297 research outputs found

    Paraxial propagation in amorphous optical media with screw dislocation

    Full text link
    We study paraxial beam propagation parallel to the screw axis of a dislocated amorphous medium that is optically weakly inhomogeneous and isotropic. The effect of the screw dislocation on the beam's orbital angular momentum is shown to change the optical vortex strength, rendering vortex annihilation or generation possible. Furthermore, the dislocation is shown to induce a weak \textit{biaxial} anisotropy in the medium due to the elasto-optic effect, which changes the beam's spin angular momentum as well as causing precession of the polarization. We derive the equations of motion of the beam and demonstrate the optical Hall effect in the dislocated medium. Its application with regard to determining the Burgers vector as well as the elasto-optic coefficients of the medium is explained

    Compositional homogeneity in a medical-grade stainless steel sintered with a Mn-Si additive

    Get PDF
    Cataloged from PDF version of article.In this paper, chemical composition uniformity in amorphous/nanocrystallization medical-grade stainless steel (ASTM ID: F2581) sintered with a Mn–Si additive was studied via scanning electron microscopy, energy dispersive X-ray spectroscopy, and transmission electron microscopy. The results show that as a result of sintering at 1000 °C, no dissociation of Mn–Si additive particles embedded in the stainless steel matrix occurs. In contrast, sintering at 1050 °C develops a relatively homogeneous microstructure from the chemical composition viewpoint. The aforementioned phenomena are explained by liquation of the Mn–Si eutectic additive, thereby wetting of the main powder particles, penetrating into the particle contacts and pore zones via capillary forces, and providing a path of high diffusivity. © 2012 Elsevier B.V. All rights reserved

    Fabrication of Nanostructured Medical-Grade Stainless Steel by Mechanical Alloying and Subsequent Liquid-Phase Sintering

    Get PDF
    Cataloged from PDF version of article.This article focuses on the microstructure of medical-grade P558 (ASTM F2581) stainless steel produced by mechanical alloying and liquid-phase sintering. Rietveld X-ray diffraction and transmission electron microscopy reflect that the mechanically alloyed stainless steel powder is a nanocrystal dispersed amorphous matrix composite.Mn-11.5 wt pct Si eutectic alloy as additive improves densification of the synthesized P558 alloy via liquid-phase sintering mechanism. X-ray mapping shows that after sintering at 1323 K (105°C) for 1 hour, a uniform distribution of dissolved Mn and Si is achieved. Moreover, the development of a nanostructured, fully austenitic stainless steel after sintering at the same temperature is realized by X-ray diffraction and transmission electron microscopy. © The Minerals, Metals & Materials Society and ASM International 201

    Federated mmWave Beam Selection Utilizing LIDAR Data

    Get PDF
    Efficient link configuration in millimeter wave (mmWave) communication systems is a crucial yet challenging task due to the overhead imposed by beam selection. For vehicle-to-infrastructure (V2I) networks, side information from LIDAR sensors mounted on the vehicles has been leveraged to reduce the beam search overhead. In this letter, we propose a federated LIDAR aided beam selection method for V2I mmWave communication systems. In the proposed scheme, connected vehicles collaborate to train a shared neural network (NN) on their locally available LIDAR data during normal operation of the system. We also propose a reduced-complexity convolutional NN (CNN) classifier architecture and LIDAR preprocessing, which significantly outperforms previous works in terms of both the performance and the complexity

    miR-608 rs4919510 C>G polymorphism decreased the risk of breast cancer in an Iranian subpopulation

    No full text
    Aim: MicroRNAs (miRNAs) are small noncoding RNAs that function as oncogene or tumor suppressors. The single nucleotide polymorphisms in miRNAs potentially can alter miRNA-binding sites on target genes as well as affecting miRNAs expression. The present study aimed to evaluate the impact of miR-608 rs4919510 C>G variant on breast cancer (BC) risk. Materials and Methods: This case-control study conducted on 160 women with BC and 192 age-matched healthy women. Genotyping of miR608 rs4919510 was done using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method. Results: Our findings showed that GC genotype significantly decreased the risk of BC (odds ratio (OR) = 0.49, 95% confidence interval (CI) 0.28–0.88, p = 0.018) compared to CC genotype. Furthermore the G allele decreased the risk of BC (OR = 0.53, 95%CI 0.30–0.92, p = 0.024). No significant association was found between miR-609 genotypes and clinicopathological characteristics of BC patients (p > 0.05). Conclusion: Our findings indicate that miR-608 polymorphism might be associated with decreased risk of BC in an Iranian subpopulation. Further large-scale studies with different ethnicities are needed to verify our findings

    Endothelial nitric oxide synthase gene Glu298Asp polymorphism and risk of preeclampsia in South East of Iran

