419 research outputs found

    Perturbation expansion for 2-D Hubbard model

    Full text link
    We develop an efficient method to calculate the third-order corrections to the self-energy of the hole-doped two-dimensional Hubbard model in space-time representation. Using the Dyson equation we evaluate the renormalized spectral function in various parts of the Brillouin zone and find significant modifications with respect to the second-order theory even for rather small values of the coupling constant U. The spectral function becomes unphysical for UW U \simeq W , where W is the half-width of the conduction band. Close to the Fermi surface and for U<W, the single-particle spectral weight is reduced in a finite energy interval around the Fermi energy. The increase of U opens a gap between the occupied and unoccupied parts of the spectral function.Comment: 17 pages, 11 Postscript figures, Phys. Rev. B, accepte

    Transcatheter Aortic Valve Implantation in Dialysis Patients

    Get PDF
    Background/Aims: Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option for high-risk patients. However, dialysis patients were excluded from all previous studies. The aim of this study is to compare the outcomes of TAVI for dialysis patients with those for patients with chronic kidney disease (CKD) stages 3 and 4 and to compare TAVI with open surgery in dialysis patients. Methods: Part I: comparison of 10 patients on chronic hemodialysis with 116 patients with non-dialysis-dependent CKD undergoing TAVI. Part II: comparison of transcatheter (n = 15) with open surgical (n = 24) aortic valve replacement in dialysis patients. Results: Part I: dialysis patients were significantly younger (72.3 vs. 82.0 years; p < 0.01). Hospital stay was significantly longer in dialysis patients (21.8 vs. 12.1 days; p = 0.01). Overall 30-day mortality was 3.17%, with no deaths among dialysis patients. Six-month survival rates were similar (log-rank p = 0.935). Part II: patient age was comparable (66.5 vs. 69.5 years; p = 0.42). Patients in the surgical group tended to stay longer in hospital than TAVI patients (29.5 vs. 22.5 days; p = 0.35). Conclusion: TAVI is a safe procedure in patients on chronic hemodialysis. Until new data become available, we find no compelling reason to refuse these patients TAVI. Copyright (C) 2012 S. Karger AG, Base

    MIMO-OFDM WDM PON with DM-VCSEL for femtocells application

    Get PDF
    Globalization, rapid technological changes, and growing competition not only facilitate but also make the supply chain more complex and fragile. Any disruption can disturb many organizations and even the whole system. There are many theories and frameworks that present a solution but no study is available that theoretically development framework for supply chain risk management. The focus of this study is to develop a novel framework for identifying the potential risks and assessment of their effects on supply chain performance. Additionally, evaluate the role of supply chain interaction in risk mitigation and performance improvement in Malaysian manufacturing. This is a conceptual paper, systematic as well as content analysis have been done for the literature review. For future study, there is a need to empirically verification of this theoretical framework. The proposed methodology to achieve this framework is; a questionnaire will be developed from a pool and will be validated by exploratory view for risk identification. This questionnaire will be distributed among Malaysian manufacturing and data will be analyzed through Structural Equation Modelling (SEM) for risk assessment and mitigation. The theoretical contribution of this study is support of the theory of swift, even flow as underpinning theory and information processing theory as supportive theory

    Experimental assessment and validation of an oil ferrous wear debris sensors family for wind turbine gearboxes

