275 research outputs found
Medicosocial outcome after admission in post-intensive care unit at PRM St-Hélier, Rennes
IntroductionPost-Intensive Care Units (PICU) are PRM structures aiming to start the appropriated rehabilitative care as early as possible even though persistent complex medical issues.ObjectiveTo assess medicosocial outcomes of patients away from their admission in PICU.MethodsA retrospective descriptive study that included 81 consecutive patients (mean age 51 years) admitted from 2008 to 2012 in the PICU of Pôle St-Helier Rennes based on called semi-structured interviews between March 2014 and March 2015. Exhaustive data (only 4 lost, 5%) by the patient himself and/or a member of family on autonomy, place of life, structures since the release and reintegration, of patients for 85% of them brain damaged.ResultsThere is 29% (21/77) of death (post-exit life: 1,6 years±1.18). Eighty percent live at home (46/56) of which only 5 without family environment, 10% (5/56) in medicosocial structures (foster or nursing homes…), 10% in hospital (hospital at home, persistent vegetative units…). Fourteen percent (8/56) are completely autonomous and work, all with adaptations. Twenty-three percent (13/56) had a significant dependence for activities of daily life and instrumental ones. Forty percent (22/56) have no hobby. Use of different downstream structures, long-term readaptative monitoring, legal and families’ feelings were also analyzed.Discussion and ConclusionMedical and social outcome of patients in the aftermath of a stay in PICU is disparate, depending on the pathology involved, but also the pre-social situation that seems to be the main predictor of returning home. Most patients have regained a relatively large autonomy for the daily life activities but are embarrassed to complex instrumental activities impeding social inclusion. These results are consistent with those of the literature on head trauma patients but no other study has focused for the moment on the specific population of patients admitted to the PICU. We see the value of such early rehabilitative care units with a real impact on the subsequent independence and opportunities back home
Mise en place de la Maîtrise Statistique des Procédés pour les contrôles pré-traitement par imagerie portale pour la technique VMAT
National audienc
Design of experiments in medical physics: Application to the AAA beam model validation
Purpose
The purpose of this study is to evaluate the usefulness of the design of experiments in the analysis of multiparametric problems related to the quality assurance in radiotherapy. The main motivation is to use this statistical method to optimize the quality assurance processes in the validation of beam models.
Method
Considering the Varian Eclipse system, eight parameters with several levels were selected: energy, MLC, depth, X, Y1 and Y2 jaw dimensions, wedge and wedge jaw. A Taguchi table was used to define 72 validation tests. Measurements were conducted in water using a CC04 on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a 2300IX accelerator matched by the vendor. Dose was computed using the AAA algorithm. The same raw data was used for all accelerators during the beam modelling.
Results
The mean difference between computed and measured doses was 0.1 ± 0.5% for all beams and all accelerators with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all accelerators. The energy was found to be an influencing parameter but the deviations observed were smaller than 1% and not considered clinically significant.
Conclusion
Designs of experiment can help define the optimal measurement set to validate a beam model. The proposed method can be used to identify the prognostic factors of dose accuracy. The beam models were validated for the 4 accelerators which were found dosimetrically equivalent even though the accelerator characteristics differ
Unusual cause of severe toxic methemoglobinemia in an infant: a case report
Toxic methemoglobinemia is an uncommon blood disorder induced by exposure to certain oxidizing agents and drugs. In severe cases, this condition may rapidly lead to major cardiopulmonary compromise and constitutes an emergency requiring prompt recognition and early management. We report an unusual case of severe toxic methemoglobinemia following wide cutaneous application of a pomade containing benzocaine, resorcin, and oxyquinoline (Nestosyl®) in an infant
Correlations of structural, magnetic, and dielectric properties of undoped and doped CaCu3Ti4O12
The present work reports synthesis, as well as a detailed and careful
characterization of structural, magnetic, and dielectric properties of
differently tempered undoped and doped CaCu3Ti4O12 (CCTO) ceramics. For this
purpose, neutron and x-ray powder diffraction, SQUID measurements, and
dielectric spectroscopy have been performed. Mn-, Fe-, and Ni-doped CCTO
ceramics were investigated in great detail to document the influence of
low-level doping with 3d metals on the antiferromagnetic structure and
dielectric properties. In the light of possible magnetoelectric coupling in
these doped ceramics, the dielectric measurements were also carried out in
external magnetic fields up to 7 T, showing a minor but significant dependence
of the dielectric constant on the applied magnetic field. Undoped CCTO is
well-known for its colossal dielectric constant in a broad frequency and
temperature range. With the present extended characterization of doped as well
as undoped CCTO, we want to address the question why doping with only 1% Mn or
0.5% Fe decreases the room-temperature dielectric constant of CCTO by a factor
of ~100 with a concomitant reduction of the conductivity, whereas 0.5% Ni
doping changes the dielectric properties only slightly. In addition,
diffraction experiments and magnetic investigations were undertaken to check
for possible correlations of the magnitude of the colossal dielectric constants
with structural details or with magnetic properties like the magnetic ordering,
the Curie-Weiss temperatures, or the paramagnetic moment. It is revealed, that
while the magnetic ordering temperature and the effective moment of all
investigated CCTO ceramics are rather similar, there is a dramatic influence of
doping and tempering time on the Curie-Weiss constant.Comment: 10 pages, 11 figure
A new robust statistical method for treatment planning systems validation using experimental designs
Introduction
Dose computation verification is an important part of acceptance testing. The IAEA Tecdoc 1540 and 1583 suggest comparing computed dose to measurements for several beam configurations. However, this process is time-consuming and results out of tolerance are often left unexplained.
Purpose
To validate a treatment planning system using experimental designs which allow evaluating several parameters in a few tests selected by a robust statistical method.
Materials and methods
The Taguchi table L36 (211 × 312) was used to determine the 72 beams needed to test the 7 parameters chosen: energy, MLC, depth, jaw field size in X, Y1 and Y2 directions and wedge. Measurements were conducted in water using a CC04 (IBA) on a TrueBeam STx, a TrueBeam Tx, a Trilogy and a C-serie clinac (Varian). Dose was computed using the AAA algorithm (Eclipse, version 11). The same raw data was used for all accelerators during the algorithm configuration.
Results
The mean difference between computed and measured doses was 0.1 ±± 0.5% for all tested beams and all linacs with a maximum difference of 2.4% (under the 3% tolerance level). For all beams, the measured doses were within 0.6% for all linacs. No studied parameter led to statistically significant deviation between computed and measured doses.
Conclusion
Experimental design is a robust statistical method to validate an algorithm. Only 2Â h of measurements were needed to evaluate 7 parameters. Furthermore, the commissioned accelerators were found dosimetrically equivalent even though the linac characteristics differ
GATE : a simulation toolkit for PET and SPECT
Monte Carlo simulation is an essential tool in emission tomography that can
assist in the design of new medical imaging devices, the optimization of
acquisition protocols, and the development or assessment of image
reconstruction algorithms and correction techniques. GATE, the Geant4
Application for Tomographic Emission, encapsulates the Geant4 libraries to
achieve a modular, versatile, scripted simulation toolkit adapted to the field
of nuclear medicine. In particular, GATE allows the description of
time-dependent phenomena such as source or detector movement, and source decay
kinetics. This feature makes it possible to simulate time curves under
realistic acquisition conditions and to test dynamic reconstruction algorithms.
A public release of GATE licensed under the GNU Lesser General Public License
can be downloaded at the address http://www-lphe.epfl.ch/GATE/
- …