6 research outputs found

    Effectiveness and safety of transcatheter aortic valve replacement in elderly people with severe aortic stenosis with different types of heart failure.

    Get PDF
    Impaired left ventricular function is an independent predictor of adverse clinical outcomes in patients with aortic stenosis. The aim of this study is to evaluate the short-term changes of echocardiographic parameters, New York Heart Association (NYHA) class and B-type natriuretic peptide (BNP) level and adverse events amongst patients with heart failure (HF) after transcatheter aortic valve replacement (TAVR) procedure. This was a retrospective cohort study conducted at affiliated Yantai Yuhuangding Hospital of Qingdao University between September 2017 and September 2022. TAVR cases were stratified into three groups [heart failure with reduced ejection fraction (HFrEF), heart failure with mildly reduced ejection fraction (HFmrEF), heart failure with preserved ejection fraction (HFpEF)] by left ventricular ejection fraction (LVEF). Baseline characteristics, changes in echocardiographic parameters (1 week and 1 month), BNP (1 month), and NYHA class (6 months) post-TAVR were compared across the three groups. Meanwhile, we observed the adverse events of the patients after TAVR. A total of 96 patients were included, of whom 15 (15.6%) had HFrEF, 15 (15.6%) had HFmrEF, and 66 (68.8%) had HFpEF. Compared to the HFpEF subgroup, patients in the HFrEF subgroup were younger (p < 0.05), and with a higher BNP (p < 0.05). The left ventricular end-diastolic dimension (LVEDD) in HFrEF group decreased significantly after TAVR. HFmrEF and HFrEF patients showed significant improvements in LVEF after TAVR. The pulmonary artery systolic pressure (PASP), aortic valve peak gradient (AVPG) and aortic valve peak gradient (V ) decreased significantly 1 month after TAVR in all three groups compared to the baseline (all p < 0.05). BNP significantly reduced in HFrEF group compared to HFpEF patients after TAVR (p < 0.05). The majority of patients experienced an improvement at least one NYHA class in all three groups 6 months post-TAVR. There is no significant increase in the risk of adverse events in the HFrEF group. Patients who underwent TAVR achieved significant improvements in BNP, NYHA class, LVEDD, LVEF, and PASP across the three HF classes, with a more rapid and pronounced improvement in the HFrEF and HFmrEF groups. Complication rates were low in the different HF groups. There is no significant increase in the risk of periprocedural complications in the HFrEF and HFmrEF groups. [Abstract copyright: © 2023. The Author(s).

    Effectiveness and safety of transcatheter aortic valve replacement in elderly people with severe aortic stenosis with different types of heart failure

    Get PDF
    Background: Impaired left ventricular function is an independent predictor of adverse clinical outcomes in patients with aortic stenosis. The aim of this study is to evaluate the short-term changes of echocardiographic parameters, New York Heart Association (NYHA) class and B-type natriuretic peptide (BNP) level and adverse events amongst patients with heart failure (HF) after transcatheter aortic valve replacement (TAVR) procedure. Methods: This was a retrospective cohort study conducted at affiliated Yantai Yuhuangding Hospital of Qingdao University between September 2017 and September 2022. TAVR cases were stratified into three groups [heart failure with reduced ejection fraction (HFrEF), heart failure with mildly reduced ejection fraction (HFmrEF), heart failure with preserved ejection fraction (HFpEF)] by left ventricular ejection fraction (LVEF). Baseline characteristics, changes in echocardiographic parameters (1 week and 1 month), BNP (1 month), and NYHA class (6 months) post-TAVR were compared across the three groups. Meanwhile, we observed the adverse events of the patients after TAVR. Results: A total of 96 patients were included, of whom 15 (15.6%) had HFrEF, 15 (15.6%) had HFmrEF, and 66 (68.8%) had HFpEF. Compared to the HFpEF subgroup, patients in the HFrEF subgroup were younger (p < 0.05), and with a higher BNP (p < 0.05). The left ventricular end-diastolic dimension (LVEDD) in HFrEF group decreased significantly after TAVR. HFmrEF and HFrEF patients showed significant improvements in LVEF after TAVR. The pulmonary artery systolic pressure (PASP), aortic valve peak gradient (AVPG) and aortic valve peak gradient (Vmax) decreased significantly 1 month after TAVR in all three groups compared to the baseline (all p < 0.05). BNP significantly reduced in HFrEF group compared to HFpEF patients after TAVR (p < 0.05). The majority of patients experienced an improvement at least one NYHA class in all three groups 6 months post-TAVR. There is no significant increase in the risk of adverse events in the HFrEF group. Conclusions: Patients who underwent TAVR achieved significant improvements in BNP, NYHA class, LVEDD, LVEF, and PASP across the three HF classes, with a more rapid and pronounced improvement in the HFrEF and HFmrEF groups. Complication rates were low in the different HF groups. There is no significant increase in the risk of periprocedural complications in the HFrEF and HFmrEF groups