    Full text link
    [EN] Purpose - The purpose of this study was to perform a complete experimental assessment of a family of oil ferrous wear debris sensor is performed. The family comprised the original sensor and its re-engineered evolution, which is capable of detecting both amount and size of wear debris particles trapped by the sensor and some predefined oil condition properties. Design/methodology/approach ¿ In this work, the first step was to perform a design of experiments for the sensor validation. A specially defined test rig was implemented, and different ferrous wear debris was collected. For each sensor, two different tests were performed. The first test was called a ¿void test¿, where quantified amounts of debris were collided with the sensor without oil. The second one was a dynamic test, where the sensor was installed in the test rig and different amounts of wear debris were added at a constant rate. In addition, specific tests related with oil properties detection were studied. Findings ¿ The results show excellent correlation of the sensor output signal with the amount of wear debris and a satisfactory detection of debris size in all ranges. Also, the dynamic test presented adequate representativeness, and sensors performed well in this scenario. Practical implications ¿ This paper shows the practical implementation of this type of sensor and the usual detection range and rate of detection for different debris size and quantities. Originality/value ¿ This work has a great utility for maintenance managers and equipment designers to fully understand the potential of this type of sensor and its suitability for the application required.Authors would like to thank Iberdrola Generacion S.A. for their support in this project and Universitat Politecnica de Valencia for its support through contract FPI-S2-2015-1065 of Programa de Apoyo para la Investigacion y Desarrollo (PAID). Additionally, the authors would like to especially thank Daniel Veintimilla for their help in this work.Macian Martinez, V.; Tormos, B.; Miró Mezquita, G.; Rodes, I. (2018). Experimental assessment and validation of an oil ferrous wear debris sensors family for wind turbine gearboxes. Sensor Review. 38(1):84-91. https://doi.org/10.1108/SR-04-2017-0065S8491381Chiou, Y.-C., Lee, R.-T., & Tsai, C.-Y. (1998). An on-line Hall-effect device for monitoring wear particle in oils. Wear, 223(1-2), 44-49. doi:10.1016/s0043-1648(98)00289-0Du, L., & Zhe, J. (2011). A high throughput inductive pulse sensor for online oil debris monitoring. Tribology International, 44(2), 175-179. doi:10.1016/j.triboint.2010.10.022Holmberg, K., Adgar, A., Arnaiz, A., Jantunen, E., Mascolo, J., & Mekid, S. (Eds.). (2010). E-maintenance. doi:10.1007/978-1-84996-205-6Sheng, S. (2013), Report on Wind Turbine Subsystem Reliability - A Survey of Various Databases, NREL/PR-5000-59111

    Nitric Oxide-Releasing Aspirin Suppresses NF-κB Signaling in Estrogen Receptor Negative Breast Cancer Cells in Vitro and in Vivo

    Full text link
    Estrogen receptor negative (ER(−)) breast cancer is aggressive, responds poorly to current treatments and has a poor prognosis. The NF-κB signaling pathway is implicated in ER(−) tumorigenesis. Aspirin (ASA) is chemopreventive against ER(+) but not for ER(−) breast cancers. Nitric oxide-releasing aspirin (NO-ASA) is a safer ASA where ASA is linked to an NO-releasing moiety through a spacer. In vitro, we investigated anti-proliferation effects of NO-ASA (para- and meta-isomers) against ER(−) breast cancer cells MDA-MB-231 and SK-BR-23, effects on NF-κB signaling, and reactive oxygen species by standard techniques. In vivo, effects of NO-ASA were evaluated in a mouse xenograft model using MDA-MB-231 cells. p-NO-ASA inhibited the growth of MDA-MB-231 and SK-BR-3 cells at 24 h, the respective IC50s were 13 ± 2 and 17 ± 2 μM; ASA had an IC50 of \u3e3000 μM in both cell lines. The IC50s for m-NO-ASA in MDA-MB-231 and SK-BR-3 were 173 ± 15 and 185 ± 12 μM, respectively, therefore, implying p-NO-ASA as a stronger inhibitor of growth p-NO-ASA reduced cell growth by inhibiting proliferation, inducing apoptosis and causing G0/G1 cell cycle block. Activation of NF-κB was inhibited by both isomers as demonstrated by decreases in NF-κB-DNA binding and luciferase activity at 24 h, However, m-NO-ASA produced transient effects at 3 h such as increased NF-κB-DNA-binding, increased levels of nuclear p50, even though both isomers inhibited IκB degradation. Increase in nuclear p50 by m-NO-ASA was associated with translocation of p50 in to the nucleus as observed by immunoflouresence at 3 h. NO-ASA induced reactive oxygen species (ROS) as evidenced by overall increases in both H2DCFDA (2′,7′-dichlorodihydrofluorescein) and DHE (dihydroethidium)-derived fluorescence. Inhibition of ROS by N-acetyl-cysteine reversed the m-NO-ASA-mediated translocation of p50 in to the nucleus. In xenografts, p-NO-ASA inhibited tumor growth by inhibiting proliferation (PCNA and tumor volume), inducing apoptosis (TUNEL positive cells) and reducing NF-κB expression. Both isomers inhibit cancer cells, inhibit NF-κB pathway and induce ROS, and have potential as anticancer compounds

    Varespladib and cardiovascular events in patients with an acute coronary syndrome: the VISTA-16 randomized clinical trial