    Get PDF
    Preeclampsia (PE) is the most serious complication of pregnancy that causes maternal and fetal morbidity and mortality. Although the exact pathophysiology of PE is unknown, a large number of studies have shown that abnormalities in nitric oxide (NO) synthesis may contribute to the development of this disorder. There are some evidences that polymorphisms of the endothelial nitric oxide synthase (eNOS) gene affect NO production and have been associated with hypertension and PE in some populations. Therefore the aim of this study was to assess the relation of the Glu298Asp eNOS polymorphism and PE in an Iranian population. We compared the frequency of the Glu298Asp polymorphism in 147 women with PE and 137 healthy pregnant control subjects by polymerase chain reaction- restriction fragment length polymorphism (PCR-RFLP) method. The frequencies of Glu298Asp genotypes were significantly different between PE women and controls (p < 0.001). The frequency of Asp allele was 0.32 in PE patients and 0.20 in controls and was significantly different (p < 0.001). The risk of PE was 2.4 fold in pregnant women with Asp allele. In conclusion, the Asp allele could be a risk factor for PE in South East of Iran.Key words: Nitric oxide synthase, polymorphism, preeclampsia, pregnancy

    Efficacy of the Biomaterials 3 wt%-nanostrontium-hydroxyapatite-enhanced Calcium Phosphate Cement (nanoSr-CPC) and nanoSr-CPC-incorporated Simvastatin-loaded Poly(lactic-co-glycolic-acid) Microspheres in Osteogenesis Improvement

    Get PDF
    Aims The purpose of this multi-phase explorative in vivo animal/surgical and in vitro multi-test experimental study was to (1) create a 3 wt%-nanostrontium hydroxyapatite-enhanced calcium phosphate cement (Sr-HA/CPC) for increasing bone formation and (2) creating a simvastatin-loaded poly(lactic-co-glycolic acid) (SIM-loaded PLGA) microspheres plus CPC composite (SIM-loaded PLGA + nanostrontium-CPC). The third goal was the extensive assessment of multiple in vitro and in vivo characteristics of the above experimental explorative products in vitro and in vivo (animal and surgical studies). Methods and results pertaining to Sr-HA/CPC Physical and chemical properties of the prepared Sr-HA/CPC were evaluated. MTT assay and alkaline phosphatase activities, and radiological and histological examinations of Sr-HA/CPC, CPC and negative control were compared. X-ray diffraction (XRD) indicated that crystallinity of the prepared cement increased by increasing the powder-to-liquid ratio. Incorporation of Sr-HA into CPC increased MTT assay (biocompatibility) and ALP activity (P \u3c 0.05). Histomorphometry showed greater bone formation after 4 weeks, after implantation of Sr-HA/CPC in 10 rats compared to implantations of CPC or empty defects in the same rats (n = 30, ANOVA P \u3c 0.05). Methods and results pertaining to SIM-loaded PLGA microspheres + nanostrontium-CPC composite After SEM assessment, the produced composite of microspheres and enhanced CPC were implanted for 8 weeks in 10 rabbits, along with positive and negative controls, enhanced CPC, and enhanced CPC plus SIM (n = 50). In the control group, only a small amount of bone had been regenerated (localized at the boundary of the defect); whereas, other groups showed new bone formation within and around the materials. A significant difference was found in the osteogenesis induced by the groups sham control (16.96 ± 1.01), bone materials (32.28 ± 4.03), nanostrontium-CPC (24.84 ± 2.6), nanostrontium-CPC-simvastatin (40.12 ± 3.29), and SIM-loaded PLGA + nanostrontium-CPC (44.8 ± 6.45) (ANOVA P \u3c 0.001). All the pairwise comparisons were significant (Tukey P \u3c 0.01), except that of nanostrontium-CPC-simvastatin and SIM-loaded PLGA + nanostrontium-CPC. This confirmed the efficacy of the SIM-loaded PLGA + nanostrontium-CPC composite, and its superiority over all materials except SIM-containing nanostrontium-CPC

    Ultra-low-dose non-contrast CT and CT angiography can be used interchangeably for assessing maximal abdominal aortic diameter

    Get PDF
    BACKGROUND: Routine CT scans may increasingly be used to document normal aortic size and to detect incidental abdominal aortic aneurysms. PURPOSE: To determine whether ultra-low-dose non-contrast CT (ULDNC-CT) can be used instead of the gold standard CT angiography (CTA) for assessment of maximal abdominal aortic diameter. MATERIALS AND METHODS: This retrospective study included 50 patients who underwent CTA and a normal-dose non–contrast CT for suspected renal artery stenosis. ULDNC-CT datasets were generated from the normal-dose non–contrast CT datasets using a simulation technique. Using the centerline technique, radiology consultants (n = 4) and residents (n = 3) determined maximal abdominal aortic diameter. The limits of agreement with the mean (LOAM) was used to access observer agreement. LOAM represents how much a measurement by a single observer may plausibly deviate from the mean of all observers on the specific subject. RESULTS: Observers completed 1400 measurements encompassing repeated CTA and ULDNC-CT measurements. The mean diameter was 24.0 and 25.0 mm for CTA and ULDNC-CT, respectively, yielding a significant but minor mean difference of 1.0 mm. The 95% LOAM reproducibility was similar for CTA and ULDNC-CT (2.3 vs 2.3 mm). In addition, the 95% LOAM and mean diameters were similar for CTA and ULDNC-CT when observers were grouped as consultants and residents. CONCLUSIONS: Ultra-low-dose non–contrast CT exhibited similar accuracy and reproducibility of measurements compared with CTA for assessing maximal abdominal aortic diameter supporting that ULDNC-CT can be used interchangeably with CTA in the lower range of aortic sizes
    corecore