390 research outputs found

    A Novel Autosomal Recessive GJA1 Missense Mutation Linked to Craniometaphyseal Dysplasia

    Get PDF
    Craniometaphyseal dysplasia (CMD) is a rare sclerosing skeletal disorder with progressive hyperostosis of craniofacial bones. CMD can be inherited in an autosomal dominant (AD) trait or occur after de novo mutations in the pyrophosphate transporter ANKH. Although the autosomal recessive (AR)form of CMD had been mapped to 6q21-22 the mutation has been elusive. In this study, we performed whole-exome sequencing for one subject with AR CMD and identified a novel missense mutation (c.716G>A, p.Arg239Gln) in the C-terminus of the gap junction protein alpha-1 (GJA1) coding for connexin 43 (Cx43). We confirmed this mutation in 6 individuals from 3 additional families. The homozygous mutation cosegregated only with affected family members. Connexin 43 is a major component of gap junctions in osteoblasts, osteocytes, osteoclasts and chondrocytes. Gap junctions are responsible for the diffusion of low molecular weight molecules between cells. Mutations in Cx43 cause several dominant and recessive disorders involving developmental abnormalities of bone such as dominant and recessive oculodentodigital dysplasia (ODDD; MIM #164200, 257850) and isolated syndactyly type III (MIM #186100), the characteristic digital anomaly in ODDD. However, characteristic ocular and dental features of ODDD as well as syndactyly are absent in patients with the recessive Arg239Gln Cx43 mutation. Bone remodeling mechanisms disrupted by this novel Cx43 mutation remain to be elucidated

    Finding the best efficiency for laser machining of gold colloids

    Get PDF

    Development and optimization of quantitative PCR for the diagnosis of invasive aspergillosis with bronchoalveolar lavage fluid

    Get PDF
    Background: The diagnosis of invasive pulmonary aspergillosis (IPA) remains challenging. Culture and histopathological examination of bronchoalveolar lavage (BAL) fluid are useful but have suboptimal sensitivity and in the case of culture may require several days for fungal growth to be evident. Detection of Aspergillus DNA in BAL fluid by quantitative PCR (qPCR) offers the potential for earlier diagnosis and higher sensitivity. It is important to adopt quality control measures in PCR assays to address false positives and negatives which can hinder accurate evaluation of diagnostic performance. Methods: BAL fluid from 94 episodes of pneumonia in 81 patients was analyzed. Thirteen episodes were categorized as proven or probable IPA using Mycoses Study Group criteria. The pellet and the supernatant fractions of the BAL were separately assayed. A successful extraction was confirmed with a human 18S rRNA gene qPCR. Inhibition in each qPCR was measured using an exogenous DNA based internal amplification control (IAC). The presence of DNA from pathogens in the Aspergillus genus was detected using qPCR targeting fungal 18S rRNA gene. Results: Human 18S rRNA gene qPCR confirmed successful DNA extraction of all samples. IAC detected some degree of initial inhibition in 11 samples. When culture was used to diagnose IPA, the sensitivity and specificity were 84.5% and 100% respectively. Receiver-operating characteristic analysis of qPCR showed that a cutoff of 13 fg of Aspergillus genomic DNA generated a sensitivity, specificity, positive and negative predictive value of 77%, 88%, 50%, 96% respectively. BAL pellet and supernatant analyzed together resulted in sensitivity and specificity similar to BAL pellet alone. Some patients did not meet standard criteria for IPA, but had consistently high levels of Aspergillus DNA in BAL fluid by qPCR. Conclusion: The Aspergillus qPCR assay detected Aspergillus DNA in 76.9% of subjects with proven or probable IPA when the concentrated BAL fluid pellet fraction was used for diagnosis. There was no benefit from analyzing the BAL supernatant fraction. Use of both extraction and amplification controls provided optimal quality control for interpreting qPCR results and therefore may increase our understanding of the true potential of qPCR for the diagnosis of IPA.Supported by NIH grant R01 AI054703 from the National Institute of Allergy and Infectious Diseases

