244 research outputs found

    Low specificity of determine HIV1/2 RDT using whole blood in south west Tanzania

    Get PDF
    Objective: To evaluate the diagnostic performance of two rapid detection tests (RDTs) for HIV 1/2 in plasma and in whole blood samples. Methods: More than 15,000 study subjects above the age of two years participated in two rounds of a cohort study to determine the prevalence of HIV. HIV testing was performed using the Determine HIV 1/2 test (Abbott) in the first (2006/2007) and the HIV 1/2 STAT-PAK Dipstick Assay (Chembio) in the second round (2007/2008) of the survey. Positive results were classified into faint and strong bands depending on the visual appearance of the test strip and confirmed by ELISA and Western blot. Results: The sensitivity and specificity of the Determine RDT were 100% (95% confidence interval = 86.8 to 100%) and 96.8% (95.9 to 97.6%) in whole blood and 100% (99.7 to 100%) and 97.9% (97.6 to 98.1%) in plasma respectively. Specificity was highly dependent on the tested sample type: when using whole blood, 67.1% of positive results were false positive, as opposed to 17.4% in plasma. Test strips with only faint positive bands were more often false positive than strips showing strong bands and were more common in whole blood than in plasma. Evaluation of the STAT-PAK RDT in plasma during the second year resulted in a sensitivity of 99.7% (99.1 to 99.9%) and a specificity of 99.3% (99.1 to 99.4%) with 6.9% of the positive results being false. Conclusions: Our study shows that the Determine HIV 1/2 strip test with its high sensitivity is an excellent tool to screen for HIV infection, but that – at least in our setting – it can not be recommended as a confirmatory test in VCT campaigns where whole blood is used

    The East Greenland Coastal Current : structure, variability, and forcing

    Get PDF
    Author Posting. © Elsevier B.V. , 2008. This is the author's version of the work. It is posted here by permission of Elsevier B.V. for personal use, not for redistribution. The definitive version was published in Progress In Oceanography 78 (2008): 58-77, doi:10.1016/j.pocean.2007.09.006.The subtidal circulation of the southeast Greenland shelf is described using a set of high-resolution hydrographic and velocity transects occupied in summer 2004. The main feature is the East Greenland Coastal Current (EGCC), a low-salinity, high-velocity jet with a wedge-shaped hydrographic structure characteristic of other surface buoyancydriven currents. The EGCC was observed along the entire Greenland shelf south of Denmark Strait, while the transect north of the strait showed only a weak shelf flow. This observation, in conjunction with water mass considerations and other supporting evidence, suggests that the EGCC is an inner branch of the East Greenland Current (EGC) that forms south of Denmark Strait. It is argued that bathymetric steering is the most likely reason why the EGC apparently bifurcates at this location. Repeat sections occupied at Cape Farewell between 1997 and 2004 show that the alongshelf wind stress can have a strong influence on the structure and strength of the EGCC and EGC on timescales of 2-3 days. Accounting for the wind-induced effects, the volume transport of the combined EGCC/EGC system is roughly constant (~2 Sv) over the study domain, from 68°N to Cape Farewell near 60°N. The corresponding freshwater transport increases by roughly 60% over this distance (59 to 96 mSv, referenced to a salinity of 34.8). This trend is consistent with a simple freshwater budget of the EGCC/EGC system that accounts for meltwater runoff, melting sea-ice and icebergs, and net precipitation minus evaporation.This work was funded by the National Science Foundation grant OCE-0450658. DS was also partially supported by the Woods Hole Oceanographic Institution Academic Programs Office

    Pleural fluid soluble triggering receptor expressed on myeloid cells-1 as a marker of bacterial infection: a meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pleural infection is a common clinical problem. Its successful treatment depends on rapid diagnosis and early initiation of antibiotics. The measurement of soluble triggering receptor expressed in myeloid cells-1 (sTREM-1) level in pleural effusions has proven to be a valuable diagnostic tool for differentiating bacterial effusions from effusions of other etiologies. Herein, we performed a meta-analysis to assess the accuracy of pleural fluid sTREM-1 in the diagnosis of bacterial infection.</p> <p>Methods</p> <p>We searched Web of Knowledge and Medline from 1990 through March 2011 for studies reporting diagnostic accuracy data regarding the use of sTREM-1 in the diagnosis of bacterial pleural effusions. Pooled sensitivity and specificity and summary measures of accuracy and Q* were calculated.</p> <p>Results</p> <p>Overall, the sensitivity of sTREM-1was 78% (95% CI: 72%-83%); the specificity was 84% (95% CI: 80%-87%); the positive likelihood ratio was 6.0 (95% CI: 3.3-10.7); and the negative likelihood ratio was 0.22 (95% CI: 0.12-0.40). The area under the SROC curve for sTREM-1 was 0.92. Statistical heterogeneity and inconsistency were found for sensitivity (p = 0.015, χ<sup>2 </sup>= 15.73, I<sup>2 </sup>= 61.9%), specificity (p = 0.000, χ<sup>2 </sup>= 29.90, I<sup>2 </sup>= 79.9%), positive likelihood ratio (p = 0.000, χ<sup>2 </sup>= 33.09, I<sup>2 </sup>= 81.9%), negative likelihood ratio (p = 0.008, χ<sup>2 </sup>= 17.25, I<sup>2 </sup>= 65.2%), and diagnostic odds ratio (p = 0.000, χ<sup>2 </sup>= 28.49, I<sup>2 </sup>= 78.9%). A meta-regression analysis performed showed that the Quality Assessment of Diagnostic Accuracy Studies score (p = 0.3245; RDOR, 4.34; 95% CI, 0.11 to 164.01), the Standards for Reporting of Diagnostic Accuracy score (p = 0.3331; RDOR, 1.70; 95% CI, 0.44 to 6.52), lack of blinding (p = 0.7439; RDOR, 0.60; 95% CI, 0.01 to 33.80), and whether the studies were prospective or retrospective studies (p = 0.2068; RDOR, 7.44; 95% CI, 0.18 to 301.17) did not affect the test accuracy. A funnel plot for publication bias suggested a remarkable trend of publication bias.</p> <p>Conclusions</p> <p>Our findings suggest that sTREM-1 has a good diagnostic accuracy and may provide a useful adjunctive tool for the diagnosis of bacterial pleural effusions. However, further studies are needed in order to identify any differences in the diagnostic performance of sTREM-1 of parapneumonic effusions and empyemas.</p

