1,156 research outputs found

    Manipulation of foot strike and footwear increases Achilles tendon loading during running

    Get PDF
    This is the author accepted manuscript. The final version is available from SAGE Publications via the DOI in this record.Background: The Achilles tendon is the most common site of tendon overuse injury in humans. There has been a recent interest in running with a forefoot strike pattern and in minimal shoes, yet evidence is currently limited regarding the combined influence of foot strike and footwear on Achilles tendon loading. Purpose: To investigate the influence of both foot strike and footwear on Achilles tendon loading in habitual rearfoot strike runners. Study Design: Crossover study design Methods: Synchronised kinematic and force data were collected from 22 habitual rearfoot strikers (11 male), who habitually run in non-minimal running shoes, during overground running at 3.6 m.s-1. Participants ran in three different footwear conditions (standard running shoe; minimal running shoe; barefoot) with both a rearfoot strike (RFS) and an imposed forefoot strike (FFS) in each footwear condition. Achilles tendon loading was estimated using inverse dynamics, where the Achilles tendon moment arm was determined using a regression equation. Conditions were compared using a two-way repeated measures ANOVA. Results: Achilles tendon impulse was greater when running with a FFS than a RFS in minimal shoes. Achilles tendon loading rates were higher when running either in minimal shoes or barefoot than in standard shoes, regardless of foot strike. Conclusions: In runners who habitually rearfoot strike in standard running shoes, running in minimal shoes or barefoot increased the rate of tendon loading, and running with a forefoot strike in minimal shoes increased the magnitude of tendon loading. Transitioning to these running conditions may increase the risk of tendinopathy. What is known about this subject? It has been shown that when running with a forefoot strike compared with a rearfoot strike, the internal ankle plantar flexor moment increases, but there are conflicting findings regarding whether this results in an increase in Achilles tendon force. Some of these findings may have been confounded by footwear. What this study adds to existing knowledge This study considered the influence of both foot strike and footwear on Achilles tendon loading during running, as well as their interactive effect. It has added to the knowledge in this area by identifying that foot strike influences the magnitude of loading, whereas footwear influences the rate, amongst habitual rearfoot strikers who are accustomed to running in standard running footwear

    Footwear matters: influence of footwear and foot strike on load rates during running

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.This is a non-final version of an article published in final form in Medicine and Science in Sports 22 and Exercise, 2016 Jul 6.INTRODUCTION: Running with a forefoot strike (FFS) pattern has been suggested to reduce the risk of overuse running injuries, due to a reduced vertical loadrate compared with rearfoot strike (RFS) running. However, resultant loadrate has been reported to be similar between foot strikes when running in traditional shoes, leading to questions regarding the value of running with a FFS. The influence of minimal footwear on the resultant loadrate has not been considered. This study aimed to compare component and resultant instantaneous loadrate (ILR) between runners with different foot strike patterns in their habitual footwear conditions. METHODS: 29 injury-free participants (22 males, 7 females) ran at 3.13m.s along a 30m runway, with their habitual foot strike and footwear condition. Ground reaction force data were collected. Peak ILR values were compared between three conditions; those who habitually run with a RFS in standard shoes, with a FFS in standard shoes, and with a FFS in minimal shoes. RESULTS: Peak resultant, vertical, lateral and medial ILR were lower (P < 0.001) when running in minimal shoes with a FFS than in standard shoes with either foot strike. When running with a FFS, peak posterior ILR were lower (P < 0.001) in minimal than standard shoes. CONCLUSIONS: When running in a standard shoe, peak resultant and component instantaneous loadrates were similar between footstrike patterns. However, loadrates were lower when running in minimal shoes with a FFS, compared with running in standard shoes with either foot strike. Therefore, it appears that footwear alters the loadrates during running, even with similar foot strike patterns

    Footwear matters: influence of footwear and foot strike on load rates during running

