456 research outputs found

    The idea of moral panic – ten dimensions of dispute

    Get PDF
    This paper explores the open and contested concept of moral panic over its 40-year history, exploring the contributions made by the concept’s key originators, as well as contemporary researchers. While most moral panic researchers are critical, humanist, interpretivist, interventionist and qualitative, this paper highlights ten areas of productive dispute within and around the meaning of moral panic theory’s ‘common sense’. Such diversity of interpretation creates multiple possibilities for convergent and divergent theorization and research within a supposedly singular conceptual framework. This lack of closure and consequent diversity of political standpoints, intellectual perspectives and fields of empirical focus, rather than representing the weakness of the concept of moral panic, reflects and contributes to its successful diffusion, escalation and innovation

    PANIC: the new panoramic NIR camera for Calar Alto

    Full text link
    PANIC is a wide-field NIR camera, which is currently under development for the Calar Alto observatory (CAHA) in Spain. It uses a mosaic of four Hawaii-2RG detectors and covers the spectral range from 0.8-2.5 micron(z to K-band). The field-of-view is 30x30 arcmin. This instrument can be used at the 2.2m telescope (0.45arcsec/pixel, 0.5x0.5 degree FOV) and at the 3.5m telescope (0.23arcsec/pixel, 0.25x0.25 degree FOV). The operating temperature is about 77K, achieved by liquid Nitrogen cooling. The cryogenic optics has three flat folding mirrors with diameters up to 282 mm and nine lenses with diameters between 130 mm and 255 mm. A compact filter unit can carry up to 19 filters distributed over four filter wheels. Narrow band (1%) filters can be used. The instrument has a diameter of 1.1 m and it is about 1 m long. The weight limit of 400 kg at the 2.2m telescope requires a light-weight cryostat design. The aluminium vacuum vessel and radiation shield have wall thicknesses of only 6 mm and 3 mm respectively.Comment: This paper has been presented in the SPIE of Astronomical Telescopes and Instrumentation 2008 in Marseille (France

    Heparanase is a prognostic indicator for postoperative survival in pancreatic carcinoma

    Get PDF
    British Journal of Cancer (2002) 87, 689–689. doi:10.1038/sj.bjc.6600504 www.bjcancer.co

    A diffusion-induced transition in the phase separation of binary fluid mixtures subjected to a temperature ramp

    Full text link
    Demixing of binary fluids subjected to slow temperature ramps shows repeated waves of nucleation which arise as a consequence of the competition between generation of supersaturation by the temperature ramp and relaxation of supersaturation by diffusive transport and flow. Here, we use an advection-reaction-diffusion model to study the oscillations in the weak- and strong-diffusion regime. There is a sharp transition between the two regimes, which can only be understood based on the probability distribution function of the composition rather than in terms of the average composition. We argue that this transition might be responsible for some yet unclear features of experiments, like the appearance of secondary oscillations and bimodal droplet size distributions.Comment: 6 pages, 3 color figure

    Characterizing Exoplanets in the Visible and Infrared: A Spectrometer Concept for the EChO Space Mission

    Get PDF
    Transit-spectroscopy of exoplanets is one of the key observational techniques to characterize the extrasolar planet and its atmosphere. The observational challenges of these measurements require dedicated instrumentation and only the space environment allows an undisturbed access to earth-like atmospheric features such as water or carbon-dioxide. Therefore, several exoplanet-specific space missions are currently being studied. One of them is EChO, the Exoplanet Characterization Observatory, which is part of ESA's Cosmic Vision 2015-2025 program, and which is one of four candidates for the M3 launch slot in 2024. In this paper we present the results of our assessment study of the EChO spectrometer, the only science instrument onboard this spacecraft. The instrument is a multi-channel all-reflective dispersive spectrometer, covering the wavelength range from 400 nm to 16 microns simultaneously with a moderately low spectral resolution. We illustrate how the key technical challenge of the EChO mission - the high photometric stability - influences the choice of spectrometer concept and drives fundamentally the instrument design. First performance evaluations underline the fitness of the elaborated design solution for the needs of the EChO mission.Comment: 20 pages, 8 figures, accepted for publication in the Journal of Astronomical Instrumentatio

