1,059 research outputs found

    Interval training normalizes cCardiomyocyte function, diastolic Ca<sup>2+</sup> control, and SR Ca<sup>2+</sup> release synchronicity in a mouse model of diabetic cardiomyopathy

    Get PDF
    In the present study we explored the mechanisms behind excitation-contraction (EC)-coupling defects in cardiomyocytes from mice with type-2 diabetes (db/db), and determined whether 13-weeks of aerobic interval training could restore cardiomyocyte Ca2+ cycling and EC-coupling. Reduced contractility in cardiomyocytes isolated from sedentary db/db was associated with increased diastolic sarcoplasmic reticulum (SR)-Ca2+ leak, reduced synchrony of Ca2+ release, reduced transverse (T)-tubule density, and lower peak systolic and diastolic Ca2+ and caffeine-induced Ca2+ release. Additionally, the rate of SR Ca2+ ATPase (SERCA2a)-mediated Ca2+ uptake during diastole was reduced, whereas a faster recovery from caffeine-induced Ca2+ release indicated increased Na+/Ca2+- exchanger (NCX) activity. The increased SR-Ca2+ leak was attributed to increased Ca2+-calmodulindependent protein kinase (CaMKII&#948;) phosphorylation, supported by the normalization of SR-Ca2+ leak upon inhibition of CaMKII&#948; (AIP). Exercise training restored contractile function associated with restored SR Ca2+ release synchronicity, T-tubule density, twitch Ca2+ amplitude, SERCA2a and NCX activities, and SR-Ca2+ leak. The latter was associated with reduced phosphorylation of cytosolic CaMKII&#948;. Despite normal contractile function and Ca2+ handling after the training period, phospholamban was hyperphosphorylated at Serine-16. Protein kinase A (PKA) inhibition (H-89) in cardiomyocytes from the exercised db/db group abolished the differences in SR-Ca2+ load when compared with the sedentary db/db mice. EC-coupling changes were observed without changes in serum insulin or glucose levels, suggesting that the exercise training-induced effects are not via normalization of the diabetic condition. These data demonstrate that aerobic interval training almost completely restored the contractile function of the diabetic cardiomyocyte to levels close to sedentary wild type (WT)

    Leptospirose em bovinos: revisão

    Get PDF
    A leptospirose bovina é uma doença cosmopolita, reconhecida no Brasil desde o século XIX. Muitos prejuízos econômicos são associados à enfermidade, principalmente em decorrência das complicações reprodutivas e sistêmicas que acarreta aos animais. Atualmente existem 13 espécies patogênicas, sendo os humanos suscetíveis à maioria delas. O diagnóstico pode ser obtido através da identificação do agente ou detecção de anticorpos. A imunohistoquímica, imunoperoxidade indireta, o exame bacteriológico e reação da cadeia em polimerase são bastante utilizadas, porém o teste de soroaglutinação microscópica é considerado padrão. Existem medidas de prevenção e controle empregadas aos rebanhos, entretanto as mais recomendadas são a vacinação dos animais e desratização

    Psychological aspects of pre-symptomatic testing for Machado–Joseph disease and familial amyloid polyneuropathy type I

    Get PDF
    Machado–Joseph disease [MJD, also spinocerebellar ataxia type 3 (SCA3)] and familial amyloid polyneuropathy type I (FAP-I or ATTR V30M) are neurodegenerative disorders, inherited in an autosomal dominant fashion, which have a high prevalence in Portugal, probably due to a founder effect. MJD and FAP-I are late-onset diseases, with symptoms emerging usually during adulthood. CGPP, which is the national reference centre for these disorders, has a genetic lab that offers diagnostic, pre-symptomatic and prenatal testing and an outpatient clinic to counsel and follow relatives at risk for hereditary ataxias, FAP- I and Huntington disease (HD). The present work is a review of our 10- year experience with psychological counselling of individuals at risk for MJD and FAP-I. Persons at risk for FAP-I may show a better response to pre-symptomatic testing than those who are at risk for MJD and HD because of the availability of liver transplantation, which may improve their health and life expectancy. Psychological well-being and specific distress of MJD and FAP-I test applicants, before undergoing genetic testing (baseline level) and 3 to 6 months after disclosure of test results, have shown a low level of change, both in identified carriers and non-carriers. A major goal of psychological characterization of at-risk individuals for MJD and FAP-I is to determine the factors that influence the uptake of genetic testing

    Microclimate in coffee plantation grown under grevillea trees shading.

