150 research outputs found
Recommended from our members
Dose volume histogram analysis of normal structures associated with accelerated partial breast irradiation delivered by high dose rate brachytherapy and comparison with whole breast external beam radiotherapy fields
<p>Abstract</p> <p>Purpose</p> <p>To assess the radiation dose delivered to the heart and ipsilateral lung during accelerated partial breast brachytherapy using a MammoSite™ applicator and compare to those produced by whole breast external beam radiotherapy (WBRT).</p> <p>Materials and methods</p> <p>Dosimetric analysis was conducted on patients receiving MammoSite breast brachytherapy following conservative surgery for invasive ductal carcinoma. Cardiac dose was evaluated for patients with left breast tumors with a CT scan encompassing the entire heart. Lung dose was evaluated for patients in whom the entire lung was scanned. The prescription dose of 3400 cGy was 1 cm from the balloon surface. MammoSite dosimetry was compared to simulated WBRT fields with and without radiobiological correction for the effects of dose and fractionation. Dose parameters such as the volume of the structure receiving 10 Gy or more (V10) and the dose received by 20 cc of the structure (D20), were calculated as well as the maximum and mean doses received.</p> <p>Results</p> <p>Fifteen patients were studied, five had complete lung data and six had left-sided tumors with complete cardiac data. Ipsilateral lung volumes ranged from 925–1380 cc. Cardiac volumes ranged from 337–551 cc. MammoSite resulted in a significantly lower percentage lung V30 and lung and cardiac V20 than the WBRT fields, with and without radiobiological correction.</p> <p>Conclusion</p> <p>This study gives low values for incidental radiation received by the heart and ipsilateral lung using the MammoSite applicator. The volume of heart and lung irradiated to clinically significant levels was significantly lower with the MammoSite applicator than using simulated WBRT fields of the same CT data sets.</p> <p>Trial registration</p> <p>Dana Farber Trial Registry number 03-179</p
Recommended from our members
Near-infrared fluorescence imaging platform for quantifying in vivo nanoparticle diffusion from drug loaded implants
Drug loaded implants are a new, versatile technology platform to deliver a localized payload of drugs for various disease models. One example is the implantable nanoplatform for chemo-radiation therapy where inert brachytherapy spacers are replaced by spacers doped with nanoparticles (NPs) loaded with chemotherapeutics and placed directly at the disease site for long-term localized drug delivery. However, it is difficult to directly validate and optimize the diffusion of these doped NPs in in vivo systems. To better study this drug release and diffusion, we developed a custom macroscopic fluorescence imaging system to visualize and quantify fluorescent NP diffusion from spacers in vivo. To validate the platform, we studied the release of free fluorophores, and 30 nm and 200 nm NPs conjugated with the same fluorophores as a model drug, in agar gel phantoms in vitro and in mice in vivo. Our data verified that the diffusion volume was NP size-dependent in all cases. Our near-infrared imaging system provides a method by which NP diffusion from implantable nanoplatform for chemo-radiation therapy spacers can be systematically optimized (eg, particle size or charge) thereby improving treatment efficacy of the platform
Bioactive sol-gel glasses at the atomic scale: the complementary use of advanced probe and computer modelling methods
Sol-gel synthesised bioactive glasses may be formed via a hydrolysis condensation reaction, silica being introduced in the form of tetraethyl orthosilicate (TEOS) and calcium is typically added in the form of calcium nitrate. The synthesis reaction proceeds in an aqueous environment; the resultant gel is dried, before stabilisation by heat treatment. These
materials, being amorphous, are complex at the level of their atomic-scale structure, but their bulk properties may only be properly understood on the basis of that structural insight. Thus, a full understanding of their structure : property relationship may only be achieved
through the application of a coherent suite of leading-edge experimental probes, coupled with the cogent use of advanced computer simulation methods. Using as an exemplar a calcia-silica sol-gel glass of the kind developed by Larry Hench, to whose memory this paper is dedicated, we illustrate the successful use of high-energy x-ray and neutron scattering (diffraction) methods, magic-angle spinning solid state NMR, and molecular dynamics simulation as components to a powerful methodology for the study of amorphous materials
Recommended from our members
Numerical analysis of wavefront aberration correction using multielectrode electrowetting-based devices.
