31,932 research outputs found
Application of the scalar and vector potentials to the aerodynamics of jets
The applicability of a method based on the Stokes potentials (vector and scalar potentials) to computations associated with the aerodynamics of jets was examined. The aerodynamic field near the nozzle could be represented and that the influence of a nonuniform velocity profile at the nozzle exit plane could be determined. Also computations were made for an axisymmetric jet exhausting into a quiescient atmosphere. The velocity at the axis of the jet, and the location of the half-velocity points along the jet yield accurate aerodynamic field computations. Inconsistencies among the different theoretical characterizations of jet flowfields are shown
Comparison of data on Mutation Frequencies of Mice Caused by Radiation - Low Dose Model -
We propose LD(Low Dose) model, the extension of LDM model which was proposed
in the previous paper [Y. Manabe et al.: J. Phys. Soc. Jpn. 81 (2012) 104004]
to estimate biological damage caused by irradiation. LD model takes account of
all the considerable effects including cell death effect as well as
proliferation, apoptosis, repair. As a typical example of estimation, we apply
LD model to the experiment of mutation frequency on the responses induced by
the exposure to low levels of ionizing radiation. The most famous and extensive
experiments are those summarized by Russell and Kelly [Russell, W. L. & Kelly,
E. M: Proc. Natl Acad. Sci. USA 79 (1982) 539-541], which are known as
'Mega-mouse project'. This provides us with important information of the
frequencies of transmitted specific-locus mutations induced in mouse
spermatogonia stem-cells. It is found that the numerical results of the
mutation frequency of mice are in reasonable agreement with the experimental
data: the LD model reproduces the total dose and dose rate dependence of data
reasonably. In order to see such dose-rate dependence more explicitly, we
introduce the dose-rate effectiveness factor (DREF). This represents a sort of
preventable effects such as repair, apoptosis and death of broken cells, which
are to be competitive with proliferation effect of broken cells induced by
irradiation.Comment: subimitting to J. Phys. Soc. Jpn, 32 pages, 8 figure
Three-dimensional modeling of lightning-induced electromagnetic pulses on Venus, Jupiter and Saturn
While lightning activity in Venus is still controversial, its existence in
Jupiter and Saturn was first detected by the Voyager missions and later on
confirmed by Cassini and New Horizons optical recordings in the case of
Jupiter, and recently by Cassini on Saturn in 2009. Based on a recently
developed 3D model we investigate the influence of lightning-emitted
electromagnetic pulses (EMP) on the upper atmosphere of Venus, Saturn and
Jupiter. We explore how different lightning properties such as total energy
released and orientation (vertical, horizontal, oblique) can produce
mesospheric transient optical emissions of different shapes, sizes and
intensities. Moreover, we show that the relatively strong background magnetic
field of Saturn can enhance the lightning-induced quasi-electrostatic and
inductive electric field components above 1000 km of altitude producing
stronger transient optical emissions that could be detected from orbital
probes
Fiber optic control system integration
A total fiber optic, integrated propulsion/flight control system concept for advanced fighter aircraft is presented. Fiber optic technology pertaining to this system is identified and evaluated for application readiness. A fiber optic sensor vendor survey was completed, and the results are reported. The advantages of centralized/direct architecture are reviewed, and the concept of the protocol branch is explained. Preliminary protocol branch selections are made based on the F-18/F404 application. Concepts for new optical tools are described. Development plans for the optical technology and the described system are included
Experience with a vectorized general circulation weather model on Star-100
A version of an atmospheric general circulation model was vectorized to run on a CDC STAR 100. The numerical model was coded and run in two different vector languages, CDC and LRLTRAN. A factor of 10 speed improvement over an IBM 360/95 was realized. Efficient use of the STAR machine required some redesigning of algorithms and logic. This precludes the application of vectorizing compilers on the original scalar code to achieve the same results. Vector languages permit a more natural and efficient formulation for such numerical codes
Symptomatic adrenal insufficiency during inhaled corticosteroid treatment
Symptomatic adrenal insufficiency, presenting
as hypoglycaemia or poor weight
gain, may occur on withdrawal of corticosteroid
treatment but has not previously
been reported during inhaled corticosteroid
treatment. This case series illustrates
the occurence of clinically
significant adrenal insufficiency in asthmatic
children while patients were on
inhaled corticosteroid treatment and the
unexpected modes of presentation. General
practitioners and paediatricians need
to be aware that this unusual but acute
serious complication may occur in patients
treated
Nurse telephone triage for same day appointments in general practice: multiple interrupted time series trial of effect on workload and costs
OBJECTIVE: To compare the workloads of general practitioners and nurses and costs of patient care for nurse telephone triage and standard management of requests for same day appointments in routine primary care. DESIGN: Multiple interrupted time series using sequential introduction of experimental triage system in different sites with repeated measures taken one week in every month for 12 months. SETTING: Three primary care sites in York. Participants: 4685 patients: 1233 in standard management, 3452 in the triage system. All patients requesting same day appointments during study weeks were included in the trial. MAIN OUTCOME MEASURES: Type of consultation (telephone, appointment, or visit), time taken for consultation, presenting complaints, use of services during the month after same day contact, and costs of drugs and same day, follow up, and emergency care. RESULTS: The triage system reduced appointments with general practitioner by 29-44%. Compared with standard management, the triage system had a relative risk (95% confidence interval) of 0.85 (0.72 to 1.00) for home visits, 2.41 (2.08 to 2.80) for telephone care, and 3.79 (3.21 to 4.48) for nurse care. Mean overall time in the triage system was 1.70 minutes longer, but mean general practitioner time was reduced by 2.45 minutes. Routine appointments and nursing time increased, as did out of hours and accident and emergency attendance. Costs did not differ significantly between standard management and triage: mean difference £1.48 more per patient for triage (95% confidence interval -0.19 to 3.15). CONCLUSIONS: Triage reduced the number of same day appointments with general practitioners but resulted in busier routine surgeries, increased nursing time, and a small but significant increase in out of hours and accident and emergency attendance. Consequently, triage does not reduce overall costs per patient for managing same day appointments
- …