    Factors associated with shunt dynamic in patients with cryptogenic stroke and patent foramen ovale: an observational cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As previously reported there is evidence for a reduction in right to left shunt (RLS) in stroke patients with patent foramen ovale (PFO). This occurs predominantly in patients with cryptogenic stroke (CS). We therefore analysed factors associated with a shunt reduction on follow-up in stroke patients suffering of CS.</p> <p>Methods</p> <p>On index event PFO and RLS were proven by transesophageal echocardiography and contrast-enhanced transcranial Doppler-sonography (ce-TCD). Silent PE was proved by ventilation perfusion scintigraphy (V/Q) within the stroke work-up on index event; all scans were re-evaluated in a blinded manner by two experts. The RLS was re-assessed on follow-up by ce-TCD. A reduction in shunt volume was defined as a difference of ≥20 microembolic signals (MES) or the lack of evidence of RLS on follow-up. For subsequent analyses patients with CS were considered; parameters such as deep vein thrombosis (DVT) and silent pulmonary embolism (PE) were analysed.</p> <p>Results</p> <p>In 39 PFO patients suffering of a CS the RLS was re-assessed on follow-up. In all patients (n = 39) with CS a V/Q was performed; the median age was 40 years, 24 (61.5%) patients were female. In 27 patients a reduction in RLS was evident. Silent PE was evident in 18/39 patients (46.2%). Factors such as atrial septum aneurysm, DVT or even silent PE were not associated with RLS dynamics. A greater time delay from index event to follow-up assessment was associated with a decrease in shunt volume (median 12 vs. 6 months, <it>p </it>= 0.013).</p> <p>Conclusions</p> <p>In patients with CS a reduction in RLS is not associated with the presence of a venous embolic event such as DVT or silent PE. A greater time delay between the initial and the follow-up investigation increases the likelihood for the detection of a reduction in RLS.</p

    Micro Structured Sensors for Neutron Detection

    Get PDF
    The shortage of 3He gas, identified as a problem several years ago, initiated research into alternative neutron detectors for various applications. One such technology is the microstructured semiconductor neutron detector (MSND). These compact detectors have microstructures etched deeply into the substrates that are subsequently backfilled with neutron reactive material. Single sided devices typically have thermal neutron detection efficiencies exceeding 30%, while double sided microstructured semiconductor neutron detectors (DS-MSND) have yielded \u3e69% thermal neutron detection efficiency. Both MSNDs and DS-MSNDs have been integrated into compact low-noise and low-power electronics modules. Dosimetry calculations indicate that these detectors can be used as active wearable neutron dosimeters. A discussion on the physics, performance and instrumentation of these MSNDs will be presented. The radiation environment in a nuclear reactor precludes the use of semiconductor detectors for in-core sensors, leading to the invention of another miniaturized neutron detector, the micro- pocket fission detector (MPFD). The detectors were developed for real time reactor power monitoring and also for pulse tracking for power excursion experiments. These miniaturized fission chambers have gas pockets on the order of 1 mm3 with a small concentration of uranium electrodeposited inside the gas chamber. The detectors are composed of radiation hard materials and assembled without adhesives. The small geometries can be assembled in arrays to transmit reactor power at various locations. Stable device operation was confirmed by testing under steady-state reactor conditions. Reactor power transients were observed in real-time. Design details and performance of MPFDs will be presented

    Phosphodiesterase 5 inhibitors lower both portal and pulmonary pressure in portopulmonary hypertension: a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Portopulmonary hypertension (PPHTN) is a severe complication in liver cirrhosis. PDE5 inhibitors lower pulmonary arterial pressure (PAP) in PPHTN. However, their effect on portal hypertension has not yet been investigated.</p> <p>Case presentation</p> <p>A 55 year old male patient presented with PPHTN and alcoholic liver cirrhosis. 10 mg of Tadalafil, a PDE5 inhibitor with a long half-life, was administered orally under continuous monitoring of pulmonary and portal hemodynamics. For maintenance therapy the patient received Sildenafil 20 mg bid.</p> <p>Tadalafil lowered mean PAP from 45 to 39 mmHg within 60 minutes. Cardiac output (CO) increased from 6.8 to 7.9 l/min. Central venous pressure (CVP) remained stable at 3 mmHg. Systolic and diastolic blood pressure was lowered from 167/89 to 159/86 mmHg. Pulse rate increased from 75 to 87 per min. Wedged hepatic vein pressure (WHVP) decreased from 21 to 18 mm Hg, hepatovenous pressure gradient (HVPG) decreased from 10 to 7 mmHg. Hemodynamic monitoring after 6 months of Sildenafil therapy revealed a sustained lowering of mean PAP. HVPG remained constant at 10 mmHg. Cardiac and pulmonary performance had further improved.</p> <p>Conclusion</p> <p>This case report shows for the first time, that phosphodiesterase 5 inhibitors lower both portal and pulmonary pressure in portopulmonary hypertension.</p