We present numerical simulations of multielectrode electrowetting devices used in a novel optical design to correct wavefront aberration. Our optical system consists of two multielectrode devices, preceded by a single fixed lens. The multielectrode elements function as adaptive optical devices that can be used to correct aberrations inherent in many imaging setups, biological samples, and the atmosphere. We are able to accurately simulate the liquid-liquid interface shape using computational fluid dynamics. Ray tracing analysis of these surfaces shows clear evidence of aberration correction. To demonstrate the strength of our design, we studied three different input aberrations mixtures that include astigmatism, coma, trefoil, and additional higher order aberration terms, with amplitudes as large as one wave at 633 nm
Mycobacterium tuberculosis Responds to Chloride and pH as Synergistic Cues to the Immune Status of its Host Cell
PubMed ID: 23592993This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Recommended from our members
Variability in MRI vs. ultrasound measures of prostate volume and its impact on treatment recommendations for favorable-risk prostate cancer patients: a case series
Background: Prostate volume can affect whether patients qualify for brachytherapy (desired size ≥20 mL and ≤60 mL) and/or active surveillance (desired PSA density ≤0.15 for very low risk disease). This study examines variability in prostate volume measurements depending on imaging modality used (ultrasound versus MRI) and volume calculation technique (contouring versus ellipsoid) and quantifies the impact of this variability on treatment recommendations for men with favorable-risk prostate cancer. Methods: We examined 70 patients who presented consecutively for consideration of brachytherapy for favorable-risk prostate cancer who had volume estimates by three methods: contoured axial ultrasound slices, ultrasound ellipsoid (height × width × length × 0.523) calculation, and endorectal coil MRI (erMRI) ellipsoid calculation. Results: Average gland size by the contoured ultrasound, ellipsoid ultrasound, and erMRI methods were 33.99, 37.16, and 39.62 mLs, respectively. All pairwise comparisons between methods were statistically significant (all p < 0.015). Of the 66 patients who volumetrically qualified for brachytherapy on ellipsoid ultrasound measures, 22 (33.33%) did not qualify on ellipsoid erMRI or contoured ultrasound measures. 38 patients (54.28%) had PSA density ≤0.15 ng/dl as calculated using ellipsoid ultrasound volumes, compared to 34 (48.57%) and 38 patients (54.28%) using contoured ultrasound and ellipsoid erMRI volumes, respectively. Conclusions: The ultrasound ellipsoid and erMRI ellipsoid methods appeared to overestimate ultrasound contoured volume by an average of 9.34% and 16.57% respectively. 33.33% of those who qualified for brachytherapy based on ellipsoid ultrasound volume would be disqualified based on ultrasound contoured and/or erMRI ellipsoid volume. As treatment recommendations increasingly rely on estimates of prostate size, clinicians must consider method of volume estimation
An evaluation of the variability of tumor-shape definition derived by experienced observers from CT images of supraglottic carcinomas (ACRIN protocol 6658)
Accurate target definition is considered essential for sophisticated, image-guided radiation therapy; however, relatively little information has been reported that measures our ability to identify the precise shape of targets accurately. We decided to assess the manner in which eight “experts” interpreted the size and shape of tumors based on “real life” contrast-enhanced CT scans
PsyCog:A computerised mini battery for assessing cognition in psychosis
Despite the functional impact of cognitive deficit in people with psychosis, objective cognitive assessment is not typically part of routine clinical care. This is partly due to the length of traditional assessments and the need for a highly trained administrator. Brief, automated computerised assessments could help to address this issue. We present data from an evaluation of PsyCog, a computerised, non-verbal, mini battery of cognitive tests. Healthy Control (HC) ( N = 135), Clinical High Risk (CHR) ( N = 233), and First Episode Psychosis (FEP) ( N = 301) participants from a multi-centre prospective study were assessed at baseline, 6 months, and 12 months. PsyCog was used to assess cognitive performance at baseline and at up to two follow-up timepoints. Mean total testing time was 35.95 min (SD = 2.87). Relative to HCs, effect sizes of performance impairments were medium to large in FEP patients (composite score G = 1.21, subtest range = 0.52-0.88) and small to medium in CHR patients (composite score G = 0.59, subtest range = 0.18-0.49). Site effects were minimal, and test-retest reliability of the PsyCog composite was good (ICC = 0.82-0.89), though some practice effects and differences in data completion between groups were found. The present implementation of PsyCog shows it to be a useful tool for assessing cognitive function in people with psychosis. Computerised cognitive assessments have the potential to facilitate the evaluation of cognition in psychosis in both research and in clinical care, though caution should still be taken in terms of implementation and study design. </p
Autochthonous heritage languages and social media:writing and bilingual practices in Low German on Facebook
This article analyses how speakers of an autochthonous heritage language (AHL) make use of digital media, through the example of Low German, a regional language used by a decreasing number of speakers mainly in northern Germany. The focus of the analysis is on Web 2.0 and its interactive potential for individual speakers. The study therefore examines linguistic practices on the social network site Facebook, with special emphasis on language choice, bilingual practices and writing in the autochthonous heritage language. The findings suggest that social network sites such as Facebook have the potential to provide new mediatized spaces for speakers of an AHL that can instigate sociolinguistic change
- …