913 research outputs found

    First Year PIDDP Report on gamma-ray and x-ray spectroscopy: X-ray remote sensing and in situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in situ spectroscopy for planetary exploration missions

    Get PDF
    Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. In addition, it is important to characterize a detector system at uneven portions of its life cycle, for example after exposure to different amounts of radiation. A calibration and response characterization facility has been constructed at Schlumberger-Doll Research for all types of gamma- and x-ray detectors that may be used for planetary measurement. This facility is currently being tested. Initial use is expected for the MARS 94 detectors. The facility will then also be available for calibrating other detectors as well as arrays of detectors such as the NEAR detector with its central Nal(TI) crystal surrounded with a large BGO crystal. Cadmium telluride detectors are investigated for applications in space explorations. These detectors show an energy resolution of 5 keV for the 122 keV 57Co line. Earlier reported polarization effects are not observed. The detectors can be used at temperatures up to 100 C, although with reduced energy resolution. The thickness of standard detectors is limited to 2 mm. These detectors become fully efficient at bias voltages above 200 V. Initial results for a 1 cm thick detector show that the quality of the material is inferior to the thinner standard detectors and hole trapping affects the pulse height. A detailed characterization of the detector is in progress. Prototypes of photomultipliers based on a Channel Electron Multiplier (CEM) are being built to study their performance. Such photomultipliers promise better timing characteristics and a higher dynamic range while being more compact and of lower in weight

    Discovery of macrocyclic inhibitors of apurinic/apyrimidinic endonuclease 1

    Get PDF
    Apurinic/apyrimidinic endonuclease 1 (APE1) is an essential base excision repair enzyme that is upregulated in a number of cancers, contributes to resistance of tumors treated with DNA-alkylating or -oxidizing agents, and has recently been identified as an important therapeutic target. In this work, we identified hot spots for binding of small organic molecules experimentally in high resolution crystal structures of APE1 and computationally through the use of FTMAP analysis (http://ftmap.bu.edu/). Guided by these hot spots, a library of drug-like macrocycles was docked and then screened for inhibition of APE1 endonuclease activity. In an iterative process, hot-spot-guided docking, characterization of inhibition of APE1 endonuclease, and cytotoxicity of cancer cells were used to design next generation macrocycles. To assess target selectivity in cells, selected macrocycles were analyzed for modulation of DNA damage. Taken together, our studies suggest that macrocycles represent a promising class of compounds for inhibition of APE1 in cancer cells.This work was supported by grants from the National Institutes of Health (Grant R01CA205166 to M.R.K. and M.M.G. and Grant R01CA167291 to M.R.K.) and by the Earl and Betty Herr Professor in Pediatric Oncology Research, Jeff Gordon Children's Foundation, and the Riley Children's Foundation (M.R.K.). Work at the BU-CMD (J.A.P., L.E.B., R.T.) is supported by the National Institutes of Health, Grant R24 GM111625. D.B. and S.V. were supported by the National Institutes of Health, Grant R35 GM118078. (R35 GM118078 - National Institutes of Health; R01CA205166 - National Institutes of Health; R01CA167291 - National Institutes of Health; R24 GM111625 - National Institutes of Health; Earl and Betty Herr Professor in Pediatric Oncology Research; Jeff Gordon Children's Foundation; Riley Children's Foundation)Accepted manuscriptSupporting documentatio

    Electronic Structure of Lanthanum Hydrides with Switchable Optical Properties

    Full text link
    Recent dramatic changes in the optical properties of LaH_{2+x} and YH_{2+x} films discovered by Huiberts et al. suggest their electronic structure is described best by a local model. Electron correlation is important in H^- -centers and in explaining the transparent insulating behavior of LaH_3. The metal-insulator transition at x0.8x\sim 0.8 takes place in a band of highly localized states centered on the HH-vacancies in the LaH_3 structure.Comment: plain tex, 3 figure

    A semi-field evaluation in Thailand of the use of human landing catches (HLC) versus human-baited double net trap (HDN) for assessing the impact of a volatile pyrethroid spatial repellent and pyrethroid-treated clothing on; Anopheles minimus; landing