    Chronic Thromboembolic Pulmonary Hypertension

    Get PDF
    The pulmonary hypertension (PH) and right heart dysfunction that results from chronic thromboembolic involvement of the pulmonary vascular bed is potentially curable with surgical endarterectomy. Over the past several decades, growing clinical experience has brought about increased recognition of this treatable form of PH. Moreover, advances in cardiothoracic surgical techniques have given an increasing number of patients with chronic thromboembolic PH (CTEPH) a surgical remedy with decreasing perioperative morbidity and mortality risks. The availability of pulmonary hypertensive—specific medical therapy for CTEPH patients with surgically inaccessible disease also has been a positive therapeutic advance over the past several years. However, despite this progress, chronic thromboembolic disease as a sequela of acute pulmonary emboli continues to be underappreciated. Furthermore, even if CTEPH has been appropriately diagnosed, misinterpretation of diagnostic information may lead to the inappropriate exclusion of patients from surgical consideration. This may result in the prescription of pulmonary hypertensive medical therapy in CTEPH patients with potentially surgically correctable disease. This difficulty arises from a lack of objective criteria as to what constitutes surgical chronic thromboembolic disease, which primarily is a result of the variability in surgical experience in specialty centers in the United States. Consequently, clinicians must be wary about using pulmonary hypertensive medications in CTEPH patients. Before prescription, it is important to exclude patients from surgical consideration by consulting a specialized center with expertise in this discipline

    Acute pressure overload of the right ventricle. Comparison of two models of right-left shunt. Pulmonary artery to left atrium and right atrium to left atrium: experimental study

    Get PDF
    <p>Abtract</p> <p>Background</p> <p>In right ventricular failure (RVF), an interatrial shunt can relieve symptoms of severe pulmonary hypertension by reducing right ventricular preload and increasing systemic flow. Using a pig model to determine if a pulmonary artery - left atrium shunt (PA-LA) is better than a right atrial - left atrial shunt (RA-LA), we compared the hemodynamic effects and blood gases between the two shunts.</p> <p>Methods</p> <p>Thirty, male Large White pigs weighting in average 21.3 kg ± 0.7 (SEM) were divided into two groups (15 pigs per group): In group 1, banding of the pulmonary artery and a pulmonary artery to left atrium shunt with an 8 mm graft (PA-LA) was performed and in group 2 banding of the pulmonary artery and right atrial to left atrial shunt (RA-LA) with a similar graft was performed. Hemodynamic parameters and blood gases were measured from all cardiac chambers in 10 and 20 minutes, half and one hour interval from the baseline (30 min from the banding). Cardiac output and flow of at the left anterior descending artery was also monitored.</p> <p>Results</p> <p>In both groups, a stable RVF was generated. The PA-LA shunt compared to the RA-LA shunt has better hemodynamic performance concerning the decreased right ventricle afterload, the 4 fold higher mean pressure of the shunt, the better flow in left anterior descending artery and the decreased systemic vascular resistance. Favorable to the PA-LA shunt is also the tendency - although not statistically significant - in relation to central venous pressure, left atrial filling and cardiac output.</p> <p>Conclusion</p> <p>The PA-LA shunt can effectively reverse the catastrophic effects of acute RVF offering better hemodynamic characteristics than an interatrial shunt.</p
    corecore