    Get PDF
    Microclima de café arborizado com grevílea. Medições de radiação solar global, velocidade do vento, temperatura e umidade relativa do ar, foram realizadas em um cafezal (Coffea arabica L.) cv. Icatu Vermelho IAC 4045, cultivado a pleno sol e arborizado com grevílea (Grevillea robusta), no município de Mococa ? SP (21º 28? S, 47º 01? W, altitude 665 m) entre janeiro e dezembro de 2005, com o objetivo de apresentar os efeitos do cultivo arborizado no microclima. Os resultados obtidos mostraram que houve atenuação média dos valores de radiação solar global, em cultivo de café arborizado, em 26%, com variação mensal de 24 a 30%. Pela descontinuidade da cobertura das árvores de grevílea, foi verificada diferença de transmissão da radiação solar em diferentes pontos do sistema arborizado. Foi verificada ainda redução média de 35% nas médias quinquidiais da velocidade do vento no cultivo arborizado em relação ao cultivo a pleno sol. O cultivo arborizado promoveu redução na temperatura máxima do ar e no déficit de saturação de vapor no período diurno, sendo essas reduções mais evidentes no ponto amostral próximo à árvore de grevílea

    Modelagem analítica de geração solar térmica de eletricidade, com concentradores parabólicos de foco linear

    Get PDF
    Foi desenvolvido um modelo analítico de um sistema solar térmico de geração de eletricidade, com concentradores parabólicos de foco linear. O modelo permite simular, realizar análises de sensibilidade e otimizar o desempenho do sistema. A troca de calor entre o absorvedor do coletor solar e o fluido térmico, ao longo do tubo absorvedor, é estudada levando em consideração a não linearidade das perdas do coletor, bem como sua dependência da temperatura local do absorvedor. O acoplamento entre o coletor e o ciclo termodinâmico está materializado por três trocadores de calor, onde se processa a evolução do fluido térmico e da água em vapor superaquecido. O fluido termodinâmico (vapor-agua) descreve um ciclo de Carnot, no qual os processos irreversíveis estão representados pelas trocas externas de calor. A solução analítica desenvolvida reúne simplicidade e precisão, sendo uma alternativa atrativa às soluções semi-empíricas utilizadas atualmente. A semelhança dos resultados obtidos a partir do modelo apresentado neste trabalho com os valores experimentais de literatura é altamente satisfatória.An analytic model of a solar thermal electric generation system with parabolic trough collectors was developed. The model allows to simulate and to optimize the system operation as well as to develop a sensitivity analysis. It is studied the heat exchange between the solar collector absorber and the thermal fluid along the absorber tube, taking into consideration the non-linearity of the heat losses and its dependence on the local temperature. The coupling between the collector and the thermodynamic cycle is materialized by three heat exchangers, where it is processed the thermal fluid and water/steam evolution. The analytic solutions obtained associate simplicity and precision, being an attractive alternative to semi-empiric solutions frequently used in the technical literature. Good agreement is shown by the comparison of the results of this model with semi-empirical solutions and experimental values published in the literature.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Mechanisms underlying cytotoxicity induced by engineered nanomaterials: a review of in vitro studies

    Get PDF
    Engineered nanomaterials are emerging functional materials with technologically interesting properties and a wide range of promising applications, such as drug delivery devices, medical imaging and diagnostics, and various other industrial products. However, concerns have been expressed about the risks of such materials and whether they can cause adverse effects. Studies of the potential hazards of nanomaterials have been widely performed using cell models and a range of in vitro approaches. In the present review, we provide a comprehensive and critical literature overview on current in vitro toxicity test methods that have been applied to determine the mechanisms underlying the cytotoxic effects induced by the nanostructures. The small size, surface charge, hydrophobicity and high adsorption capacity of nanomaterial allow for specific interactions within cell membrane and subcellular organelles, which in turn could lead to cytotoxicity through a range of different mechanisms. Finally, aggregating the given information on the relationships of nanomaterial cytotoxic responses with an understanding of its structure and physicochemical properties may promote the design of biologically safe nanostructures

