96 research outputs found
Approximate Particle Number Projection for Rotating Nuclei
Pairing correlations in rotating nuclei are discussed within the
Lipkin-Nogami method. The accuracy of the method is tested for the
Krumlinde-Szyma\'nski R(5) model. The results of calculations are compared with
those obtained from the standard mean field theory and particle-number
projection method, and with exact solutions.Comment: 15 pages, 6 figures available on request, REVTEX3.
Recommended from our members
SEIS: Insight's Seismic Experiment for Internal Structure of Mars.
By the end of 2018, 42 years after the landing of the two Viking seismometers on Mars, InSight will deploy onto Mars' surface the SEIS (Seismic Experiment for Internal Structure) instrument; a six-axes seismometer equipped with both a long-period three-axes Very Broad Band (VBB) instrument and a three-axes short-period (SP) instrument. These six sensors will cover a broad range of the seismic bandwidth, from 0.01 Hz to 50 Hz, with possible extension to longer periods. Data will be transmitted in the form of three continuous VBB components at 2 sample per second (sps), an estimation of the short period energy content from the SP at 1 sps and a continuous compound VBB/SP vertical axis at 10 sps. The continuous streams will be augmented by requested event data with sample rates from 20 to 100 sps. SEIS will improve upon the existing resolution of Viking's Mars seismic monitoring by a factor of ∼ 2500 at 1 Hz and ∼ 200 000 at 0.1 Hz. An additional major improvement is that, contrary to Viking, the seismometers will be deployed via a robotic arm directly onto Mars' surface and will be protected against temperature and wind by highly efficient thermal and wind shielding. Based on existing knowledge of Mars, it is reasonable to infer a moment magnitude detection threshold of M w ∼ 3 at 40 ∘ epicentral distance and a potential to detect several tens of quakes and about five impacts per year. In this paper, we first describe the science goals of the experiment and the rationale used to define its requirements. We then provide a detailed description of the hardware, from the sensors to the deployment system and associated performance, including transfer functions of the seismic sensors and temperature sensors. We conclude by describing the experiment ground segment, including data processing services, outreach and education networks and provide a description of the format to be used for future data distribution.Electronic supplementary materialThe online version of this article (10.1007/s11214-018-0574-6) contains supplementary material, which is available to authorized users
The Value of Rents and the Likelihood of Conflicts
This paper extends the prey--predator model of Grossman and Kim (1995) to analyze the relation between the value of the contested rent and the emergence of a conflict. We show that an increase in the value of the rent makes the conflict equilibrium more likely. We also analyze the case where the valuation of the rent is different for the two players. We find, for example, that a conflict equilibrium may occur even though the predator has an important disadvantage in warfare. That's when its valuation of the rent is sufficiently high compare to that of the prey
Biomarkers of Multiple Sclerosis
The search for an ideal multiple sclerosis biomarker with good diagnostic value, prognostic reference and an impact on clinical outcome has yet to be realized and is still ongoing. The aim of this review is to establish an overview of the frequent biomarkers for multiple sclerosis that exist to date. The review summarizes the results obtained from electronic databases, as well as thorough manual searches. In this review the sources and methods of biomarkers extraction are described; in addition to the description of each biomarker, determination of the prognostic, diagnostic, disease monitoring and treatment response values besides clinical impact they might possess. We divided the biomarkers into three categories according to the achievement method: laboratory markers, genetic-immunogenetic markers and imaging markers. We have found two biomarkers at the time being considered the gold standard for MS diagnostics. Unfortunately, there does not exist a single solitary marker being able to present reliable diagnostic value, prognostic value, high sensitivity and specificity as well as clinical impact. We need more studies to find the best biomarker for MS.publishersversionPeer reviewe
SEIS: Insight’s Seismic Experiment for Internal Structure of Mars
By the end of 2018, 42 years after the landing of the two Viking seismometers
on Mars, InSight will deploy onto Mars’ surface the SEIS (Seismic Experiment for Internal
Structure) instrument; a six-axes seismometer equipped with both a long-period three-axes
Very Broad Band (VBB) instrument and a three-axes short-period (SP) instrument. These
six sensors will cover a broad range of the seismic bandwidth, from 0.01 Hz to 50 Hz,
with possible extension to longer periods. Data will be transmitted in the form of three
continuous VBB components at 2 sample per second (sps), an estimation of the short period
energy content from the SP at 1 sps and a continuous compound VBB/SP vertical axis at
10 sps. The continuous streams will be augmented by requested event data with sample
rates from 20 to 100 sps. SEIS will improve upon the existing resolution of Viking’s Mars
seismic monitoring by a factor of ∼ 2500 at 1 Hz and ∼ 200 000 at 0.1 Hz. An additional
major improvement is that, contrary to Viking, the seismometers will be deployed via a
robotic arm directly onto Mars’ surface and will be protected against temperature and wind
by highly efficient thermal and wind shielding. Based on existing knowledge of Mars, it is
reasonable to infer a moment magnitude detection threshold of Mw ∼ 3 at 40◦ epicentral
distance and a potential to detect several tens of quakes and about five impacts per year. In
this paper, we first describe the science goals of the experiment and the rationale used to
define its requirements. We then provide a detailed description of the hardware, from the
sensors to the deployment system and associated performance, including transfer functions
of the seismic sensors and temperature sensors. We conclude by describing the experiment
ground segment, including data processing services, outreach and education networks and
provide a description of the format to be used for future data distribution
A gait retraining system using augmented-reality to modify footprint parameters: Effects on lower-limb sagittal-plane kinematics.
Improving lower-limb flexion/extension angles during walking is important for the treatment of numerous pathologies. Currently, these gait retraining procedures are mostly qualitative, often based on visual assessment and oral instructions. This study aimed to propose an alternative method combining motion capture and display of target footprints on the floor. The second objectives were to determine the error in footprint modifications and the effects of footprint modifications on lower-limb flexion/extension angles. An augmented-reality system made of an optoelectronic motion capture device and video projectors displaying target footprints on the floor was designed. 10 young healthy subjects performed a series of 27 trials, consisting of increased and decreased amplitudes in stride length, step width and foot progression angle. 11 standard features were used to describe and compare lower-limb flexion/extension angles among footprint modifications. Subjects became accustomed to walk on target footprints in less than 10 min, with mean (± SD) precision of 0.020 ± 0.002 m in stride length, 0.022 ± 0.006 m in step width, and 2.7 ± 0.6° in progression angle. Modifying stride length had significant effects on 3/3 hip, 2/4 knee and 4/4 ankle features. Similarly, step width and progression angle modifications affected 2/3 and 1/3 hip, 2/4 and 1/4 knee as well as 3/4 and 2/4 ankle features, respectively. In conclusion, this study introduced an augmented-reality method allowing healthy subjects to modify their footprint parameters rapidly and precisely. Walking with modified footprints changed lower-limb sagittal-plane kinematics. Further research is needed to design rehabilitation protocols for specific pathologies
- …