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.This is a non-final version of an article published in final form in Medicine and Science in Sports 22 and Exercise, 2016 Jul 6.INTRODUCTION: Running with a forefoot strike (FFS) pattern has been suggested to reduce the risk of overuse running injuries, due to a reduced vertical loadrate compared with rearfoot strike (RFS) running. However, resultant loadrate has been reported to be similar between foot strikes when running in traditional shoes, leading to questions regarding the value of running with a FFS. The influence of minimal footwear on the resultant loadrate has not been considered. This study aimed to compare component and resultant instantaneous loadrate (ILR) between runners with different foot strike patterns in their habitual footwear conditions. METHODS: 29 injury-free participants (22 males, 7 females) ran at 3.13m.s along a 30m runway, with their habitual foot strike and footwear condition. Ground reaction force data were collected. Peak ILR values were compared between three conditions; those who habitually run with a RFS in standard shoes, with a FFS in standard shoes, and with a FFS in minimal shoes. RESULTS: Peak resultant, vertical, lateral and medial ILR were lower (P < 0.001) when running in minimal shoes with a FFS than in standard shoes with either foot strike. When running with a FFS, peak posterior ILR were lower (P < 0.001) in minimal than standard shoes. CONCLUSIONS: When running in a standard shoe, peak resultant and component instantaneous loadrates were similar between footstrike patterns. However, loadrates were lower when running in minimal shoes with a FFS, compared with running in standard shoes with either foot strike. Therefore, it appears that footwear alters the loadrates during running, even with similar foot strike patterns

    Estimates of tibial shock magnitude in men and women at the start and end of a military drill training programme

    Get PDF
    This is the author accepted manuscript. The final version is available from Oxford University Press via the DOI in this record.Introduction Foot drill is a key component of military training and is characterized by frequent heel stamping, likely resulting in high tibial shock magnitudes. Higher tibial shock during running has previously been associated with risk of lower limb stress fractures, which are prevalent among military populations. Quantification of tibial shock during drill training is, therefore, warranted. This study aimed to provide estimates of tibial shock during military drill in British Army Basic training. The study also aimed to compare values between men and women, and to identify any differences between the first and final sessions of training. Materials and Methods Tibial accelerometers were secured on the right medial, distal shank of 10 British Army recruits (n = 5 men; n = 5 women) throughout a scheduled drill training session in week 1 and week 12 of basic military training. Peak positive accelerations, the average magnitude above given thresholds, and the rate at which each threshold was exceeded were quantified. Results Mean (SD) peak positive acceleration was 20.8 (2.2) g across all sessions, which is considerably higher than values typically observed during high impact physical activity. Magnitudes of tibial shock were higher in men than women, and higher in week 12 compared with week 1 of training. Conclusions This study provides the first estimates of tibial shock magnitude during military drill training in the field. The high values suggest that military drill is a demanding activity and this should be considered when developing and evaluating military training programs. Further exploration is required to understand the response of the lower limb to military drill training and the etiology of these responses in the development of lower limb stress fractures.The study was sponsored by the Headquarters Army Recruitment and Training Division, U

    A narrow bimalleolar width is a risk factor for ankle inversion injury in male military recruits: A prospective study

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.Background: Ankle inversion injuries are one of the most common and burdensome injuries in athletic populations. Research that prospectively identifies characteristics associated with this injury is lacking. This prospective study compared baseline anthropometric and biomechanical gait characteristics of military recruits who sustained an ankle inversion injury during training, with those who remained injury-free. Methods: Bilateral plantar pressure and three-dimensional lower limb kinematics were recorded in 1065 male, injury-free military recruits, during barefoot running. Injuries that occurred during the 32-week recruit training programme were subsequently recorded. Data were compared between recruits who sustained an ankle inversion injury during training (n=27) and a sample (n=120) of those who completed training injury-free. A logistic regression analysis was used to identify risk factors for this injury. Findings: A narrower bimalleolar width and an earlier peak pressure under the fifth metatarsal were predictors of ankle inversion injury. Those who sustained an ankle inversion injury also had a lower body mass, body mass index, and a smaller calf girth than those who completed training injury-free. Interpretation: Anthropometric and dynamic gait characteristics have been identified that may predispose recruits to an ankle inversion injury during Royal Marine recruit training, allowing identification of recruits at higher risk at the start of training