    Modelagem analítica de geração solar térmica de eletricidade, com concentradores parabólicos de foco linear

    Get PDF
    Foi desenvolvido um modelo analítico de um sistema solar térmico de geração de eletricidade, com concentradores parabólicos de foco linear. O modelo permite simular, realizar análises de sensibilidade e otimizar o desempenho do sistema. A troca de calor entre o absorvedor do coletor solar e o fluido térmico, ao longo do tubo absorvedor, é estudada levando em consideração a não linearidade das perdas do coletor, bem como sua dependência da temperatura local do absorvedor. O acoplamento entre o coletor e o ciclo termodinâmico está materializado por três trocadores de calor, onde se processa a evolução do fluido térmico e da água em vapor superaquecido. O fluido termodinâmico (vapor-agua) descreve um ciclo de Carnot, no qual os processos irreversíveis estão representados pelas trocas externas de calor. A solução analítica desenvolvida reúne simplicidade e precisão, sendo uma alternativa atrativa às soluções semi-empíricas utilizadas atualmente. A semelhança dos resultados obtidos a partir do modelo apresentado neste trabalho com os valores experimentais de literatura é altamente satisfatória.An analytic model of a solar thermal electric generation system with parabolic trough collectors was developed. The model allows to simulate and to optimize the system operation as well as to develop a sensitivity analysis. It is studied the heat exchange between the solar collector absorber and the thermal fluid along the absorber tube, taking into consideration the non-linearity of the heat losses and its dependence on the local temperature. The coupling between the collector and the thermodynamic cycle is materialized by three heat exchangers, where it is processed the thermal fluid and water/steam evolution. The analytic solutions obtained associate simplicity and precision, being an attractive alternative to semi-empiric solutions frequently used in the technical literature. Good agreement is shown by the comparison of the results of this model with semi-empirical solutions and experimental values published in the literature.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Modelagem analítica de geração solar térmica de eletricidade, com concentradores parabólicos de foco linear

    Get PDF
    Foi desenvolvido um modelo analítico de um sistema solar térmico de geração de eletricidade, com concentradores parabólicos de foco linear. O modelo permite simular, realizar análises de sensibilidade e otimizar o desempenho do sistema. A troca de calor entre o absorvedor do coletor solar e o fluido térmico, ao longo do tubo absorvedor, é estudada levando em consideração a não linearidade das perdas do coletor, bem como sua dependência da temperatura local do absorvedor. O acoplamento entre o coletor e o ciclo termodinâmico está materializado por três trocadores de calor, onde se processa a evolução do fluido térmico e da água em vapor superaquecido. O fluido termodinâmico (vapor-agua) descreve um ciclo de Carnot, no qual os processos irreversíveis estão representados pelas trocas externas de calor. A solução analítica desenvolvida reúne simplicidade e precisão, sendo uma alternativa atrativa às soluções semi-empíricas utilizadas atualmente. A semelhança dos resultados obtidos a partir do modelo apresentado neste trabalho com os valores experimentais de literatura é altamente satisfatória.An analytic model of a solar thermal electric generation system with parabolic trough collectors was developed. The model allows to simulate and to optimize the system operation as well as to develop a sensitivity analysis. It is studied the heat exchange between the solar collector absorber and the thermal fluid along the absorber tube, taking into consideration the non-linearity of the heat losses and its dependence on the local temperature. The coupling between the collector and the thermodynamic cycle is materialized by three heat exchangers, where it is processed the thermal fluid and water/steam evolution. The analytic solutions obtained associate simplicity and precision, being an attractive alternative to semi-empiric solutions frequently used in the technical literature. Good agreement is shown by the comparison of the results of this model with semi-empirical solutions and experimental values published in the literature.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES
    corecore