    GRAVITY: getting to the event horizon of Sgr A*

    Full text link
    We present the second-generation VLTI instrument GRAVITY, which currently is in the preliminary design phase. GRAVITY is specifically designed to observe highly relativistic motions of matter close to the event horizon of Sgr A*, the massive black hole at center of the Milky Way. We have identified the key design features needed to achieve this goal and present the resulting instrument concept. It includes an integrated optics, 4-telescope, dual feed beam combiner operated in a cryogenic vessel; near infrared wavefront sensing adaptive optics; fringe tracking on secondary sources within the field of view of the VLTI and a novel metrology concept. Simulations show that the planned design matches the scientific needs; in particular that 10 microarcsecond astrometry is feasible for a source with a magnitude of K=15 like Sgr A*, given the availability of suitable phase reference sources.Comment: 13 pages, 11 figures, to appear in the conference proceedings of SPIE Astronomical Instrumentation, 23-28 June 2008, Marseille, Franc

    Modification of a conventional photolytic converter for improving aircraft measurements of NO2_{2} via chemiluminescence

    Get PDF
    Nitrogen oxides (NOx_{x}≡NO+NO2_{2}) are centrally involved in the photochemical processes taking place in the Earth\u27s atmosphere. Measurements of NO2_{2}, particularly in remote areas where concentrations are of the order of parts per trillion by volume (pptv), are still a challenge and subject to extensive research. In this study, we present NO2_{2} measurements via photolysis–chemiluminescence during the research aircraft campaign CAFE Africa (Chemistry of the Atmosphere – Field Experiment in Africa) 2018 around Cabo Verde and the results of laboratory experiments to characterize the photolytic converter used. We find the NO2_{2} reservoir species MPN (methyl peroxy nitrate) to produce the only relevant thermal interference in the converter under the operating conditions during CAFE Africa. We identify a memory effect within the conventional photolytic converter (type 1) associated with high NO concentrations and rapidly changing water vapor concentrations, accompanying changes in altitude during aircraft measurements, which is due to the porous structure of the converter material. As a result, NO2_{2} artifacts, which are amplified by low conversion efficiencies, and a varying instrumental background adversely affect the NO2_{2} measurements. We test and characterize an alternative photolytic converter (type 2) made from quartz glass, which improves the reliability of NO2_{2} measurements in laboratory and field studies

    Aptamer-based multiplexed proteomic technology for biomarker discovery

    Get PDF
    Interrogation of the human proteome in a highly multiplexed and efficient manner remains a coveted and challenging goal in biology. We present a new aptamer-based proteomic technology for biomarker discovery capable of simultaneously measuring thousands of proteins from small sample volumes (15 [mu]L of serum or plasma). Our current assay allows us to measure ~800 proteins with very low limits of detection (1 pM average), 7 logs of overall dynamic range, and 5% average coefficient of variation. This technology is enabled by a new generation of aptamers that contain chemically modified nucleotides, which greatly expand the physicochemical diversity of the large randomized nucleic acid libraries from which the aptamers are selected. Proteins in complex matrices such as plasma are measured with a process that transforms a signature of protein concentrations into a corresponding DNA aptamer concentration signature, which is then quantified with a DNA microarray. In essence, our assay takes advantage of the dual nature of aptamers as both folded binding entities with defined shapes and unique sequences recognizable by specific hybridization probes. To demonstrate the utility of our proteomics biomarker discovery technology, we applied it to a clinical study of chronic kidney disease (CKD). We identified two well known CKD biomarkers as well as an additional 58 potential CKD biomarkers. These results demonstrate the potential utility of our technology to discover unique protein signatures characteristic of various disease states. More generally, we describe a versatile and powerful tool that allows large-scale comparison of proteome profiles among discrete populations. This unbiased and highly multiplexed search engine will enable the discovery of novel biomarkers in a manner that is unencumbered by our incomplete knowledge of biology, thereby helping to advance the next generation of evidence-based medicine
    • …
    corecore