365 research outputs found
Correlations of structural, magnetic, and dielectric properties of undoped and doped CaCu3Ti4O12
The present work reports synthesis, as well as a detailed and careful
characterization of structural, magnetic, and dielectric properties of
differently tempered undoped and doped CaCu3Ti4O12 (CCTO) ceramics. For this
purpose, neutron and x-ray powder diffraction, SQUID measurements, and
dielectric spectroscopy have been performed. Mn-, Fe-, and Ni-doped CCTO
ceramics were investigated in great detail to document the influence of
low-level doping with 3d metals on the antiferromagnetic structure and
dielectric properties. In the light of possible magnetoelectric coupling in
these doped ceramics, the dielectric measurements were also carried out in
external magnetic fields up to 7 T, showing a minor but significant dependence
of the dielectric constant on the applied magnetic field. Undoped CCTO is
well-known for its colossal dielectric constant in a broad frequency and
temperature range. With the present extended characterization of doped as well
as undoped CCTO, we want to address the question why doping with only 1% Mn or
0.5% Fe decreases the room-temperature dielectric constant of CCTO by a factor
of ~100 with a concomitant reduction of the conductivity, whereas 0.5% Ni
doping changes the dielectric properties only slightly. In addition,
diffraction experiments and magnetic investigations were undertaken to check
for possible correlations of the magnitude of the colossal dielectric constants
with structural details or with magnetic properties like the magnetic ordering,
the Curie-Weiss temperatures, or the paramagnetic moment. It is revealed, that
while the magnetic ordering temperature and the effective moment of all
investigated CCTO ceramics are rather similar, there is a dramatic influence of
doping and tempering time on the Curie-Weiss constant.Comment: 10 pages, 11 figure
GATE : a simulation toolkit for PET and SPECT
Monte Carlo simulation is an essential tool in emission tomography that can
assist in the design of new medical imaging devices, the optimization of
acquisition protocols, and the development or assessment of image
reconstruction algorithms and correction techniques. GATE, the Geant4
Application for Tomographic Emission, encapsulates the Geant4 libraries to
achieve a modular, versatile, scripted simulation toolkit adapted to the field
of nuclear medicine. In particular, GATE allows the description of
time-dependent phenomena such as source or detector movement, and source decay
kinetics. This feature makes it possible to simulate time curves under
realistic acquisition conditions and to test dynamic reconstruction algorithms.
A public release of GATE licensed under the GNU Lesser General Public License
can be downloaded at the address http://www-lphe.epfl.ch/GATE/
Mise en place de la Maîtrise Statistique des Procédés pour les contrôles pré-traitement par imagerie portale pour la technique VMAT
National audienc
Unusual cause of severe toxic methemoglobinemia in an infant: a case report
Toxic methemoglobinemia is an uncommon blood disorder induced by exposure to certain oxidizing agents and drugs. In severe cases, this condition may rapidly lead to major cardiopulmonary compromise and constitutes an emergency requiring prompt recognition and early management. We report an unusual case of severe toxic methemoglobinemia following wide cutaneous application of a pomade containing benzocaine, resorcin, and oxyquinoline (Nestosyl®) in an infant
Design of experiments in medical physics: Application to the AAA beam model validation
Purpose
The purpose of this study is to evaluate the usefulness of the design of experiments in the analysis of multiparametric problems related to the quality assurance in radiotherapy. The main motivation is to use this statistical method to optimize the quality assurance processes in the validation of beam models.
Method
Considering the Varian Eclipse system, eight parameters with several levels were selected: energy, MLC, depth, X, Y1 and Y2 jaw dimensions, wedge and wedge jaw. A Taguchi table was used to define 72 validation tests. Measurements were conducted in water using a CC04 on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a 2300IX accelerator matched by the vendor. Dose was computed using the AAA algorithm. The same raw data was used for all accelerators during the beam modelling.
Results
The mean difference between computed and measured doses was 0.1 ± 0.5% for all beams and all accelerators with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all accelerators. The energy was found to be an influencing parameter but the deviations observed were smaller than 1% and not considered clinically significant.
Conclusion
Designs of experiment can help define the optimal measurement set to validate a beam model. The proposed method can be used to identify the prognostic factors of dose accuracy. The beam models were validated for the 4 accelerators which were found dosimetrically equivalent even though the accelerator characteristics differ
A new robust statistical method for treatment planning systems validation using experimental designs
Introduction
Dose computation verification is an important part of acceptance testing. The IAEA Tecdoc 1540 and 1583 suggest comparing computed dose to measurements for several beam configurations. However, this process is time-consuming and results out of tolerance are often left unexplained.
Purpose
To validate a treatment planning system using experimental designs which allow evaluating several parameters in a few tests selected by a robust statistical method.