    Get PDF
    BACKGROUND: The mosquito landing rate measured by human landing catches (HLC) is the conventional endpoint used to evaluate the impact of vector control interventions on human-vector exposure. Non-exposure based alternatives to the HLC are desirable to minimize the risk of accidental mosquito bites. One such alternative is the human-baited double net trap (HDN), but the estimated personal protection of interventions using the HDN has not been compared to the efficacy estimated using HLC. This semi-field study in Sai Yok District, Kanchanaburi Province, Thailand, evaluates the performance of the HLC and the HDN for estimating the effect on Anopheles minimus landing rates of two intervention types characterized by contrasting modes of action, a volatile pyrethroid spatial repellent (VSPR) and insecticide-treated clothing (ITC). METHODS: Two experiments to evaluate the protective efficacy of (1) a VPSR and (2) ITC, were performed. A block randomized cross-over design over 32 nights was carried out with both the HLC or HDN. Eight replicates per combination of collection method and intervention or control arm were conducted. For each replicate, 100 An. minimus were released and were collected for 6 h. The odds ratio (OR) of the released An. minimus mosquitoes landing in the intervention compared to the control arm was estimated using logistic regression, including collection method, treatment, and experimental day as fixed effects. RESULTS: For the VPSR, the protective efficacy was similar for the two methods: 99.3%, 95% CI (99.5-99.0) when measured by HLC, and 100% (100, Inf) when measured by HDN where no mosquitoes were caught (interaction test p = 0.99). For the ITC, the protective efficacy was 70% (60-77%) measured by HLC but there was no evidence of protection when measured by HDN [4% increase (15-27%)] (interaction test p < 0.001). CONCLUSIONS: Interactions between mosquitoes, bite prevention tools and the sampling method may impact the estimated intervention protective efficacy. Consequently, the sampling method must be considered when evaluating these interventions. The HDN is a valid alternative trapping method (relative to the HLC) for evaluating the impact of bite prevention methods that affect mosquito behaviour at a distance (e.g. VPSR), but not for interventions that operate through tarsal contact (e.g., ITC)

    Yang-Lee zeros for a nonequilibrium phase transition

    Full text link
    Equilibrium systems which exhibit a phase transition can be studied by investigating the complex zeros of the partition function. This method, pioneered by Yang and Lee, has been widely used in equilibrium statistical physics. We show that an analogous treatment is possible for a nonequilibrium phase transition into an absorbing state. By investigating the complex zeros of the survival probability of directed percolation processes we demonstrate that the zeros provide information about universal properties. Moreover we identify certain non-trivial points where the survival probability for bond percolation can be computed exactly.Comment: LaTeX, IOP-style, 13 pages, 10 eps figure

    Beable trajectories for revealing quantum control mechanisms

    Get PDF
    The dynamics induced while controlling quantum systems by optimally shaped laser pulses have often been difficult to understand in detail. A method is presented for quantifying the importance of specific sequences of quantum transitions involved in the control process. The method is based on a ``beable'' formulation of quantum mechanics due to John Bell that rigorously maps the quantum evolution onto an ensemble of stochastic trajectories over a classical state space. Detailed mechanism identification is illustrated with a model 7-level system. A general procedure is presented to extract mechanism information directly from closed-loop control experiments. Application to simulated experimental data for the model system proves robust with up to 25% noise.Comment: Latex, 20 pages, 13 figure

    Teratogenic risk and contraceptive counselling in psychiatric practice: analysis of anticonvulsant therapy

    Get PDF
    &lt;p&gt;Background: Anticonvulsants have been used to manage psychiatric conditions for over 50 years. It is recognised that some, particularly valproate, carbamazepine and lamotrigine, are human teratogens, while others including topiramate require further investigation. We aimed to appraise the documentation of this risk by psychiatrists and review discussion around contraceptive issues.&lt;/p&gt; &lt;p&gt;Methods: A retrospective review of prescribing patterns of four anticonvulsants (valproate, carbamazepine, lamotrigine and topiramate) in women of child bearing age was undertaken. Documented evidence of discussion surrounding teratogenicity and contraceptive issues was sought.&lt;/p&gt; &lt;p&gt;Results: Valproate was most commonly prescribed (n=67). Evidence of teratogenic risk counselling at medication initiation was sub-optimal – 40% of individuals prescribed carbamazepine and 22% of valproate. Documentation surrounding contraceptive issues was also low- 17% of individuals prescribed carbamazepine and 13% of valproate.&lt;/p&gt; &lt;p&gt;Conclusion: We found both low rates of teratogenic risk counselling and low rates of contraception advice in our cohort. Given the high rates of unplanned pregnancies combined with the relatively high risk of major congenital malformations, it is essential that a detailed appraisal of the risks and benefits associated with anticonvulsant medication occurs and is documented within patients’ psychiatric notes.&lt;/p&gt

    Thermal regimes of HTS cylinders operating in devices for fault current limitation

    Full text link
    We reveal obstacles related to the application of HTS cylinders in current limiting devices based on the superconducting - normal state transition. It is shown that, at the critical current density achieved presently in bulk materials, and especially in BSCCO-2212, the required thickness of the cylinder wall in a full-scale inductive device achieves several centimeters. A simple mathematical model of the operation of an inductive fault current limiter (FCL) is used to show that such cylinders cannot be cooled in admissible time after a fault clearing and, hence, the inductive FCLs and current-limiting transformers employing BSCCO cylinders do not return to the normal operation in the time required. For the recovery even with a non-current pause in the circuit, the cylinders are needed with the critical current density by an order higher than the existed ones.Comment: 15 pages, 5 figure
    corecore