    Silver hake tracks changes in Northwest Atlantic circulation

    Get PDF
    Author Posting. © The Author(s), 2011. This is the author's version of the work. It is posted here by permission of Nature Publishing Group for personal use, not for redistribution. The definitive version was published in Nature Communications 2 (2011): 412, doi:10.1038/ncomms1420.Recent studies documenting shifts in spatial distribution of many organisms in response to a warming climate highlight the need to understand the mechanisms underlying species distribution at large spatial scales. Here we present one noteworthy example of remote oceanographic processes governing the spatial distribution of adult silver hake, Merluccius bilinearis, a commercially important fish in the Northeast US shelf region. Changes in spatial distribution of silver hake over the last 40 years are highly correlated with the position of the Gulf Stream (GS). These changes in distribution are in direct response to local changes in bottom temperature on the continental shelf that are responding to the same large scale circulation change affecting the GS path, namely changes in the Atlantic Meridional Overturning Circulation (AMOC). If AMOC weakens as is suggested by global climate models, silver hake distribution will remain in a poleward position, the extent to which could be forecast at both decadal and multidecadal scales.J.A.N. was supported by the NOAA Fisheries and the Environment program (FATE). T.M.J. and Y.O.K. were supported by the WHOI Ocean Climate Change Institute and Ocean Life Institute

    Long-Term Effects of Autologous Bone Marrow Stem Cell Treatment in Acute Myocardial Infarction: Factors That May Influence Outcomes

    Get PDF
    AIMS: To investigate whether there are important sources of heterogeneity between the findings of different clinical trials which administer autologous stem cell treatment for acute myocardial infarction (AMI) and to evaluate what factors may influence the long-term effects of this treatment. METHODS AND RESULTS: MEDLINE (1950-January 2011), EMBASE (1974-January 2011), CENTRAL (The Cochrane Library 2011, Issue 1), CINAHL (1982-January 2011), and ongoing trials registers were searched for randomised trials of bone marrow stem cells as treatment for AMI. Hand-searching was used to screen recent, relevant conference proceedings (2005-2010/11). Meta-analyses were conducted using random-effects models and heterogeneity between subgroups was assessed using chi-squared tests. Planned analyses included length of follow-up, timing of cell infusion and dose, patient selection, small trial size effect, methodological quality, loss of follow-up and date of publication. Thirty-three trials with a total of 1,765 participants were included. There was no evidence of bias due to publication or time-lag, methodological quality of included studies, participant drop-out, duration of follow-up or date of the first disclosure of results. However, in long-term follow-ups the treatment seemed more effective when administered at doses greater than 10(8) cells and to patients with more severe heart dysfunction. CONCLUSIONS: Evaluation of heterogeneity between trials has not identified significant sources of bias in this study. However, clinical differences between trials are likely to exist which should be considered when undertaking future trials

    Low sensitivity of a urine LAM-ELISA in the diagnosis of pulmonary tuberculosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The development and evaluation of rapid and accurate new diagnostic tools is essential to improve tuberculosis (TB) control in developing countries. In a previous study, the first release of a urine LAM-ELISA by Chemogen (Portland, USA) has been evaluated with a promising sensitivity and specificity for the diagnosis of pulmonary TB. In the present study, the now commercially available assay has been clinically assessed regarding its diagnostic value alone and in combination with clinical co-factors.</p> <p>Methods</p> <p>The test was applied to two urine samples from 291 consecutively enrolled Tanzanian patients with suspected pulmonary tuberculosis. The participants were subsequently assigned to classification groups according to microbiological, clinical and radiological findings at recruitment and during a maximum follow up period of 56 days.</p> <p>Results</p> <p>Only 35 out of 69 pulmonary TB cases -confirmed by smear microscopy and/or solid culture and/or liquid culture- showed at least one positive LAM-ELISA result (sensitivity 50.7%). The sensitivity was noticeably higher in females (66.7%) and in HIV positive participants (62.0%). The specificity amounted to 87.8% and was determined in participants with negative results in all microbiological tests and with sustained recovery under antibiotic treatment at day 56. Correlation with urinalysis revealed that proteinuria was significantly and positively associated with LAM-positivity (<it>P </it>= 0.026).</p> <p>Conclusion</p> <p>This commercially available generation of LAM-ELISA does not appear to be useful as an independent diagnostic test for pulmonary tuberculosis. The question whether the assay is suitable as a supplemental device in the diagnosis of HIV-associated TB, requires further investigations.</p
    • …
    corecore