1,332 research outputs found

    Planck pre-launch status: High Frequency Instrument polarization calibration

    Get PDF
    The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization (ΔP/T_(cmb) ~ 4 × 10^(-6) for P either Q or U and T_(cmb) ≃ 2.7 K) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the cosmic microwave background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the E-mode spectrum (up to l ~ 1500) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of the instrument as well as the combination of different detectors. We use this method to propagate errors through to the CMB angular power spectra in the particular case of Planck-HFI, and to derive constraints on polarization parameters. We show that in order to limit the systematic error to 10% of the cosmic variance of the E-mode power spectrum, uncertainties in gain, polarization efficiency and detector orientation must be below 0.15%, 0.3% and 1° respectively. Pre-launch ground measurements reported in this paper already fulfill these requirements

    Total knee arthroplasty in valgus knee

    Get PDF
    SummaryTotal knee arthroplasty (TKA) in valgus knee has the reputation of being more difficult than in well aligned or varus knee, and there is no management consensus. Results on a continuous series of 100 TKAs on valgus knee were compared to the literature data, to define surgical strategy adapted to the various types of valgus knee

    Cementless RM Pressfit® Cup. A clinical and radiological study of 91 cases with at least four years follow-up

    Get PDF
    AbstractCementless metal-back acetabular cups have good long-term results, but some problems have appeared due to the shell's stiffness, modularity and required bearing surfaces. The RM Pressfit® Cup is a single-piece polyethylene cementless acetabular cup that is covered by a thin layer of titanium. This allows for bone integration without limitations related to the stiffness of a metal-back shell. There is very little published information about this new, innovative implant design. The purpose of this study was to evaluate the clinical and radiological results from a continuous series of 91 cups (85 patients) with a follow-up of at least 4years. No patients were lost to follow-up. The Harris Hip Score (HHS) was used to assess the clinical outcome. To assess the radiological outcomes, digital X-rays were used to evaluate the cup position and integration; wear was measured using Livermore's technique. The clinical results were excellent: the mean HHS was 94 and 82% of cases had good or excellent scores. Three of the cups had to be revised because of dislocation brought on by incorrect positioning. X-rays revealed that three implants had shifted during the first 6weeks, but had stabilized afterwards. Bone integration on X-rays was satisfactory in all cases with no signs of osteolysis. The configuration of the bone trabeculae showed that loads between the implant and peri-acetabular cancellous bone were evenly distributed. The wear of the polyethylene cup-ceramic head bearing was 0.07mm/year. The results of this series are consistent with recent published studies with the RM Pressfit® Cup.Level of evidenceIV

    Nutritional status of Lusitano broodmares on extensive feeding systems: body condition, live weight and metabolic indicators

    Get PDF
    Articles in International JournalsThe present research aimed to evaluate the effects of foaling season and feeding management in extensive systems on the nutritional status of Lusitano broodmares throughout the gestation/lactation cycle, by assessment of body condition (BC), body weight (BW), and some blood metabolic indicators. Four groups of Lusitano broodmares (A, B, C, D) were monitored during four years, in a total of 119 gestation/lactation cycles. All mares were kept on pasture, and A and B mares were daily supplemented. Monthly, mares were weighed and BC evaluated. Suckling foals from these mares were also monitored for BW and withers height. Glucose, non-esterified fatty acids, urea and albumin concentrations were determined in blood. BW changes were influenced by reproductive stage and foaling season (P<0.001), reflecting also pasture availability. Changes on BC were observed (P<0.05), although with small amplitudes within each group. Higher scores were reached at the end of spring, decreasing 0.25 point until late summer. Early foaling had also a marked effect, hindering the recovery of BC along the cycle. Glucose values decreased from late gestation to early lactation (P<0.05) and lower levels were recorded during the summer months. Uremia was mainly influenced by the reproductive stage (P<0.05). Under nutrition was not detected. Foals born in February-March had higher average daily gain than those born in April-May (P<0.05), probably reflecting differences in milk production of the mares. BC and BW changes and, particularly, blood indicators showed an overall balanced nutritional status, reflecting an adaptation to feed availability and climate.Portuguese Foundation for Science and Technolog

    Common peroneal nerve palsy complicating knee dislocation and bicruciate ligaments tears

