59 research outputs found
The International Workshop on Osteoarthritis Imaging Knee MRI Segmentation Challenge: A Multi-Institute Evaluation and Analysis Framework on a Standardized Dataset
Purpose: To organize a knee MRI segmentation challenge for characterizing the
semantic and clinical efficacy of automatic segmentation methods relevant for
monitoring osteoarthritis progression.
Methods: A dataset partition consisting of 3D knee MRI from 88 subjects at
two timepoints with ground-truth articular (femoral, tibial, patellar)
cartilage and meniscus segmentations was standardized. Challenge submissions
and a majority-vote ensemble were evaluated using Dice score, average symmetric
surface distance, volumetric overlap error, and coefficient of variation on a
hold-out test set. Similarities in network segmentations were evaluated using
pairwise Dice correlations. Articular cartilage thickness was computed per-scan
and longitudinally. Correlation between thickness error and segmentation
metrics was measured using Pearson's coefficient. Two empirical upper bounds
for ensemble performance were computed using combinations of model outputs that
consolidated true positives and true negatives.
Results: Six teams (T1-T6) submitted entries for the challenge. No
significant differences were observed across all segmentation metrics for all
tissues (p=1.0) among the four top-performing networks (T2, T3, T4, T6). Dice
correlations between network pairs were high (>0.85). Per-scan thickness errors
were negligible among T1-T4 (p=0.99) and longitudinal changes showed minimal
bias (<0.03mm). Low correlations (<0.41) were observed between segmentation
metrics and thickness error. The majority-vote ensemble was comparable to top
performing networks (p=1.0). Empirical upper bound performances were similar
for both combinations (p=1.0).
Conclusion: Diverse networks learned to segment the knee similarly where high
segmentation accuracy did not correlate to cartilage thickness accuracy. Voting
ensembles did not outperform individual networks but may help regularize
individual models.Comment: Submitted to Radiology: Artificial Intelligence; Fixed typo
The Role of the Chemical Shift Difference in a Two-Site Exchange Model Under an On-Resonance Spin-Lock RF Field
The manuscript investigates the role of the chemical shift difference between two exchanging pools under a spin-lock RF field. The results demonstrate that the width of the dispersion of R1rho is determined mainly by the chemical shift difference when the exchange is slow. This work may give a new insight into the spin dynamics under a spin-lock condition and the results may be relevant to the fields using the spin-lock technique, such as protein NMR and MRI contrast.<br /
Subchondral bone microarchitecture analysis in the proximal tibia at 7-T MRI
Background Bone remodels in response to mechanical loads and osteoporosis results from impaired ability of bone to remodel. Bone microarchitecture analysis provides information on bone quality beyond bone mineral density (BMD). Purpose To compare subchondral bone microarchitecture parameters in the medial and lateral tibia plateau in individuals with and without fragility fractures. Material and Methods Twelve female patients (mean age = 58 ± 15 years; six with and six without previous fragility fractures) were examined with dual-energy X-ray absorptiometry (DXA) and 7-T magnetic resonance imaging (MRI) of the proximal tibia. A transverse high-resolution three-dimensional fast low-angle shot sequence was acquired (0.234 × 0.234 × 1 mm). Digital topological analysis (DTA) was applied to the medial and lateral subchondral bone of the proximal tibia. The following DTA-based bone microarchitecture parameters were assessed: apparent bone volume; trabecular thickness; profile-edge-density (trabecular bone erosion parameter); profile-interior-density (intact trabecular rods parameter); plate-to-rod ratio; and erosion index. We compared femoral neck T-scores and bone microarchitecture parameters between patients with and without fragility fracture. Results There was no statistical significant difference in femoral neck T-scores between individuals with and without fracture (-2.4 ± 0.9 vs. -1.8 ± 0.7, P = 0.282). Apparent bone volume in the medial compartment was lower in patients with previous fragility fracture (0.295 ± 0.022 vs. 0.317 ± 0.009; P = 0.016). Profile-edge-density, a trabecular bone erosion parameter, was higher in patients with previous fragility fracture in the medial (0.008 ± 0.003 vs. 0.005 ± 0.001) and lateral compartment (0.008 ± 0.002 vs. 0.005 ± 0.001); both P = 0.025. Other DTA parameters did not differ between groups. Conclusion 7-T MRI and DTA permit detection of subtle changes in subchondral bone quality when differences in BMD are not evident
Bi-exponential 3D-T1ρ mapping of whole brain at 3 T
Abstract Detection of multiple relaxation pools using MRI is useful in a number of neuro-pathologies including multiple sclerosis (MS), Alzheimer’s, and stroke. In this study we evaluate the feasibility of using T1ρ imaging for the detection of bi-exponential decays in the human brain. A prospective T1ρ imaging study was performed on model relaxation phantoms (eggs) and 7 healthy volunteers. The data was fitted using a single pool and a 2-pool model to estimate mono- and bi-exponential T1ρ maps, respectively. Bi-exponential decays were identified in the gray matter (GM) and white matter (WM) of the brain with 40.5% of GM, and 65.1% of WM pixels showing two T1ρ relaxation pools (significance level P < 0.05). Detection of T1ρ based bi-exponential decays in the brain provides complimentary information to T2 based contrast regarding the in vivo micro-environment in the brain
In Vivo Imaging of Signal Decay due to Diffusion in the Internal Field in Human Knee Trabecular Bone
This study presents the first demonstration of the MR signal decay due to diffusion in the internal field (DDIF) for in vivo knee trabecular bone imaging. DDIF contrast was compared with high resolution FLASH, T1, and T2* mapping in healthy volunteers. DDIF maps showed spatial variation, superimposed on a T1 background, reflecting trabecular structure. DDIF and T2* maps showed correlated contrast near dense trabeculae, but their spatial textures differed, suggesting distinct structural sensitivities.clos
In vivo imaging of signal decay due to diffusion in the internal field in human knee trabecular bone
This study presents the first demonstration of the MR signal decay due to diffusion in the internal field (DDIF) for in vivo knee trabecular bone imaging. DDIF contrast was compared with high resolution FLASH, T1, and T2* mapping in healthy volunteers. DDIF
maps showed spatial variation, superimposed on a T1 background, reflecting trabecular structure. DDIF and T2* maps showed correlated contrast near dense trabeculae, but their spatial textures differed, suggesting distinct structural sensitivities
- …