3,113 research outputs found

    Magnetometry with nitrogen-vacancy defects in diamond

    Get PDF
    The isolated electronic spin system of the Nitrogen-Vacancy (NV) centre in diamond offers unique possibilities to be employed as a nanoscale sensor for detection and imaging of weak magnetic fields. Magnetic imaging with nanometric resolution and field detection capabilities in the nanotesla range are enabled by the atomic-size and exceptionally long spin-coherence times of this naturally occurring defect. The exciting perspectives that ensue from these characteristics have triggered vivid experimental activities in the emerging field of "NV magnetometry". It is the purpose of this article to review the recent progress in high-sensitivity nanoscale NV magnetometry, generate an overview of the most pertinent results of the last years and highlight perspectives for future developments. We will present the physical principles that allow for magnetic field detection with NV centres and discuss first applications of NV magnetometers that have been demonstrated in the context of nano magnetism, mesoscopic physics and the life sciences.Comment: Review article, 28 pages, 16 figure

    Magnetic-field-dependent photodynamics of single NV defects in diamond: Application to qualitative all-optical magnetic imaging

    Get PDF
    Magnetometry and magnetic imaging with nitrogen-vacancy (NV) defects in diamond rely on the optical detection of electron spin resonance (ESR). However, this technique is inherently limited to magnetic fields that are weak enough to avoid electron spin mixing. Here we focus on the high off-axis magnetic field regime for which spin mixing alters the NV defect spin dynamics. We first study in a quantitative manner the dependence of the NV defect optical properties on the magnetic field vector B. Magnetic-field-dependent time-resolved photoluminescence (PL) measurements are compared to a seven-level model of the NV defect that accounts for field-induced spin mixing. The model reproduces the decreases in (i) ESR contrast, (ii) PL intensity and (iii) excited level lifetime with an increasing off-axis magnetic field. We next demonstrate that those effects can be used to perform all-optical magnetic imaging in the high off-axis magnetic field regime. Using a scanning NV defect microscope, we map the stray field of a magnetic hard disk through both PL and fluorescence lifetime imaging. This all-optical method for high magnetic field imaging at the nanoscale might be of interest in the field of nanomagnetism, where samples producing fields in excess of several tens of milliteslas are typical

    Quantitative stray field imaging of a magnetic vortex core

    Get PDF
    Thin-film ferromagnetic disks present a vortex spin structure whose dynamics, added to the small size (~10 nm) of their core, earned them intensive study. Here we use a scanning nitrogen-vacancy (NV) center microscope to quantitatively map the stray magnetic field above a 1 micron-diameter disk of permalloy, unambiguously revealing the vortex core. Analysis of both probe-to-sample distance and tip motion effects through stroboscopic measurements, allows us to compare directly our quantitative images to micromagnetic simulations of an ideal structure. Slight perturbations with respect to the perfect vortex structure are clearly detected either due to an applied in-plane magnetic field or imperfections of the magnetic structures. This work demonstrates the potential of scanning NV microscopy to map tiny stray field variations from nanostructures, providing a nanoscale, non-perturbative detection of their magnetic texture.Comment: 5 pages, 4 figure

    Different methods of evaluation of Monilinia laxa on apricot flowers and branches

    Get PDF
    - Organic apricot production is currently not profitable. - The main obstacle to sustainable profitability is brown rot caused by the fungus Monilinia laxa (Aderh. & Ruhl). - In the current apricot germplasm no source of total resistance has been shown, but some varieties are expressing interesting levels of tolerance. - A good evaluation of the M. laxa symptoms is essential for a precise diagnosis of the infection and to appreciate differences between tolerant and susceptible varieties and genotypes

    Measuring the magnetic moment density in patterned ultrathin ferromagnets with submicron resolution

    Get PDF
    We present a new approach to infer the surface density of magnetic moments IsI_s in ultrathin ferromagnetic films with perpendicular anisotropy. It relies on quantitative stray field measurements with an atomic-size magnetometer based on the nitrogen-vacancy center in diamond. The method is applied to microstructures patterned in a 1-nm-thick film of CoFeB. We report measurements of IsI_s with a few percent uncertainty and a spatial resolution in the range of (100(100 nm)2^2, an improvement by several orders of magnitude over existing methods. As an example of application, we measure the modifications of IsI_s induced by local irradiation with He+^+ ions in an ultrathin ferromagnetic wire. This method offers a new route to study variations of magnetic properties at the nanoscale.Comment: 9 pages and 7 figures including main text and Supplemental Informatio