    Get PDF
    SummaryIntroductionThe occurrence rate of common peroneal nerve (CPN) palsy associated with knee dislocation or bicruciate ligament injury ranges from 10 to 40%. The present study sought first to describe the anatomic lesions encountered and their associated prognoses and second to recommend adequate treatment strategy based on a prospective multicenter observational series of knee ligament trauma cases.Material and methodsTwelve out of 67 knees treated for dislocation or bicruciate lesion presented associated CPN palsy: two females, 10 males; mean age, 32 years. Four sports injuries, three traffic accidents and five other etiologies led to seven complete dislocations and five bicruciate ruptures. Four cases involved associated popliteal artery laceration ischemia; one of the dislocations was open. Paralysis was total in eight cases and partial in four. There were two complete ruptures, three contusions with CPN in continuity stretch lesions and three macroscopically normal aspects.ResultsAt a minimum 1 year's follow-up, regardless of the initial surgical technique performed, recovery was complete in six cases, partial (in terms of motor function) in one and absent in five. Without specific CPN surgery, spontaneous recovery was partial in one case, complete in two and absent in none. Following simple emergency or secondary neurolysis, remission was total in four cases and absent in one. Three nerve grafts were all associated with non-recovery.DiscussionThe present results agree with literature findings. Palsy rates varied with trauma circumstances and departmental recruitment. Neurologic impairment was commensurate to ligamentary damages. The anatomic status of the CPN, subjected to violent traction by dislocation, was the most significant prognostic factor for neurologic recovery. In about 25% of dislocations, contusion-elongation over several centimeters was associated with as poor a prognosis as total rupture. CPN neurolysis is recommended when early clinical and EMG recovery fails to progress and/or in case of lateral ligamentary reconstruction. Possible peripheral nerve impairment needs to be included in the overall functional assessment of treatment for severe ligaments injuries and knee dislocation.Level of evidenceLevel IV, prospective study

    Status of the LHCb magnet system

    Get PDF
    The LHCb experiment focuses on the precision measurement of CP violation and rare decays in the B-meson system. It plans to operate with an average luminosity of 2×10322\times 10^{32}~cm−2^{-2}s −1~^{-1}, which should be obtained from the beginning of the LHC operation. The LHCb detector exploits the forward region of the pp collisions at the LHC collider. It requires a single-arm spectrometer for the separation and momentum measurement of the charged particles with a large dipole magnet of a free aperture of ±300\pm 300~mrad horizontally and ±250\pm 250~mrad vertically. The magnet is designed for a total integrated field of 4~Tm. The pole gap is 2.2 to 3.5~m vertically (the direction of the field) and 2.6 to 4.2~m horizontally. The overall length of the magnet (in beam direction) is 5~m and its total weight about 1500~t. The power dissipation in the aluminium coils will be 4.2~MW. The magnet yoke is constructed from low carbon steel plates of 100~mm thickness. The maximum weight of one plate does not exceed 25~t. The coils are wound from large hollow aluminium conductor of 50 mm×50 mm50~{\rm mm}\times 50~{\rm mm} cross-section with a central cooling channel of 25~mm diameter for the pressurized demineralized water. Each of the two coils is composed of 15~monolayer pancakes of 15~turns per pancake. To reach good field quality the coils are bent by 45∘^\circ towards the gap along the horizontal aperture of ±300\pm 300~mrad and the pole pieces have large shims. The underlying magnet design, its present status and milestones will be reviewed

    Community detection by consensus genetic-based algorithm for directed networks

    Get PDF
    Finding communities in networks is a commonly used form of network analysis. There is a myriad of community detection algorithms in the literature to perform this task. In spite of that, the number of community detection algorithms in directed networks is much lower than in undirected networks. However, evaluation measures to estimate the quality of communities in undirected networks nowadays have its adaptation to directed networks as, for example, the well-known modularity measure. This paper introduces a genetic-based consensus clustering to detect communities in directed networks with the directed modularity as the fitness function. Consensus strategies involve combining computational models to improve the quality of solutions generated by a single model. The reason behind the development of a consensus strategy relies on the fact that recent studies indicate that the modularity may fail in detecting expected clusterings. Computational experiments with artificial LFR networks show that the proposed method was very competitive in comparison to existing strategies in the literature. (C) 2016 The Authors. Published by Elsevier B.V.Instituto de Ciência e Tecnologia, Universidade Federal de São Paulo (UNIFESP) Av. Cesare M. G. Lattes, 1201, Eugênio de Mello, São José dos Campos-SP, CEP: 12247-014, BrasilInstituto de Ciência e Tecnologia, Universidade Federal de São Paulo (UNIFESP) Av. Cesare M. G. Lattes, 1201, Eugênio de Mello, São José dos Campos-SP, CEP: 12247-014, BrasilWeb of Scienc
    • …
    corecore