161 research outputs found

    ENERGETICS APPROACH TO FATIGUE BEHAVIOR OF WOODEN JOINT USING DOUBLE-SIDED ADHESIVE TAPE

    Get PDF
    The authors have previously studied the possibility of the use of industrial double-sided adhesive tape as a method for jointing wooden panel to wooden framework. The mechanical performance of joints formed by such methods is comparable to that of nailed joint under static load conditions. However, the mechanical performance of such joints has not been evaluated under cyclic load conditions. This study was conducted to investigate this aspect of their performance. Double-shear specimens were prepared by bonding wooden panel to wooden framework using two types of adhesive tape with different substrates. Specimens were also prepared with wooden dowels to strengthen their jointing performance. The joint specimens were subjected to cyclic shear loading testing. The results of the tests were analyzed from an energetics perspective, and the shear deformability of the specimens at failure was estimated. The test results indicate that both the specimens formed using adhesive tape and those formed using wooden dowels had fatigue properties comparable to nailed joint specimens. A tendency for the shear deformability caused by cyclic loading to increase with the stress level was observed. It was possible to estimate the shear deformability by evaluating the energy absorption capacity of the joints from an energetics standpoint

    A New 100-GHz Band Front-End System with a Waveguide-Type Dual-Polarization Sideband-Separating SIS Receiver for the NRO 45-m Radio Telescope

    Full text link
    We developed a waveguide-type dual-polarization sideband-separating SIS receiver system of the 100-GHz band for the 45-m radio telescope at the Nobeyama Radio Observatory, Japan. This receiver is composed of an ortho-mode transducer and two sideband-separating SIS mixers, which are both based on the waveguide technique. The receiver has four intermediate frequency bands of 4.0--8.0 GHz. Over the radio frequency range of 80--120 GHz, the single-sideband receiver noise temperatures are 50--100 K and the image rejection ratios are greater than 10 dB. We developed new matching optics for the telescope beam as well as new IF chains for the four IF signals. The new receiver system was installed in the telescope, and we successfully observed the 12CO, 13CO and C18O emission lines simultaneously toward the Sagittarius B2 region to confirm the performance of the receiver system. The SSB noise temperature of the system, including the atmosphere, became approximately half of that of the previous receiver system. The Image Rejection Ratios (IRRs) of the two 2SB mixers were calculated from the 12CO and HCO+ spectra from the W51 giant molecular cloud, resulting in > 20 dB for one polarization and > 12 dB for the other polarization.Comment: 10 pages, 13 figures, Accepted for publication in PASJ, version with high resolution figures is available via http://www.nro.nao.ac.jp/library/report/list.htm

    Use of Cervical Ultrasonography in Globus Sensation Investigation: A Retrospective Cohort Study

    Get PDF
    Background: A globus sensation is one of the most common complaints in otolaryngological practice. Patients with no associated abnormalities detected during the usual examinations performed in ENT clinics, are being diagnosed with globus sensation. Cervical ultrasonography is usually not performed in ENT clinics; however, it is useful in screening diseases of the subcutaneous tissue/organs, whose detection is not possible with the routine ENT examinations. The purpose of our study was to elucidate whether cervical ultrasound examination identifies abnormalities in patients with globus sensation. Methods: A single-centre retrospective cohort study. Cervical ultrasonographic examinations were performed on patients with globus sensation at the Department of Otolaryngology, Head and Neck Surgery of Tottori university hospital, a tertiary care centre, from January 2013 to September 2017. The subjects were 74 patients who complained of globus sensation with no abnormality in general otolaryngological examination including laryngoscopy. Results: Ultrasonography detected structural abnormalities in 60.8% of the patients with globus sensation: thyroid disorders in 41 patients, including: 35 patients with thyroid nodules, 4 patients with Hashimoto’s disease, 1 patient with Grave’s disease, and 1 patient with subacute thyroiditis; Sjögren syndrome in 2 patients; and cervical lipoma in 1 patient. Furthermore, 2 patients with thyroid disorders had concomitant esophageal cancer. Conclusion: Cervical ultrasonography identified thyroid disorders in patients with globus sensation, despite the normal ENT status. Therefore, it would be appropriate to adopt cervical ultrasonography as a routine examination at ENT clinics for patients with globus sensation

    Performance of a liquid scintillator containing a zirconium β-keto ester complex developed for the ZICOS experiment