    Magnetic imaging with an ensemble of Nitrogen Vacancy centers in diamond

    Full text link
    The nitrogen-vacancy (NV) color center in diamond is an atom-like system in the solid-state which specific spin properties can be efficiently used as a sensitive magnetic sensor. An external magnetic field induces Zeeman shifts of the NV center levels which can be measured using Optically Detected Magnetic Resonance (ODMR). In this work, we exploit the ODMR signal of an ensemble of NV centers in order to quantitatively map the vectorial structure of a magnetic field produced by a sample close to the surface of a CVD diamond hosting a thin layer of NV centers. The reconstruction of the magnetic field is based on a maximum-likelihood technique which exploits the response of the four intrinsic orientations of the NV center inside the diamond lattice. The sensitivity associated to a 1 {\mu}m^2 area of the doped layer, equivalent to a sensor consisting of approximately 10^4 NV centers, is of the order of 2 {\mu}T/sqrt{Hz}. The spatial resolution of the imaging device is 400 nm, limited by the numerical aperture of the optical microscope which is used to collect the photoluminescence of the NV layer. The versatility of the sensor is illustrated by the accurate reconstruction of the magnetic field created by a DC current inside a copper wire deposited on the diamond sample.Comment: 11 pages, 5 figures, figure 4 added, results unchange

    Spin relaxometry of single nitrogen-vacancy defects in diamond nanocrystals for magnetic noise sensing

    Get PDF
    We report an experimental study of the longitudinal relaxation time (T1T_1) of the electron spin associated with single nitrogen-vacancy (NV) defects hosted in nanodiamonds (ND). We first show that T1T_1 decreases over three orders of magnitude when the ND size is reduced from 100 to 10 nm owing to the interaction of the NV electron spin with a bath of paramagnetic centers lying on the ND surface. We next tune the magnetic environment by decorating the ND surface with Gd3+^{3+} ions and observe an efficient T1T_{1}-quenching, which demonstrates magnetic noise sensing with a single electron spin. We estimate a sensitivity down to 14\approx 14 electron spins detected within 10 s, using a single NV defect hosted in a 10-nm-size ND. These results pave the way towards T1T_1-based nanoscale imaging of the spin density in biological samples.Comment: Main text with 4 figures together with supplemental informatio

    A V-shape superconducting artificial atom based on two inductively coupled transmons

    Full text link
    Circuit quantum electrodynamics systems are typically built from resonators and two-level artificial atoms, but the use of multi-level artificial atoms instead can enable promising applications in quantum technology. Here we present an implementation of a Josephson junction circuit dedicated to operate as a V-shape artificial atom. Based on a concept of two internal degrees of freedom, the device consists of two transmon qubits coupled by an inductance. The Josephson nonlinearity introduces a strong diagonal coupling between the two degrees of freedom that finds applications in quantum non-demolition readout schemes, and in the realization of microwave cross-Kerr media based on superconducting circuits.Comment: 5 pages, 3 figure

    Multifocal High-Grade Pancreatic Precursor Lesions: A Case Series and Management Recommendations

    Get PDF
    Background: The risk of developing invasive cancer in the remnant pancreas after resection of multifocal high-grade pancreatic precursor lesions is not well known. We report three patients who were followed up after resection of multifocal high-grade pancreatic intraepithelial neoplasia (PanIN)-3 or intraductal papillary mucinous neoplasia (IPMN), two of whom eventually developed invasive carcinoma. Presentation: 1) 68-year-old woman who had a laparoscopic distal pancreatectomy for multifocal mixed-type IPMN, identified as high-grade on final pathology, with negative surgical margins. During semiannual monitoring, eight years from the first surgery, the patient developed suspicious features prompting surgical resection of the body with final pathology revealing invasive ductal adenocarcinoma in the setting of IPMN. 2) 48-year-old woman who had a distal pancreatectomy for severe acute/chronic symptomatic pancreatitis, with final pathology revealing multifocal high-grade PanIN-3, with negative surgical margins. Despite semiannual monitoring, two years from the first surgery, the patient developed pancreatic adenocarcinoma with liver metastasis. 3) 55-year-old woman who had a Whipple procedure for symptomatic chronic pancreatitis, with multifocal PanIN-3 on final pathology. The patient underwent completion pancreatectomy due to symptomatology and her high-risk profile, with final pathology confirming multifocal PanIN-3. Conclusion: Multifocal high-grade dysplastic lesions of the pancreas might benefit from surgical resection
    corecore