348 research outputs found

    Variational collision integrator for polymer chains

    Get PDF
    The numerical simulation of many-particle systems (e.g., in molecular dynamics) often involves constraints of various forms. We present a symplectic integrator for mechanical systems with holonomic (bilateral) and unilateral contact constraints, the latter being in the form of a nonpenetration condition. The scheme is based on a discrete variant of Hamilton’s principle in which both the discrete trajectory and the unknown collision time are varied (cf. [Fetecau et al., 2003, SIAM J. Applied Dynamical Systems, 2, pp. 381–416]). As a consequence, the collision event enters the discrete equations of motion as an unknown that has to be computed on-the-fly whenever a collision is imminent. The additional bilateral constraints are e ciently dealt with employing a discrete null space reduction (including a projection and a local reparametrisation step) which considerably reduces the number of unknowns and improves the condition number during each time-step as compared to a standard treatment with Lagrange multipliers. We illustrate the numerical scheme with a simple example from polymer dynamics, a linear chain of beads, and test it against other standard numerical schemes for collision problems

    Differential Geometry applied to Acoustics : Non Linear Propagation in Reissner Beams

    Full text link
    Although acoustics is one of the disciplines of mechanics, its "geometrization" is still limited to a few areas. As shown in the work on nonlinear propagation in Reissner beams, it seems that an interpretation of the theories of acoustics through the concepts of differential geometry can help to address the non-linear phenomena in their intrinsic qualities. This results in a field of research aimed at establishing and solving dynamic models purged of any artificial nonlinearity by taking advantage of symmetry properties underlying the use of Lie groups. The geometric constructions needed for reduction are presented in the context of the "covariant" approach.Comment: Submitted to GSI2013 - Geometric Science of Informatio

    Разработка алгоритма для выполнения операции обратного проецирования

    Get PDF
    High Power Pulsed Magnetron Sputtering (HPPMS) techniques jointly with the deposition of a graded Cr/CrN-nanointerlayer on cutting inserts can increase the film adhesion and consequently the tool life. These improvements depend on the roughness of the employed cemented carbide substrates. The investigations described in the present paper intend to explain the effect of Cr/CrN-interlayer thickness and substrate roughness on the coating adhesion and cutting performance. To attain various roughnesses, the applied cemented carbide inserts were superficially treated. These treatments were grinding at a medium roughness level, or grinding with subsequent polishing for enhancing the surface integrity and finally, in all cases, micro-blasting by fine Al2O3 grains. After Ar-ion etching, graded Cr/CrN adhesive layers with different thicknesses were deposited by HPPMS technology on the variously pretreated substrates. Subsequently, an approximately 3m thick (Ti,Al)N film was depos ited by HPPMS PVD on all used inserts. Rockwell C indentations and inclined impact tests were performed to assess qualitatively and quantitatively the films' adhesion. The cutting performance of the coated tools was investigated in milling of 42CrMo4 QT. FEM supported calculations of the developed stresses during the material removal process contributed in explaining the obtained tool wear results. In these calculations, the adhesion, dependent on the substrate roughness characteristics and on the adhesive interlayer thickness, was taken into account. The results revealed that the effectiveness of HPPMS adhesive graded Cr/CrN-nanointerlayer strongly depends on the substrate surface integrity and on the interlayer thickness. Thus, the film adhesion and consequently the cutting performance can be significantly improved if the interlayer thickness is adapted to the substrate roughness

    MRI characterization of 124 CT-indeterminate focal hepatic lesions: evaluation of clinical utility

    Get PDF
    Objective. To evaluate the diagnostic yield of MRI performed for characterization of focal hepatic lesions that are interpreted as indeterminate on CT. Patients and methods. In a retrospective investigation, 124 indeterminate focal hepatic lesions in 96 patients were identified on CT examinations over 5 years from 1997 to 2001. All patients had MRI performed for the liver within 6 weeks of their CT examination. CT and MR images were reviewed independently by two separate groups of two radiologists. The value of MRI in characterizing these lesions was assessed. Diagnoses were confirmed based on histology, characteristic imaging features, and clinical follow-up . Results. MRI definitely characterized 73 lesions (58%) that were indeterminate on CT. MRI was accurate in 72/73 of these lesions. MRI could not definitely characterize 51 lesions (42%). Ten lesions were not visualized on MRI, and follow-up imaging confirmed that no lesion was present in eight of these cases (pseudolesions). Conclusion. MRI is valuable for the characterization of indeterminate focal hepatic lesions detected on CT.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/75168/1/13651820701216950.pd

    Is adenomyosis the neglected phenotype of an endomyometrial dysfunction syndrome?

    Get PDF
    Since the dissociation between adenomyoma and endometriosis in the 1920s and the laparoscopic progress in the diagnosis and surgery of endometriosis, the literature has been greatly focused on the disease endometriosis. The study of adenomyosis, on the other hand, has been neglected as the diagnosis remained based on hysterectomy specimens. However, since the introduction of magnetic resonance and sonographic imaging techniques in the 1980s, the myometrial junctional zone has been identified as a third uterine zone and interest in adenomyosis was renewed. This has also been the start for the interest in the role of the myometrial junctional zone dysfunction and adenomyosis in reproductive and obstetrical disorders

    Small primary adenocarcinoma in adenomyosis with nodal metastasis: a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malignant transformation of adenomyosis is a very rare event. Only about 30 cases of this occurrence have been documented till now.</p> <p>Case presentation</p> <p>The patient was a 57-year-old woman with a slightly enlarged uterus, who underwent total hysterectomy and unilateral adnexectomy. On gross inspection, the uterine wall displayed a single nodule measuring 5 cm and several small gelatinous lesions. Microscopic examination revealed a common leiomyoma and multiple adenomyotic foci. A few of these glands were transformed into a moderately differentiated adenocarcinoma. The endometrium was completely examined and tumor free. The carcinoma was, therefore, considered to be an endometrioid adenocarcinoma arising from adenomyosis. Four months later, an ultrasound scan revealed enlarged pelvic lymph nodes: a cytological diagnosis of metastatic adenocarcinoma was made.</p> <p>Immunohistochemical studies showed an enhanced positivity of the tumor site together with the neighbouring adenomyotic foci for estrogen receptors, aromatase, p53 and COX-2 expression when compared to the distant adenomyotic glands and the endometrium. We therefore postulate that the neoplastic transformation of adenomyosis implies an early carcinogenic event involving p53 and COX-2; further tumor growth is sustained by an autocrine-paracrine loop, based on a modulation of hormone receptors as well as aromatase and COX-2 local expression.</p> <p>Conclusion</p> <p>Adenocarcinoma in adenomyosis may be affected by local hormonal influence and, despite its small size, may metastasize.</p

    Cellular and molecular basis for endometriosis-associated infertility

    Full text link
    corecore