153 research outputs found

    Craniofacial Analysis May Indicate Co-Occurrence of Skeletal Malocclusions and Associated Risks in Development of Cleft Lip and Palate

    Get PDF
    Non-syndromic orofacial clefts encompass a range of morphological changes affecting the oral cavity and the craniofacial skeleton, of which the genetic and epigenetic etiologic factors remain largely unknown. The objective of this study is to explore the contribution of underlying dentofacial deformities (also known as skeletal malocclusions) in the craniofacial morphology of non-syndromic cleft lip and palate patients (nsCLP). For that purpose, geometric morphometric analysis was performed using full skull cone beam computed tomography (CBCT) images of patients with nsCLP (n = 30), normocephalic controls (n = 60), as well as to sex- and ethnicity- matched patients with an equivalent dentofacial deformity (n = 30). Our outcome measures were shape differences among the groups quantified via principal component analysis and associated principal component loadings, as well as mean shape differences quantified via a Procrustes distance among groups. According to our results, despite the shape differences among all three groups, the nsCLP group shares many morphological similarities in the maxilla and mandible with the dentofacial deformity group. Therefore, the dentoskeletal phenotype in nsCLP could be the result of the cleft and the coexisting dentofacial deformity and not simply the impact of the cleft

    Behavior of solutions of a third-order dynamic equation on time scales

    Get PDF
    In this paper, we will establish some sufficient conditions which guarantee that every solution of the third-order nonlinear dynamic equatio

    Effect of six weeks aerobic training upon blood trace metals levels

    Get PDF
    This study was carried out to investigate the effects of 6-week aerobic exercise program upon blood Zn and Cu levels. There were 12 male university students with an average age of 21.67 ± 0.89 years and no regular training habits participated in the study. The participants were subjected three days a week 1 hour a day continuous running program on treadmill with an intensity of 60-70% for a period of six weeks. They were fed with zinc and copper free diet throughout the study and it was made sure that they were not using copper or zinc containing vitamin tablets. The differences between the pre and post study periods were found to be statistically significant as regards to both resting and maximal loading conditions (p<0.01). The pre and post training max VO2 values were also found to be positively correlated with the copper and zinc levels in blood. Both the copper and zinc blood levels were significantly decreased after 6-week aerobic training period p<0.05. © Neuroendocrinology Letters

    Evaluation of biventricular myocardial performance index in patients with Behçet's disease

    Get PDF
    Objective: The global function of both left ventricular (LV) and right ventricular (RV) functions were compared in patients with Behçet's disease (BD) versus healthy controls. Methods: Biventricular function was evaluated by measurement of the myocardial performance index (MPI) evaluated from tissue Doppler echocardiographic measurements in 24 BD patients and was compared with measurements in 24 age- and sex-matched healthy controls. Results: Significantly higher MPI values were associated with ventricular dysfunction. The study demonstrated impaired RV function in patients with BD compared with healthy controls, whereas normal LV function was observed both in patients with BD and in healthy controls. Conclusion: Early noninvasive evaluation of the properties of BD during the asymptomatic phase of this inflammatory disease may have prognostic value in the management of patients. © 2012 Field House Publishing LLP

    Doping management for high-power fiber lasers: 100 W, few-picosecond pulse generation from an all-fiber-integrated amplifier

    Get PDF
    Thermal effects, which limit the average power, can be minimized by using low-doped, longer gain fibers, whereas the presence of nonlinear effects requires use of high-doped, shorter fibers to maximize the peak power. We propose the use of varying doping levels along the gain fiber to circumvent these opposing requirements. By analogy to dispersion management and nonlinearity management, we refer to this scheme as doping management. As a practical first implementation, we report on the development of a fiber laser-amplifier system, the last stage of which has a hybrid gain fiber composed of high-doped and low-doped Yb fibers. The amplifier generates 100 W at 100 MHz with pulse energy of 1 μJ. The seed source is a passively mode-locked fiber oscillator operating in the all-normaldispersion regime. The amplifier comprises three stages, which are all-fiber-integrated, delivering 13 ps pulses at full power. By optionally placing a grating compressor after the first stage amplifier, chirp of the seed pulses can be controlled, which allows an extra degree of freedom in the interplay between dispersion and self-phase modulation. This way, the laser delivers 4.5 ps pulses with ∼200 kW peak power directly from fiber, without using external pulse compression. © 2012 Optical Society of America

