed hydrosilylation of polycarbosilanes followed by supercritical drying yields preceramic aerogels. After ceramic conversion and silicon extraction in hot chlorine gas, hierarchically porous carbon materials with specific surface areas as high as 2122 mÂČ g⁻Âč and outstanding total pore volumes close to 9 cmÂł g⁻Âč are obtained. Their pore structure is controllable by the applied synthesis temperature as shown by combined nitrogen (-196 °C) and carbon dioxide (0 °C) measurements coupled with electron microscopic methods. The combination of large micropore volumes and the aerogel-type pore system leads to advanced adsorption properties due to a combination of large storage capacities and effective materials transport in comparison with purely microporous reference materials as shown by thermal response measurements
    • 

    corecore