1,918 research outputs found

    A laser diode based system for calibration of fast time-of-flight detectors

    Full text link
    A system based on commercially available items, such as a laser diode, emitting in the visible range ∼400\sim 400 nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of multi-channels time-of-flight (TOF) detectors with photomultipliers' (PMTs') readout. As available laser diode sources have unfortunately limited peak power, the main experimental problem is the tight light power budget of such a system. In addition, while the technology for fused fiber splitters is common in the Telecom wavelength range (λ∼850,1300−1500\lambda \sim 850, 1300-1500 nm), it is not easily available in the visible one. Therefore, extensive laboratory tests had to be done on purpose, to qualify the used optical components, and a full scale timing calibration prototype was built. Obtained results show that with such a system, a calibration resolution (σ\sigma) in the range 20-30 ps may be within reach. Therefore, fast multi-channels TOF detectors, with timing resolutions in the range 50-100 ps, may be easily calibrated in time. Results on tested optical components may be of interest also for time calibration of different light detection systems based on PMTs, as the ones used for detection of the vacuum ultraviolet scintillation light emitted by ionizing particles in large LAr TPCs.Comment: submitted to JINS

    The Timing Counter of the MEG experiment: calibration and performance

    Full text link
    The MEG detector is designed to test Lepton Flavor Violation in the μ+→e+γ\mu^+\rightarrow e^+\gamma decay down to a Branching Ratio of a few 10−1310^{-13}. The decay topology consists in the coincident emission of a monochromatic photon in direction opposite to a monochromatic positron. A precise measurement of the relative time te+γt_{e^+\gamma} is crucial to suppress the background. The Timing Counter (TC) is designed to precisely measure the time of arrival of the e+e^+ and to provide information to the trigger system. It consists of two sectors up and down stream the decay target, each consisting of two layers. The outer one made of scintillating bars and the inner one of scintillating fibers. Their design criteria and performances are described.Comment: Presented at the 12th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD10) 7 - 10 June 2010, Siena. Accepted by Nuclear Physics B (Proceedings Supplements) (2011)tal

    Discovery of a radio relic in the low mass, merging galaxy cluster PLCK G200.9-28.2

    Get PDF
    Radio relics at the peripheries of galaxy clusters are tracers of the elusive cluster merger shocks. We report the discovery of a single radio relic in the galaxy cluster PLCK G200.9-28.2 (z=0.22z=0.22, M500=2.7±0.2×1014M⊙M_{500} = 2.7\pm0.2 \times 10^{14} M_{\odot}) using the Giant Metrewave Radio Telescope at 235 and 610 MHz and the Karl G. Jansky Very Large Array at 1500 MHz. The relic has a size of ∼1×0.28\sim 1 \times 0.28 Mpc, an arc-like morphology and is located at 0.9 Mpc from the X-ray brightness peak in the cluster. The integrated spectral index of the relic is 1.21±0.151.21\pm0.15. The spectral index map between 235 and 610 MHz shows steepening from the outer to the inner edge of the relic in line with the expectation from a cluster merger shock. Under the assumption of diffusive shock acceleration, the radio spectral index implies a Mach number of 3.3±1.83.3\pm1.8 for the shock. The analysis of archival XMM Newton data shows that PLCK G200.9-28.2 consists of a northern brighter sub-cluster, and a southern sub-cluster in a state of merger. This cluster has the lowest mass among the clusters hosting single radio relics. The position of the Planck Sunyaev Ze'ldovich effect in this cluster is offset by 700 kpc from the X-ray peak in the direction of the radio relic, suggests a physical origin for the offset. Such large offsets in low mass clusters can be a useful tool to select disturbed clusters and to study the state of merger.Comment: 10 pages, 7 figures, 4 tables. Accepted for publication in MNRA

    Behaviour in Magnetic Fields of Fast Conventional and Fine-Mesh Photomultipliers

    Full text link
    The performance of both conventional and fine-mesh Hamamatsu photomultipliers has been measured inside moderate magnetic fields. This has allowed the test of effective shielding solutions for photomultipliers, to be used in time-of-flight detectors based on scintillation counters. Both signal amplitude reduction or deterioration of the timing properties inside magnetic fields have been investigated

    Structural and Dynamic Characterization of Li-Ionic Liquid Electrolyte Solutions for Application in Li-Ion Batteries: A Molecular Dynamics Approach

    Get PDF
    Pyrrolidinium-based (Pyr) ionic liquids (ILs) have been proposed as electrolyte components in lithium-ion batteries (LiBs), mainly due to their higher electrochemical stability and wider electrochemical window. Since they are not naturally electroactive, in order to allow their use in LiBs, it is necessary to mix the ionic liquids with lithium salts (Li). Li-PF6, Li-BF4, and Li-TFSI are among the lithium salts more frequently used in LiBs, and each anion, namely PF6 (hexafluorophosphate), BF4 (tetrafluoroborate), and TFSI (bis(trifluoromethanesulfonyl)azanide), has its own solvation characteristics and interaction profile with the pyrrolidinium ions. The size of Pyr cations, the anion size and symmetry, and cation-anion combinations influence the Li-ion solvation properties. In this work, we used molecular dynamics calculations to achieve a comprehensive view of the role of each cation-anion combination and of different fractions of lithium in the solutions to assess their relative advantage for Li-ion battery applications, by comparing the solvation and structural properties of the systems. This is the most-comprehensive work so far to consider pyrrolidinium-based ILs with different anions and different amounts of Li: from it, we can systematically determine the role of each constituent and its concentration on the structural and dynamic properties of the electrolyte solutions

    Time of flight detectors with SiPMT array readout

    Get PDF
    none6noTime-of-flight detectors, based on scintillation counters, may use conventional photomultipliers for the readout. Problems arise in presence of external magnetic fields. SiPMT arrays are insensitive to magnetic fields and may be a suitable option to replace photomultipliers. Timing performances for several types of SiPMT arrays have been studied and results are presented.Bonesini, M; Bertoni, R.; de Bari, A.; Nardò, R.; Prata, M.; Rossella, M.Bonesini, M; Bertoni, R.; DE BARI, Antonio; Nardo', Roberto; Prata, M.; Rossella, M
    • …
    corecore