Materials and methods
The Taguchi table L36 (211 × 312) was used to determine the 72 beams needed to test the 7 parameters chosen: energy, MLC, depth, jaw field size in X, Y1 and Y2 directions and wedge. Measurements were conducted in water using a CC04 (IBA) on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a C-serie clinac (Varian). Dose was computed using the AAA algorithm (Eclipse, version 11). The same raw data was used for all accelerators during the algorithm configuration.
Results
The mean difference between computed and measured doses was 0.1 ±± 0.5% for all tested beams and all linacs with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all linacs. No studied parameter led to statistically significant deviation between computed and measured doses.
Conclusion
Experimental design is a robust statistical method to validate an algorithm. Only 2 h of measurements were needed to evaluate 7 parameters. Furthermore, the commissioned accelerators were found dosimetrically equivalent even though the linac characteristics differ
Intermittent diazepam and continuous phenobarbital to treat recurrence of febrile seizures: a systematic review with meta-analysis
Paracetamol serum concentrations in preterm infants treated with paracetamol intravenously: a case series
<p>Abstract</p> <p>Introduction</p> <p>Until now, studies on paracetamol given intravenously have mainly been performed with the pro-drug propacetamol or with paracetamol in preterm babies above 32 weeks of gestation. Studies in these babies indicate that intravenous paracetamol is tolerated well, however studies on the efficacy of intravenous paracetamol are lacking. There are no pharmacokinetic data on the administration of multiple doses of paracetamol in preterm babies with a gestational age below 32 weeks.</p> <p>Case presentation</p> <p>We present a case series of nine Caucasian preterm babies, six boys and three girls, with a mean gestational age of 28.6 weeks (range 25.9 to 31.6 weeks). Case one, a girl with a gestational age of 25 weeks and six days, presented with necrotizing enterocolitis. In the second case, a female baby with a gestational age of 26 weeks and two days presented with hematoma. In case three, a female baby with a gestation of 26 weeks and one day developed intraventricular hemorrhage. In case four, a male baby with a gestational age of 31 weeks and four days presented with pain after vacuum delivery. Case five, a female baby born after a gestation of 29 weeks and six days presented with hematoma. In case six, a male baby with a gestation of 30 weeks and six days presented with hematoma. In case seven, a male baby, born with a gestational age of 30 weeks and six days, presented with caput succedaneum and hematoma. In case eight, a male baby, born after a gestation of 28 weeks and four days, developed abdominal distention. Case nine, a female baby, born with a gestational age of 27 weeks and three days presented with hematoma. These babies were treated with intravenous paracetamol 15 mg/kg every six hours. Serum concentrations and aspartate transaminase were determined after prolonged administration. Pain scores were assessed using the Premature Infant Pain Profile.</p> <p>Conclusion</p> <p>Paracetamol serum concentrations ranged from 8 to 64 mg/L after eight to 12 doses of intravenous paracetamol. Adequate analgesia was obtained in seven babies. During paracetamol therapy the median serum level of aspartate transaminase was 20 U/L (range 12 to 186 U/L). This case series indicates that prolonged intravenous administration of paracetamol in preterm babies with a gestational age of less than 32 weeks is tolerated well in the first days after birth. However, in the absence of proper pharmacokinetic data in this age group we cannot advocate the use of paracetamol intravenously.</p
Role of Mitofusin 2 in the Renal Stress Response
The role of mitofusin 2 (MFN2), a key regulator of mitochondrial morphology and function in the renal stress response is unknown. To assess its role, the MFN2 floxed gene was conditionally deleted in the kidney of mice (MFN2 cKO) by Pax2 promoter driven Cre expression (Pax2Cre). MFN2 cKO caused severe mitochondrial fragmentation in renal epithelial cells that are critical for normal kidney tubular function. However, despite a small (20%) decrease in nephron number, newborn cKO pups had organ or tubular function that did not differ from littermate Cre-negative pups. MFN2 deficiency in proximal tubule epithelial cells in primary culture induced mitochondrial fragmentation but did not significantly alter ATP turnover, maximal mitochondrial oxidative reserve capacity, or the low level of oxygen consumption during cyanide exposure. MFN2 deficiency also did not increase apoptosis of tubule epithelial cells under non-stress conditions. In contrast, metabolic stress caused by ATP depletion exacerbated mitochondrial outer membrane injury and increased apoptosis by 80% in MFN2 deficient vs. control cells. Despite similar stress-induced Bax 6A7 epitope exposure in MFN2 deficient and control cells, MFN2 deficiency significantly increased mitochondrial Bax accumulation and was associated with greater release of both apoptosis inducing factor and cytochrome c. In conclusion, MFN2 deficiency in the kidney causes mitochondrial fragmentation but does not affect kidney or tubular function during development or under non-stress conditions. However, MFN2 deficiency exacerbates renal epithelial cell injury by promoting Bax-mediated mitochondrial outer membrane injury and apoptosis
- …