    Get PDF
    IMPORTANCE: Secretory phospholipase A2(sPLA2) generates bioactive phospholipid products implicated in atherosclerosis. The sPLA2inhibitor varespladib has favorable effects on lipid and inflammatory markers; however, its effect on cardiovascular outcomes is unknown. OBJECTIVE: To determine the effects of sPLA2inhibition with varespladib on cardiovascular outcomes. DESIGN, SETTING, AND PARTICIPANTS: A double-blind, randomized, multicenter trial at 362 academic and community hospitals in Europe, Australia, New Zealand, India, and North America of 5145 patients randomized within 96 hours of presentation of an acute coronary syndrome (ACS) to either varespladib (n = 2572) or placebo (n = 2573) with enrollment between June 1, 2010, and March 7, 2012 (study termination on March 9, 2012). INTERVENTIONS: Participants were randomized to receive varespladib (500 mg) or placebo daily for 16 weeks, in addition to atorvastatin and other established therapies. MAIN OUTCOMES AND MEASURES: The primary efficacy measurewas a composite of cardiovascular mortality, nonfatal myocardial infarction (MI), nonfatal stroke, or unstable angina with evidence of ischemia requiring hospitalization at 16 weeks. Six-month survival status was also evaluated. RESULTS: At a prespecified interim analysis, including 212 primary end point events, the independent data and safety monitoring board recommended termination of the trial for futility and possible harm. The primary end point occurred in 136 patients (6.1%) treated with varespladib compared with 109 patients (5.1%) treated with placebo (hazard ratio [HR], 1.25; 95%CI, 0.97-1.61; log-rank P = .08). Varespladib was associated with a greater risk of MI (78 [3.4%] vs 47 [2.2%]; HR, 1.66; 95%CI, 1.16-2.39; log-rank P = .005). The composite secondary end point of cardiovascular mortality, MI, and stroke was observed in 107 patients (4.6%) in the varespladib group and 79 patients (3.8%) in the placebo group (HR, 1.36; 95% CI, 1.02-1.82; P = .04). CONCLUSIONS AND RELEVANCE: In patients with recent ACS, varespladib did not reduce the risk of recurrent cardiovascular events and significantly increased the risk of MI. The sPLA2inhibition with varespladib may be harmful and is not a useful strategy to reduce adverse cardiovascular outcomes after ACS. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01130246. Copyright 2014 American Medical Association. All rights reserved

    Constructing a new understanding of the environment under postsocialism

    Get PDF
    This paper introduces a special grouping of papers on the theme of the environment and postsocialism. After the collapse of state socialism in Europe between 1989 and 1991, many immediate approaches to environmental reconstruction assumed that economic liberalisation and democratisation would alleviate problems. Since then, critics have argued that these proposed solutions were themselves problematic, and too closely reflected Western European and North American conceptions of environmental quality and democracy. The result has been a counterreaction focusing on detail and specificity at national levels and below. In this paper, we summarise debates about the environment and postsocialism since the period 1989 - 91. In particular, we examine whether an essentialistic link can be made between state socialism and environmental problems, and how far civil society -- or environmentalism -- may result in an improvement in perceived environmental quality. Finally, we consider the possibility for developing an approach to the environment and postsocialism that lies between crude generalisation and microscale studies

    Effects of the high-density lipoprotein mimetic agent CER-001 on coronary atherosclerosis in patients with acute coronary syndromes: a randomized trial†

