468 research outputs found
Isomeric states close to doubly magic Sn studied with JYFLTRAP
The double Penning trap mass spectrometer JYFLTRAP has been employed to
measure masses and excitation energies for isomers in Cd,
Cd, Cd and Te, for isomers in In and
In, and for isomers in Sn and Sb. These first
direct mass measurements of the Cd and In isomers reveal deviations to the
excitation energies based on results from beta-decay experiments and yield new
information on neutron- and proton-hole states close to Sn. A new
excitation energy of 144(4) keV has been determined for Cd. A good
agreement with the precisely known excitation energies of Cd,
Sn, and Sb has been found.Comment: 10 pages, 6 figures, submitted to Phys. Rev.
Measurement of parity-nonconserving rotation of neutron spin in the 0.734-eV p-wave resonance of
The parity nonconserving spin rotation of neutrons in the 0.734-eV p-wave
resonance of was measured with the neutron transmission method. Two
optically polarized cells were used before and behind a a 5-cm long
target as a polarizer and an analyzer of neutron spin. The rotation
angle was carefully measured by flipping the direction of polarization
in the polarizer in sequence. The peak-to-peak value of the spin rotation was
found to be rad/cm which was consistent with
the previous experiments. But the result was statisticallly improved. The s-p
mixing model gives the weak matrix element as meV. The
value agrees well with the one deduced from the parity-nonconserving
longitudinal asymmetry in the same resonance
Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V
The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and
46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8),
6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are
substantially improved in precision over previous results.Comment: 9 pages, 7 figures, 5 table
Electron-capture branch of 100Tc and tests of nuclear wave functions for double-beta decays
We present a measurement of the electron-capture branch of Tc. Our
value, , implies that the
Mo neutrino absorption cross section to the ground state of Tc
is roughly one third larger than previously thought. Compared to previous
measurements, our value of prevents a smaller disagreement with
QRPA calculations relevant to double- decay matrix elements
Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the -process calculations
The rare-earth peak in the -process abundance pattern depends sensitively
on both the astrophysical conditions and subtle changes in nuclear structure in
the region. This work takes an important step elucidating the nuclear structure
and reducing the uncertainties in -process calculations via precise atomic
mass measurements at the JYFLTRAP double Penning trap. Nd, Pm,
Sm, and Gd have been measured for the first time and the
precisions for Nd, Pm, Eu, Gd, and
Tb have been improved considerably. Nuclear structure has been probed
via two-neutron separation energies and neutron pairing energy metrics
. The data do not support the existence of a subshell closure at .
Neutron pairing has been found to be weaker than predicted by theoretical mass
models. The impact on the calculated -process abundances has been studied.
Substantial changes resulting in a smoother abundance distribution and a better
agreement with the solar -process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review
Letter
Parity Violation in Neutron Resonances in 107,109Ag
Parity nonconservation (PNC) was studied in p-wave resonances in Ag by measuring the helicity dependence of the neutron total cross section. Transmission measurements on natural Ag were performed in the energy range 32 to 422 eV with the time-of-flight method at the Manuel Lujan Neutron Scattering Center at Los Alamos National Laboratory. A total of 15 p-wave neutron resonances were studied in 107Ag and ninep-wave resonances in 109Ag. Statistically significant asymmetries were observed for eight resonances in 107Ag and for four resonances in109Ag. An analysis treating the PNC matrix elements as random variables yields a weak spreading width of Îw=(2.67-1.21+2.65)Ă10-7âeV for107Ag and Îw=(1.30-0.74+2.49)Ă10-7âeV for 109Ag
Parity Violation in Neutron Resonances in 115In
Parity nonconservation (PNC) was studied in p-wave resonances in indium by measuring the helicity dependence of the neutron total cross section in the neutron energy range 6.0â316 eV with the time-of-flight method at LANSCE. A total of 36 p-wave neutron resonances were studied in 115In, and statistically significant asymmetries were observed for nine cases. An analysis treating the PNC matrix elements as random variables yields a weak matrix element of M=(0.67-0.12+0.16)âmeV and a weak spreading width of Îw=(1.30-0.43+0.76)Ă10-7âeV
Theory of superconductor-insulator transition in single Josephson junctions
A non-band theory is developed to describe the superconductor-insulator (SI)
transtition in resistively shunted, single Josephson junctions. The
characteristic is formulated by a Landauer-like formula and evaluated by the
path-integral transfer-matrix method. The result is consistent with the recent
experiments at around 80 . However, the insulator phase shrinks with
decreasing temperature indicating that the single Josephson junction becomes
all superconducting at absolute zero temperature, as long as dissipation is
present.Comment: 4 pages, 3 figure
Assessing Cut-off Points of Eosinophils, Nasal Polyp, and Lund-Mackay Scores to Predict Surgery in Nasal Polyposis : A Real-World Study
Background: Developing tools to identify chronic rhinosinusitis with nasal polyps (CRSwNP) patients requiring surgical treatment would help clinicians treat patients more effectively. The aim of this retrospective cross-sectional study was to identify cut-off values for eosinophil percentage, nasal polyps (NP), and Lund-Mackay (LM) scores that may predict the need for surgical treatment in Finnish CRSwNP patients. Methods: Data of CRSwNP patients (N = 378) undergoing consultation for ESS in 2001-19 were used. Data was collected from patient records and Lund-Mackay scores were determined from sinus computed tomography scans. The percentage of eosinophils was microscopically evaluated from the polyp samples available (n = 81). Associations were analyzed by Mann Whitney U test, and cut-off values by the area under the receiver operating characteristic curve (AUROC). Results: ESS was performed to 293 (77.5%) of patients. Polyp eosinophilia was associated significantly with ESS (p = 0.001), whereas peripheral blood eosinophil count, LM- score and endoscopic NP- score were not (p > 0.05). AUROC values (95% CI) for detecting those needing ESS were for polyp eosinophilia 0.71 (0.60-0.83), p = 0.001, for LM score 0.59 (0.50-0.67), p = 0.054; for NP score 0.56 (0.48-0.64), p = 0.17, and for blood eosinophil count 0.68 (0.46-0.90), p = 0.08. With the threshold value of polyp eosinophilia (>25%), the sensitivity and specificity were optimal for detecting the group needing ESS from the group not undergoing ESS. The cut-off value of blood eosinophil count (>0.26 x 10(9)/L) had relatively good, yet statistically insignificant (underpowered), predictive potential. Moderate cut-off values were found for endoscopic LM score (>= 14/24) and NP score (>= 4/8). Conclusions: Polyp eosinophilia (>25%) predicted ESS among Finnish hospital-level CRSwNP patients. A future challenge would be to find less invasive and cost-effective clinical factors predicting uncontrolled CRSwNP.Peer reviewe
- âŠ