1,248 research outputs found

    Characterization of health care utilization in patients receiving implantable cardioverter-defibrillator therapies: An analysis of the managed ventricular pacing trial.

    Get PDF
    BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are effective in terminating lethal arrhythmias, but little is known about the degree of health care utilization (HCU) after ICD therapies. OBJECTIVE: Using data from the managed ventricular pacing trial, we sought to identify the incidence and types of HCU in ICD patients after receiving ICD therapy (shocks or antitachycardia pacing [ATP]). METHODS: We analyzed HCU events (ventricular tachyarrhythmia [VTA]-related, heart failure-related, ICD implant procedure-related, ICD system-related, or other) and their association with ICD therapies (shocked ventricular tachycardia episode, ATP-terminated ventricular tachycardia episode, and inappropriately shocked episode). RESULTS: A total of 1879 HCUs occurred in 695 of 1030 subjects (80% primary prevention) and were classified as follows: 133 (7%) VTA-related, 373 (20%) heart failure-related, 97 (5%) implant procedure-related, 115 (6%) system-related, and 1160 (62%) other. Of 2113 treated VTA episodes, 1680 (80%) received ATP only and 433 (20%) received shocks. Stratifying VTA-related HCUs on the basis of the type of ICD therapy delivered, there were 25 HCUs per 100 shocked VTA episodes compared with 1 HCU per 100 ATP-terminated episodes. Inappropriate ICD shocks occurred in 8.7% of the subjects and were associated with 115 HCUs. The majority of HCUs (52%) began in the emergency department, and 66% of all HCUs resulted in hospitalization. CONCLUSION: For VTA-related HCUs, shocks are associated with a 25-fold increase in HCUs compared to VTAs treated by ATP only. Application of evidence-based strategies and automated device-based algorithms to reduce ICD shocks (higher rate cutoffs, use of ATP, and arrhythmia detection) may help reduce HCUs

    Current rectification by simple molecular quantum dots: an ab-initio study

    Full text link
    We calculate a current rectification by molecules containing a conjugated molecular group sandwiched between two saturated (insulating) molecular groups of different length (molecular quantum dot) using an ab-initio non-equilibrium Green's function method. In particular, we study S-(CH2)m-C10H6-(CH2)n-S dithiol with Naphthalene as a conjugated central group. The rectification current ratio ~35 has been observed at m = 2 and n = 10, due to resonant tunneling through the molecular orbital (MO) closest to the electrode Fermi level (lowest unoccupied MO in the present case). The rectification is limited by interference of other conducting orbitals, but can be improved by e.g. adding an electron withdrawing group to the naphthalene.Comment: 8 pages, 9 figure

    Boosting Long-term Memory via Wakeful Rest: Intentional Rehearsal is not Necessary, Automatic Consolidation is Sufficient.

    Get PDF
    <div><p>People perform better on tests of delayed free recall if learning is followed immediately by a short wakeful rest than by a short period of sensory stimulation. Animal and human work suggests that wakeful resting provides optimal conditions for the consolidation of recently acquired memories. However, an alternative account cannot be ruled out, namely that wakeful resting provides optimal conditions for intentional rehearsal of recently acquired memories, thus driving superior memory. Here we utilised non-recallable words to examine whether wakeful rest boosts long-term memory, even when new memories could not be rehearsed intentionally during the wakeful rest delay. The probing of non-recallable words requires a recognition paradigm. Therefore, we first established, via Experiment 1, that the rest-induced boost in memory observed via free recall can be replicated in a recognition paradigm, using concrete nouns. In Experiment 2, participants heard 30 non-recallable non-words, presented as ‘foreign names in a bridge club abroad’ and then either rested wakefully or played a visual spot-the-difference game for 10 minutes. Retention was probed via recognition at two time points, 15 minutes and 7 days after presentation. As in Experiment 1, wakeful rest boosted recognition significantly, and this boost was maintained for at least 7 days. Our results indicate that the enhancement of memory via wakeful rest is <i>not</i> dependent upon intentional rehearsal of learned material during the rest period. We thus conclude that consolidation is <i>sufficient</i> for this rest-induced memory boost to emerge. We propose that wakeful resting allows for superior memory consolidation, resulting in stronger and/or more veridical representations of experienced events which can be detected via tests of free recall and recognition.</p></div

    Rate-equation calculations of the current flow through two-site molecular device and DNA-based junction

    Full text link
    Here we present the calculations of incoherent current flowing through the two-site molecular device as well as the DNA-based junction within the rate-equation approach. Few interesting phenomena are discussed in detail. Structural asymmetry of two-site molecule results in rectification effect, which can be neutralized by asymmetric voltage drop at the molecule-metal contacts due to coupling asymmetry. The results received for poly(dG)-poly(dC) DNA molecule reveal the coupling- and temperature-independent saturation effect of the current at high voltages, where for short chains we establish the inverse square distance dependence. Besides, we document the shift of the conductance peak in the direction to higher voltages due to the temperature decrease.Comment: 12 pages, 6 figure

    Initial Independent Outcomes from Focal Impulse and Rotor Modulation Ablation for Atrial Fibrillation: Multicenter FIRM Registry

    Get PDF
    Introduction The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. Methods We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View™; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. Results Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145–354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). Conclusions Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center’s first cases

    The Concussion Recognition Tool 5th Edition (CRT5): Background and rationale

    Get PDF
    The Concussion Recognition Tool 5 (CRT5) is the most recent revision of the Pocket Sport Concussion Assessment Tool 2 that was initially introduced by the Concussion in Sport Group in 2005. The CRT5 is designed to assist non-medically trained individuals to recognise the signs and symptoms of possible sport-related concussion and provides guidance for removing an athlete from play/sport and to seek medical attention. This paper presents the development of the CRT5 and highlights the differences between the CRT5 and prior versions of the instrument

    Implementation of the 2017 Berlin Concussion in Sport Group Consensus Statement in contact and collision sports: a joint position statement from 11 national and international sports organisations.

    Get PDF
    The 2017 Berlin Concussion in Sport Group Consensus Statement provides a global summary of best practice in concussion prevention, diagnosis and management, underpinned by systematic reviews and expert consensus. Due to their different settings and rules, individual sports need to adapt concussion guidelines according to their specific regulatory environment. At the same time, consistent application of the Berlin Consensus Statement's themes across sporting codes is likely to facilitate superior and uniform diagnosis and management, improve concussion education and highlight collaborative research opportunities. This document summarises the approaches discussed by medical representatives from the governing bodies of 10 different contact and collision sports in Dublin, Ireland in July 2017. Those sports are: American football, Australian football, basketball, cricket, equestrian sports, football/soccer, ice hockey, rugby league, rugby union and skiing. This document had been endorsed by 11 sport governing bodies/national federations at the time of being published

    3D Anatomy of the Atrioventricular Conduction Axis Reconstructed Relative to Gross Anatomical Landmarks Using Hierarchical Phase-contrast Tomography

    Get PDF
    \ua9 The Author(s) 2025. Anatomical investigations aiming to delineate the 3D anatomy of the conduction system have been limited. Hierarchical phase-contrast tomography now provides the ability for 3D imaging at the micron-level spatial resolution. In this report, we present 3D reconstructions of the atrioventricular conduction axis within a structurally normal autopsied heart
    corecore