    Estimating tibial stress throughout the duration of a treadmill run

    Get PDF
    This is the author accepted manuscript. The final version is available from Lippincott, Williams & Wilkins via the DOI in this record.Introduction: Stress fractures of the tibia are a problematic injury amongst runners of all levels. Quantifying tibial stress using a modelling approach provides an alternative to invasive assessments that may be used to detect changes in tibial stress during running. This study aimed to assess the repeatability of a tibial stress model and to use this model to quantify changes in tibial stress that occur throughout the course of a 40-minute prolonged treadmill run. Methods: Synchronised force and kinematic data were collected during prolonged treadmill running from fourteen recreational male rearfoot runners on two separate occasions. During each session, participants ran at their preferred speed for two consecutive 20-minute runs, separated by a 2-minute pause. The tibia was modelled as a hollow ellipse and bending moments and stresses at the distal 1/3 of the tibia were estimated using beam theory combined with inverse dynamics and musculoskeletal modelling. Results: Intraclass correlation coefficients indicated good-to-excellent repeatability for peak stress values between sessions. Peak anterior and posterior stresses increased following 20 minutes of prolonged treadmill running and were 15% and 12% greater respectively after 40 minutes of running compared with the start of the run. Conclusion: The hollow elliptical tibial model presented is a repeatable tool that can be utilised to assess within-participant changes in peak tibial stress during running. The increased stresses observed during a prolonged treadmill run may have implications for the development of tibial stress fracture.Brooks Running Company, Seattle, WA, USA

    Exploring 4D Quantum Hall Physics with a 2D Topological Charge Pump

    Get PDF
    The discovery of topological states of matter has profoundly augmented our understanding of phase transitions in physical systems. Instead of local order parameters, topological phases are described by global topological invariants and are therefore robust against perturbations. A prominent example thereof is the two-dimensional integer quantum Hall effect. It is characterized by the first Chern number which manifests in the quantized Hall response induced by an external electric field. Generalizing the quantum Hall effect to four-dimensional systems leads to the appearance of a novel non-linear Hall response that is quantized as well, but described by a 4D topological invariant - the second Chern number. Here, we report on the first observation of a bulk response with intrinsic 4D topology and the measurement of the associated second Chern number. By implementing a 2D topological charge pump with ultracold bosonic atoms in an angled optical superlattice, we realize a dynamical version of the 4D integer quantum Hall effect. Using a small atom cloud as a local probe, we fully characterize the non-linear response of the system by in-situ imaging and site-resolved band mapping. Our findings pave the way to experimentally probe higher-dimensional quantum Hall systems, where new topological phases with exotic excitations are predicted

    Quantum to Classical Transition in a Single-Ion Laser

    Full text link
    Stimulated emission of photons from a large number of atoms into the mode of a strong light field is the principle mechanism for lasing in "classical" lasers. The onset of lasing is marked by a threshold which can be characterised by a sharp increase in photon flux as a function of external pumping strength. The same is not necessarily true for the fundamental building block of a laser: a single trapped atom interacting with a single optical radiation mode. It has been shown that such a "quantum" laser can exhibit thresholdless lasing in the regime of strong coupling between atom and radiation field. However, although theoretically predicted, a threshold at the single-atom level could not be experimentally observed so far. Here, we demonstrate and characterise a single-atom laser with and without threshold behaviour by changing the strength of atom-light field coupling. We observe the establishment of a laser threshold through the accumulation of photons in the optical mode even for a mean photon number substantially lower than for the classical case. Furthermore, self-quenching occurs for very strong external pumping and constitutes an intrinsic limitation of single-atom lasers. Moreover, we find that the statistical properties of the emitted light can be adjusted for weak external pumping, from the quantum to the classical domain. Our observations mark an important step towards fundamental understanding of laser operation in the few-atom limit including systems based on semiconductor quantum dots or molecules.Comment: 19 pages, 4 figures, 10 pages supplement, accepted by Nature Physic