    Get PDF
    Aim High-density lipoproteins (HDLs) have several potentially protective vascular effects. Most clinical studies of therapies targeting HDL have failed to show benefits vs. placebo. Objective: To investigate the effects of an HDL-mimetic agent on atherosclerosis by intravascular ultrasonography (IVUS) and quantitative coronary angiography (QCA). Design and setting A prospective, double-blinded, randomized trial was conducted at 51 centres in the USA, the Netherlands, Canada, and France. Intravascular ultrasonography and QCA were performed to assess coronary atherosclerosis at baseline and 3 (2–5) weeks after the last study infusion. Patients Five hundred and seven patients were randomized; 417 and 461 had paired IVUS and QCA measurements, respectively. Intervention Patients were randomized to receive 6 weekly infusions of placebo, 3 mg/kg, 6 mg/kg, or 12 mg/kg CER-001. Main outcome measures The primary efficacy parameter was the nominal change in the total atheroma volume. Nominal changes in per cent atheroma volume on IVUS and coronary scores on QCA were also pre-specified endpoints. Results: The nominal change in the total atheroma volume (adjusted means) was −2.71, −3.13, −1.50, and −3.05 mm3 with placebo, CER-001 3 mg/kg, 6 mg/kg, and 12 mg/kg, respectively (primary analysis of 12 mg/kg vs. placebo: P = 0.81). There was also no difference among groups for the nominal change in per cent atheroma volume (0.02, −0.02, 0.01, and 0.19%; nominal P = 0.53 for 12 mg/kg vs. placebo). Change in the coronary artery score was −0.022, −0.036, −0.022, and −0.015 mm (nominal P = 0.25, 0.99, 0.55), and change in the cumulative coronary stenosis score was −0.51, 2.65, 0.71, and −0.77% (compared with placebo, nominal P = 0.85 for 12 mg/kg and nominal P = 0.01 for 3 mg/kg). The number of patients with major cardiovascular events was 10 (8.3%), 16 (13.3%), 17 (13.7%), and 12 (9.8%) in the four groups. Conclusion: CER-001 infusions did not reduce coronary atherosclerosis on IVUS and QCA when compared with placebo. Whether CER-001 administered in other regimens or to other populations could favourably affect atherosclerosis must await further study. Name of the trial registry: Clinicaltrials.gov; Registry's URL: http://clinicaltrials.gov/ct2/show/NCT01201837?term=cer-001&rank=2; Trial registration number: NCT01201837

    Effects of the high-density lipoprotein mimetic agent CER-001 on coronary atherosclerosis in patients with acute coronary syndromes: a randomized trial†

    Get PDF
    Aim High-density lipoproteins (HDLs) have several potentially protective vascular effects. Most clinical studies of therapies targeting HDL have failed to show benefits vs. placebo. Objective To investigate the effects of an HDL-mimetic agent on atherosclerosis by intravascular ultrasonography (IVUS) and quantitative coronary angiography (QCA). Design and setting A prospective, double-blinded, randomized trial was conducted at 51 centres in the USA, the Netherlands, Canada, and France. Intravascular ultrasonography and QCA were performed to assess coronary atherosclerosis at baseline and 3 (2-5) weeks after the last study infusion. Patients Five hundred and seven patients were randomized; 417 and 461 had paired IVUS and QCA measurements, respectively. Intervention Patients were randomized to receive 6 weekly infusions of placebo, 3 mg/kg, 6 mg/kg, or 12 mg/kg CER-001. Main outcome measures The primary efficacy parameter was the nominal change in the total atheroma volume. Nominal changes in per cent atheroma volume on IVUS and coronary scores on QCA were also pre-specified endpoints. Results The nominal change in the total atheroma volume (adjusted means) was −2.71, −3.13, −1.50, and −3.05 mm3 with placebo, CER-001 3 mg/kg, 6 mg/kg, and 12 mg/kg, respectively (primary analysis of 12 mg/kg vs. placebo: P = 0.81). There was also no difference among groups for the nominal change in per cent atheroma volume (0.02, −0.02, 0.01, and 0.19%; nominal P = 0.53 for 12 mg/kg vs. placebo). Change in the coronary artery score was −0.022, −0.036, −0.022, and −0.015 mm (nominal P = 0.25, 0.99, 0.55), and change in the cumulative coronary stenosis score was −0.51, 2.65, 0.71, and −0.77% (compared with placebo, nominal P = 0.85 for 12 mg/kg and nominal P = 0.01 for 3 mg/kg). The number of patients with major cardiovascular events was 10 (8.3%), 16 (13.3%), 17 (13.7%), and 12 (9.8%) in the four groups. Conclusion CER-001 infusions did not reduce coronary atherosclerosis on IVUS and QCA when compared with placebo. Whether CER-001 administered in other regimens or to other populations could favourably affect atherosclerosis must await further study. Name of the trial registry: Clinicaltrials.gov; Registry's URL: http://clinicaltrials.gov/ct2/show/NCT01201837?term=cer-001&rank=2; Trial registration number: NCT0120183

    Design of Sectoral Antennas Using a Metallic EBG Structure and Multiple Sources Feeding for Base Station Applications

    Get PDF
    This work aims to study and design base station antennas with metallic electromagnetic band gap (EBG) materials able to create a sectoral radiation pattern presenting at least a 60∘ beamwidth. The use of metallic structures offers a new approach to industrial partners seeking to reduce costs and facilitate design procedures. A new method allowing the improvement of both the directivity and the bandwidth by using a printed antenna array is studied
    corecore