    Get PDF
    A liquid scintillator containing a zirconium β-keto ester complex has been developed for the ZIrconium Complex in Organic Scintillator (ZICOS) neutrinoless double beta decay experiment. We are aiming to develop a detector which has a good energy resolution (4% at 2.5 MeV), a large light yield (60% that of BC505) and a low background rate (0.1 counts/tonne・year) with several tonnes of 96Zr isotope, so we have investigated the zirconium β-keto ester complexes tetrakis (isopropyl acetoacetato) zirconium and tetrakis (ethyl acetoacetato) zirconium, which have high solubility (over 10 wt.%) in anisole. We measured the performance of liquid scintillators containing these zirconium β-keto ester complexes and obtained 40% of the light yield of BC505 and energy resolution of 4.1% at 2.5 MeV assuming 40% photo coverage of the photomultiplier in the ZICOS detector. Thus we almost achieved our initial goal. Preliminary investigations indicate that tetrakis (diethyl malonato) zirconium will give us no quenching of the light yield and an energy resolution of 2.9% at 2.5 MeV. This will be a suitable complex for the ZICOS experiment, if it has a large solubility

    Wind- and Operation-Induced Vibration Measurements of the Main Reflector of the Nobeyama 45 m Radio Telescope

    Full text link
    As deformations of the main reflector of a radio telescope directly affect the observations, the evaluation of the deformation is extremely important. Dynamic characteristics of the main reflector of the Nobeyama 45 m radio telescope, Japan, are measured under two conditions: The first is when the pointing observation is in operation, and the second is when the reflector is stationary and is subjected to wind loads when the observation is out of operation. Dynamic characteristics of the main reflector are measured using piezoelectric accelerometers. When the telescope is in operation, a vibration mode with one nodal line horizontally or vertically on the reflector is induced, depending on whether the reflector is moving in the azimuthal or elevational planes, whereas under windy conditions, vibration modes that have two to four nodal lines are simultaneously induced. The predominant mode is dependent on the direction of wind loads.Comment: Accepted for publication in Journal of Vibration Engineering & Technologie

    Discrimination of Cherenkov light in Liquid Scintillator for Neutrinoless Double Beta Decay Experiment

    Get PDF
     A liquid scintillator containing a tetrakis(isopropyl acetoacetato)zirconium has been developed for ZICOS experiment. We will use 180 tons of liquid scintillator containing 75 kg of 96Zr in the inner balloon(45 kg in fiducial volume)surrounding 64 % photo coverage of 20 inch photomultiplier. In order to reach the sensitivity ≥1027 years, we have to reduce 95 % of 208Tl decay backgrounds at least. Using Monte Carlo simulation, we could demonstrate new method using the hit pattern of PMT which received Cherenkov light, and could reduce 93 % of 208Tl background with 78 % efficiency for 0νββ signal. For the discrimination of Cherenkov light, we measured the timing pulse shape of Zr loaded liquid scintillator using FADC digitizer, and we found an inconsistent pulse shape at the rise timing with the template of scintillation. Also the event with an inconsistent pulse shape seems to have a directionality

    Direct measurement of spectral shape of Cherenkov light using cosmic muons

    Get PDF
    The spectral pulse shape of Cherenkov lights was directly measured by using cosmic muons. The observed decay times for early and late timing were 5.0 and 5.2ns, respectively. They were actually shorter than the time of scintillation lights which were also measured as 9.3ns and 9.2ns, respectively. However we could not see the difference of the rise time between scintillation and Cherenkov lights. This was due to the slow response of our DAQ equipment, photomultiplier and FADC digitize

    Precise pulse shape measurement of Cherenkov light using sub-MeV electrons from Sr-90/Y-90 beta source

    Get PDF
    The precise spectral pulse shape from Cherenkov lights was directly measured by using sub-MeV electrons from 90Sr/90Y beta source. The observed shape was clearly different from the shape of scintillation light. The pulse rise and fall (decay) time for Cherenkov light were 0.8 ns and 2.5 ns, respectively. They were actually shorter than those times of scintillation light which were also measured by 1.6 ns and 6.5 ns, respectively. This clear Thisclearclear difference of rise time will be used for the pulse shape discrimination in order to select PMTs which receive Cherenkov lights, and the topological information due to Cherenkov light will be used for the reduction of backgrounds from 208Tl beta decay which should be major backgrounds observed around Q-value (3.35MeV)of 96Zr neutrinoless double beta decay
    corecore