    Validating child vaccination status in a demographic surveillance system using data from a clinical cohort study: evidence from rural South Africa

    Get PDF
    &lt;p&gt;&lt;b&gt;Background:&lt;/b&gt; Childhood vaccination coverage can be estimated from a range of sources. This study aims to validate vaccination data from a longitudinal population-based demographic surveillance system (DSS) against data from a clinical cohort study.&lt;/p&gt; &lt;p&gt;&lt;b&gt;Methods:&lt;/b&gt; The sample includes 821 children in the Vertical Transmission cohort Study (VTS), who were born between December 2001 and April 2005, and were matched to the Africa Centre DSS, in northern KwaZulu-Natal. Vaccination information in the surveillance was collected retrospectively, using standardized questionnaires during bi-annual household visits, when the child was 12 to 23 months of age. DSS vaccination information was based on extraction from a vaccination card or, if the card was not available, on maternal recall. In the VTS, vaccination data was collected at scheduled maternal and child clinic visits when a study nurse administered child vaccinations. We estimated the sensitivity of the surveillance in detecting vaccinations conducted as part of the VTS during these clinic visits.&lt;/p&gt; &lt;p&gt;&lt;b&gt;Results:&lt;/b&gt; Vaccination data in matched children in the DSS was based on the vaccination card in about two-thirds of the cases and on maternal recall in about one-third. The sensitivity of the vaccination variables in the surveillance was high for all vaccines based on either information from a South African Road-to-Health (RTH) card (0.94-0.97) or maternal recall (0.94-0.98). Addition of maternal recall to the RTH card information had little effect on the sensitivity of the surveillance variable (0.95-0.97). The estimates of sensitivity did not vary significantly, when we stratified the analyses by maternal antenatal HIV status. Addition of maternal recall of vaccination status of the child to the RTH card information significantly increased the proportion of children known to be vaccinated across all vaccines in the DSS.&lt;/p&gt; &lt;p&gt;&lt;b&gt;Conclusion:&lt;/b&gt; Maternal recall performs well in identifying vaccinated children aged 12-23 months (both in HIV-infected and HIV-uninfected mothers), with sensitivity similar to information extracted from vaccination cards. Information based on both maternal recall and vaccination cards should be used if the aim is to use surveillance data to identify children who received a vaccination.&lt;/p&gt

    The biofilm matrix scaffold of Pseudomonas aeruginosa contains G-quadruplex extracellular DNA structures.

    Full text link
    Extracellular DNA, or eDNA, is recognised as a critical biofilm component; however, it is not understood how it forms networked matrix structures. Here, we isolate eDNA from static-culture Pseudomonas aeruginosa biofilms using ionic liquids to preserve its biophysical signatures of fluid viscoelasticity and the temperature dependency of DNA transitions. We describe a loss of eDNA network structure as resulting from a change in nucleic acid conformation, and propose that its ability to form viscoelastic structures is key to its role in building biofilm matrices. Solid-state analysis of isolated eDNA, as a proxy for eDNA structure in biofilms, reveals non-canonical Hoogsteen base pairs, triads or tetrads involving thymine or uracil, and guanine, suggesting that the eDNA forms G-quadruplex structures. These are less abundant in chromosomal DNA and disappear when eDNA undergoes conformation transition. We verify the occurrence of G-quadruplex structures in the extracellular matrix of intact static and flow-cell biofilms of P. aeruginosa, as displayed by the matrix to G-quadruplex-specific antibody binding, and validate the loss of G-quadruplex structures in vivo to occur coincident with the disappearance of eDNA fibres. Given their stability, understanding how extracellular G-quadruplex structures form will elucidate how P. aeruginosa eDNA builds viscoelastic networks, which are a foundational biofilm property
    • …
    corecore