2,488 research outputs found

    Optimization of lighting projects including photopic and circadian criteria: A simplified action protocol

    Get PDF
    Lighting projects that consider parameters related to circadian light remain rare. Using controlled lighting on both photopic and melanopic levels, this study aims to simplify the design of circadian lighting projects based on traditional photometric parameters and calculations. A real classroom is used to illustrate the behavior of horizontal (visual stimuli) and vertical (circadian contribution) illuminances under different design parameters, such as the varied reflectance of walls, ceiling, and floor; varied spatial distribution curves, including the number and position of luminaires; and across the spectral power distribution of a variety of LEDs. In this work, we seek to clarify and simplify to the greatest possible extent the meaning and scope of various lighting standards while establishing simple protocols. Our results will enable designers to carry out optimized lighting projects from both the photometric and circadian perspectives

    Reference normal values and design of a vision screening for 4 to 5 years old preschoolers

    Get PDF
    A vision screening program for preschool children of 4-5 years old was designed and analyzed. Information of the prevalence of ocular conditions among preschool children was obtained. The vision health of a group of 127 children was evaluated by a comprehensive examination in their own school. If a child failed one or more screening tests, he was referred to the ophthalmologist. Of the children screened in this study, 61% passed distance visual acuity and retinoscopy tests, 17% were referred to the ophthalmologist and 22% will be annually monitoring. Values of monocular/binocular acuity worse than 0.5/0.6 are too poor for 4 years old children, whereas these limits increase up to 0.6/0.8 for 5 years old children. In conclusion, the prevalence of undetected vision problems in preschool children has been clearly demonstrated. Vision screening programs in schools are highly recommended. Nevertheless, coordination among professionals conducting screening, school personnel and parents are needed to reach high levels of success. The results of this study validate an easy and fast battery of tests. The vision screening has been highly reliable because reference normal values have been defined by analyzing statistically the results of these tests. Se diseñó y analizó un screening visual en preescolares de 4-5 años de edad. Se obtuvo información de la prevalencia de las condiciones oculares entre estos preescolares. Se evaluó la salud visual de un grupo de 127 niños con un examen completo en su propia escuela. Si el niño fallaba uno o más test era referido al oftalmólogo. De los niños revisados en el estudio, el 61% superó los test de agudeza visual y retinoscopía, al 17% se le refirió al oftalmólogo y el 22% será controlado anualmente. Valores de agudeza monocular/binocular peores de 0.5/0.6 son demasiado bajos para niños de 4 años de edad, mientras que estos límites se incrementan a 0.6/0.8 para niños de 5 años. En conclusión, la prevalencia de problemas de visión sin detectar en niños preescolares ha sido claramente demostrada. Sin embargo, es necesaria la coordinación entre profesionales que realicen el screening, personal del colegio y padres para alcanzar niveles altos de éxito. Los resultados de este estudio validan una batería rápida de test. El screening visual ha sido altamente fiable porque los valores normales de referencia han sido definidos analizando estadísticamente los resultados de estos tests

    Evaluación de 80 implantes, sometidos a carga inmediata en desdentados inferiores tras un seguimiento de dos años