    Pre-formulation and systematic evaluation of amino acid assisted permeability of insulin across in vitro buccal cell layers

    Get PDF
    The aim of this work was to investigate alternative safe and effective permeation enhancers for buccal peptide delivery. Basic amino acids improved insulin solubility in water while 200 and 400 µg/mL lysine significantly increased insulin solubility in HBSS. Permeability data showed a significant improvement in insulin permeation especially for 10 µg/mL of lysine (p < 0.05) and 10 µg/mL histidine (p < 0.001), 100 µg/mL of glutamic acid (p < 0.05) and 200 µg/mL of glutamic acid and aspartic acid (p < 0.001) without affecting cell integrity; in contrast to sodium deoxycholate which enhanced insulin permeability but was toxic to the cells. It was hypothesized that both amino acids and insulin were ionised at buccal cavity pH and able to form stable ion pairs which penetrated the cells as one entity; while possibly triggering amino acid nutrient transporters on cell surfaces. Evidence of these transport mechanisms was seen with reduction of insulin transport at suboptimal temperatures as well as with basal-to-apical vectoral transport, and confocal imaging of transcellular insulin transport. These results obtained for insulin is the first indication of a possible amino acid mediated transport of insulin via formation of insulin-amino acid neutral complexes by the ion pairing mechanism

    Kinetic, Isotherm and Thermodynamic Analysis on Adsorption of Cr(VI) Ions from Aqueous Solutions by Synthesis and Characterization of Magnetic-Poly(divinylbenzene-vinylimidazole) Microbeads

    Get PDF
    The magnetic-poly(divinylbenzene-1-vinylimidazole) [m-poly(DVB-VIM)] microbeads (average diameter 53–212 μm) were synthesized and characterized; their use as adsorbent in removal of Cr(VI) ions from aqueous solutions was investigated. The m-poly(DVB-VIM) microbeads were prepared by copolymerizing of divinylbenzene (DVB) with 1-vinylimidazole (VIM). The m-poly(DVB-VIM) microbeads were characterized by N2 adsorption/desorption isotherms, ESR, elemental analysis, scanning electron microscope (SEM) and swelling studies. At fixed solid/solution ratio the various factors affecting adsorption of Cr(VI) ions from aqueous solutions such as pH, initial concentration, contact time and temperature were analyzed. Langmuir, Freundlich and Dubinin–Radushkvich isotherms were used as the model adsorption equilibrium data. Langmuir isotherm model was the most adequate. The pseudo-first-order, pseudo-second-order, Ritch-second-order and intraparticle diffusion models were used to describe the adsorption kinetics. The apparent activation energy was found to be 5.024 kJ mol−1, which is characteristic of a chemically controlled reaction. The experimental data fitted to pseudo-second-order kinetic. The study of temperature effect was quantified by calculating various thermodynamic parameters such as Gibbs free energy, enthalpy and entropy changes. The thermodynamic parameters obtained indicated the endothermic nature of adsorption of Cr(VI) ions. Morever, after the use in adsorption, the m-poly(DVB-VIM) microbeads with paramagnetic property were separeted via the applied magnetic force. The magnetic beads could be desorbed up to about 97% by treating with 1.0 M NaOH. These features make the m-poly(DVB-VIM) microbeads a potential candidate for support of Cr(VI) ions removal under magnetic field

    Guidelines for developing optical clocks with 101810^{-18} fractional frequency uncertainty

    Get PDF
    There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the 101810^{-18} range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with 1imes10181 imes 10^{-18} uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects
    corecore