    LDL-C: An important independent risk factor for new-onset heart block in patients with severe aortic stenosis and heart failure after TAVR

    Get PDF
    Transcatheter aortic valve replacement (TAVR) is an effective alternative treatment for patients with aortic stenosis (AS) who have intermediate to high surgical risk or who are inoperable. However, the incidence of conduction abnormalities is high after TAVR, which can reduce the effectiveness of the surgery. Our research objective is to explore the risk factors of new-onset conduction abnormalities after TAVR, providing reference value for clinical doctors to better prevent and treat conduction abnormalities. Patients who underwent TAVR were divided into those who developed heart block and those who did not. Baseline clinical characteristics, cardiac structural parameters, procedural characteristics, electrocardiogram (ECG) changes before and after TAVR ( = postoperative minus preoperative), and surgical complications were compared. Logistic regression was applied to identify significant risk factors for new-onset heart block. We studied 93 patients, of whom 34.4% developed heart blocks. Univariate logistic regression showed that prior history of malignancy, atrial fibrillation, preoperative high-level total cholesterol and low-density lipoprotein cholesterol (LDL-C), HR, QRS interval, QT interval, and QTc interval were risk factors of new-onset heart block after TAVR. Multivariate analysis showed that preoperative high-level LDL-C and QRS interval remained significant independent risk factors after adjusting for potential confounds. Heart block is the most common complication of TAVR, and its significant independent risk factors include high-level LDL-C and QRS interval. [Abstract copyright: Copyright: © 2023 The Author(s). Published by IMR Press.

    Determinants of device success after transcatheter aortic valve replacement in patients with type-0 bicuspid aortic stenosis

    Get PDF
    BackgroundClinical evidence of transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve was relatively scarce.AimsOur goal was to explore determinants of device success after transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve morphology.MethodsIn this retrospective multicenter analysis, we included 59 patients with symptomatic severe aortic stenosis with type-0 bicuspid aortic valve morphology who underwent transcatheter aortic valve replacement. Type-0 bicuspid aortic valve was identified with multidetector computed tomography scans. The technical success rate was 89.8%, and the device success rate was 81.4%. Patients were divided into a device success group and a device failure group according to Valve Academic Research Consortium- 3 criteria.ResultsWhen we compared the two groups, we found that the ellipticity index of the aortic root and the presence of bulky calcifications at the commissure were statistically different (ellipticity index 35.7 ± 1.7 vs. 29.7 ± 1.1, p = 0.018; bulky calcification at the commissure, 54.5% vs. 4.5%, p &lt; 0.001). Further multivariate logistic analysis showed that bulky calcification at the commissure had a negative correlation with device success (odds ratio 0.030, 95% confidence interval 0.003–0.285, p = 0.002). Yet there was no statistical correlation between the ellipticity index and device success (odds ratio 0.818, 95% confidence interval 0.667–1.003, p = 0.053).ConclusionsThe presence of bulky calcifications at the commissure is negatively correlated with device success after transcatheter aortic valve replacement in patients with type-0 bicuspid aortic valve
    corecore