    Get PDF
    Objetivo: Analizar el comportamiento tanto clínico como radiológico de ochentas implantes con una nueva superficie tratada mediante una disolución de ácido sulfúrico y fluorhídrico con posterior tratamiento térmico, que han sido sometidos a carga inmediata en pacientes rehabilitados con sobredentaduras inferiores. Diseño del artículo: Estudio observacional, prospectivo en 20 pacientes rehabilitados con sobredentaduras inferiores, soportadas sobre cuatro implantes de 13 milímetros de longitud. Todos los pacientes fueron planificados e incluídos tras el consentimiento, anamnesis, exploración clínica y estudio radiográfico y mediante montaje clínico previo de la prótesis inferior. Resultados: Durante los dos años de seguimiento, se ha obervado que el acúmulo de placa y cálculo no ha sido importante, oscilando los índices (Silness y Löe) entre 0 y 1. El sondaje periodontal, ha sido favorable no encontrando pacientes que superasen 2 milímetros. Los controles radiográficos mostraron a lo largo del seguimiento ausencia de fracaso implantológico. Las pérdidas óseas cervicales, durante el primer año, no existieron en un alto porcentaje (65%), mientras que en un 10% se produjo la reabsorción de la mitad cervical y en el 35% restante sobre las ¾ partes cervicales. El comportamiento durante el segundo año fue compatible a los patrones estándares, observándose pérdidas que oscilaron entre 0,5 y 1,5 milímetros. Conclusiones: La rehabilitación mediante sobredentaduras inferiores, debiera contemplarse como una indicación prioritaria, planteándose la sustitución de los tratamientos implantológicos con períodos de reposo convencionales y/o precoces.Aim: An analysis is made of the clinical and radiological behavior of 80 implants with a new surface subjected to etching with a sulfuric and hydrofluoric acid solution followed by thermal treatment, and subjected to immediate loading in patients with lower overdentures. Study design: A prospective observational study was made of 20 patients with lower overdentures supported by four implants measuring 13 mm in length. All patients were included after the obtainment of informed consent, anamnesis, clinical examination and radiological study, with prior clinical elaboration of the lower dentures. Results: Over two years of follow-up, no important plaque or tartar accumulation was observed (with Silness and Löe indexes of 0-1). Periodontal probing proved favorable, with no pocket depths of over 2 mm in any case. The radiological controls showed no implant failures during follow-up. No cervical bone loss was recorded in the first year in a large proportion of cases (65%), while reabsorption of the cervical half was observed in 10%, and of three-quarters of the cervical portion in the remaining 35%. Performance in the second year was compatible with the standard references ' with losses of between 0.5-1.5 mm. Conclusions: Rehabilitation with lower overdentures should be regarded as a priority indication, and implantological treatment substitution by conventional and/or early resting periods should be considered

    Improving the Wear and Corrosion Resistance of Maraging Part Obtained by Cold Gas Spray Additive Manufacturing

    Get PDF
    The use of the cold gas spray (CGS) process as a metal additive manufacturing (MAM) technique for metallic part production has been deeply studied recently, mainly due to its advantages over other MAM techniques. CGS MAM is a high-productivity technique with a very low level of particle oxidation, microstructural changes, phase transformations, or deleterious residual thermal stresses in the part. The use of CGS MAM to produce maraging parts represents a gain for the industry by saving machining time and preventing raw material waste. Its wear resistance and corrosion behavior were evaluated in this work and were compared with cermet coatings deposited by high-velocity oxy-fuel (HVOF) on the CGS MAM maraging. This work presents the innovative and effective combination of different thermal spraying processes and materials to obtain MAM maraging parts with higher wear resistance, evaluating abrasion, sliding, and water erosion wear type

    Surgical ciliated cyst of the maxilla. Clinical case

    Get PDF
    Surgical ciliated cyst is uncommon in Western countries but frequently reported in Asian populations as a delayed complication of surgery, with inclusion in the bone of nasal or sinus mucosa. Isolated cases have also been reported in the mandible after orthognathic surgery. We report a case in the maxillary region three years after radical sinus surgery for chronic sinusitis. Intraoral examination revealed a small painless tumefaction with no color change in the surrounding tissues. Computed tomography demonstrated a well-defined intraosseous lesion lateral to the maxillary sinus. The lesion was completely excised, when histology demonstrated a pseudostratified ciliated epithelial lining. Differential diagnosis from other lesions such as an odontogenic keratocyst or inflammatory cyst were also made. This case report,uncommon in Western countries, of a surgical ciliated cyst illustrates the need for a meticulous surgical technique, proper management of complications, and routine, long-term follow-up of patients undergoing any type of sinus surgery

    The influence of the powder characteristics on 316L stainless steel coatings sprayed by cold gas spray

    Get PDF
    Thermally sprayed 316L stainless steel coatings are commonly used on metallic structures due to their corrosion and wear resistance when compared to carbon steel. Cold Gas Spray (CGS) is a convenient thermal spray process to deposit 316L coatings, producing thick and very dense coatings, with almost no deleterious changes on the feedstock properties to the coating condition. The powder characteristics have influence on the microstructure of the coating, such as porosity and oxide contents, which alter its corrosion and wear behavior. CGS is an efficient technique to reduce the problems associated with material melting commonly found in other conventional thermal spray methods. In this work, different 316L powders, produced by different manufacturers, were deposited by CGS, applying the same equipment and parameters, with the objective to evaluate the relation between the powders' characteristics and coating properties. Their microstructure, adherence, hardness, as well as the performance on corrosion and wear testing were evaluated. The water atomized powders presented in general better results than gas atomized powders
    corecore