135 research outputs found
Large inverse tunneling magnetoresistance in CoCrFeAl/MgO/CoFe magnetic tunnel junctions
Magnetic tunnel junctions with the layer sequence
CoCrFeAl/MgO/CoFe were fabricated by magnetron sputtering
at room temperature (RT). The samples exhibit a large inverse tunneling
magnetoresistance (TMR) effect of up to -66% at RT. The largest value of -84%
at 20 K reflects a rather weak influence of temperature. The dependence on the
voltage drop shows an unusual behavior with two almost symmetric peaks at
mV with large inverse TMR ratios and small positive values around zero
bias
Structural and magneto-transport characterization of Co_2Cr_xFe_(1-x)Al Heusler alloy films
We investigate the structure and magneto-transport properties of thin films
of the Co_2Cr_xFe_(1-x)Al full-Heusler compound, which is predicted to be a
half-metal by first-principles theoretical calculations. Thin films are
deposited by magnetron sputtering at room temperature on various substrates in
order to tune the growth from polycrystalline on thermally oxidized Si
substrates to highly textured and even epitaxial on MgO(001) substrates,
respectively. Our Heusler films are magnetically very soft and ferromagnetic
with Curie temperatures up to 630 K. The total magnetic moment is reduced
compared to the theoretical bulk value, but still comparable to values reported
for films grown at elevated temperature. Polycrystalline Heusler films combined
with MgO barriers are incorporated into magnetic tunnel junctions and yield 37%
magnetoresistance at room temperature
Channelling study of LaSrCoO films on different substrates
The cobalt oxide system LaCoO and its Sr-doped child compounds have been
intensively studied for decades due to their intriguing magnetic and electronic
properties. Preparing thin LaSrCoO (LSCO) films on different
substrates allows for studies with a new type of perturbation, as the films are
subject to substrate-dependent epitaxial strain. By choosing a proper substrate
for a thin film grow, not only compressing but also tensile strain can be
applied. The consequences for the fundamental physical properties are dramatic:
while compressed films are metallic, as the bulk material, films under tensile
strain become insulating. The goal of this work is to determine the strain
tensor in LSCO films prepared on LaAlO and SrTiO substrates by pulsed
laser deposition using RBS/channelling methods. Apart from the composition and
defect structure of the samples, the depth dependence of the strain tensor, the
cell parameters, and the volume of the unit cell are also determined.
Asymmetric behaviour of the strained cell parameters is found on both
substrates. This asymmetry is rather weak in the case of LSCO film grown on
LaAlO, while stronger on SrTiO substrate. The strain is more effective
at the interface, some relaxation can be observed near to the surface
Trade-offs in managing commercial consumer returns for online apparel retail
Purpose: This paper analyses the application of Lean Six Sigma framework for supporting continuous improvement in logistics services. Both the lean philosophy and the Six Sigma methodology have become two of the most important initiatives for continuous improvement in organizations. The combination of both alternatives - Lean Six Sigma (LSS) - brings significant benefits for companies applying this method and its influence in logistics services can be relevant. Design/methodology/approach: A case study on the logistics services of a large consumer electronics company is performed. In this sector, high quality in logistics services is crucial. Using within-case and cross-case analyses, the paper discusses the implementation of LSS in two internal logistics processes. Findings: The paper identifies important implementation aspects when applying LSS to logistics services, such as continuous improvement structure, strategic analysis, cross-functional teams, and process management. Furthermore, the paper discusses the potential in logistics services of the DMAIC approach and tools like VSM, SIPOC and Process Mapping. Practical implications: The paper analyses two logistics processes where LSS has been applied – a payment process and a request-to-ship process. The analysis of both processes offers relevant information about organizational implementation in a logistics services environment, about process improvement and about the use of LSS tools. Originality/value: Firstly, this paper addresses the gap in literature about LSS and logistics’ activities. Furthermore, the case company, with more than 9.000 employees and distributing its products to more than 100 countries, constitutes a valuable source of information to obtain insights in the implications of implementing LSS in logistics services
Giant positive magnetoresistance in metallic VOx thin films
We report on giant positive magnetoresistance effect observed in VOx thin
films, epitaxially grown on SrTiO3 substrate. The MR effect depends strongly on
temperature and oxygen content and is anisotropic. At low temperatures its
magnitude reaches 70% in a magnetic field of 5 T. Strong electron-electron
interactions in the presence of strong disorder may qualitatively explain the
results. An alternative explanation, related to a possible magnetic
instability, is also discussed.Comment: 4 pages, 5 figures included in the text, references update
Implementation of Whole-Body MRI (MY-RADS) within the OPTIMUM/MUKnine multi-centre clinical trial for patients with myeloma.
BACKGROUND: Whole-body (WB) MRI, which includes diffusion-weighted imaging (DWI) and T1-w Dixon, permits sensitive detection of marrow disease in addition to qualitative and quantitative measurements of disease and response to treatment of bone marrow. We report on the first study to embed standardised WB-MRI within a prospective, multi-centre myeloma clinical trial (IMAGIMM trial, sub-study of OPTIMUM/MUKnine) to explore the use of WB-MRI to detect minimal residual disease after treatment. METHODS: The standardised MY-RADS WB-MRI protocol was set up on a local 1.5Â T scanner. An imaging manual describing the MR protocol, quality assurance/control procedures and data transfer was produced and provided to sites. For non-identical scanners (different vendor or magnet strength), site visits from our physics team were organised to support protocol optimisation. The site qualification process included review of phantom and volunteer data acquired at each site and a teleconference to brief the multidisciplinary team. Image quality of initial patients at each site was assessed. RESULTS: WB-MRI was successfully set up at 12 UK sites involving 3 vendor systems and two field strengths. Four main protocols (1.5Â T Siemens, 3Â T Siemens, 1.5Â T Philips and 3Â T GE scanners) were generated. Scanner limitations (hardware and software) and scanning time constraint required protocol modifications for 4 sites. Nevertheless, shared methodology and imaging protocols enabled other centres to obtain images suitable for qualitative and quantitative analysis. CONCLUSIONS: Standardised WB-MRI protocols can be implemented and supported in prospective multi-centre clinical trials. Trial registration NCT03188172 clinicaltrials.gov; registration date 15th June 2017 https://clinicaltrials.gov/ct2/show/study/NCT03188172
Effect of P to A Mutation of the N-Terminal Residue Adjacent to the Rgd Motif on Rhodostomin: Importance of Dynamics in Integrin Recognition
Rhodostomin (Rho) is an RGD protein that specifically inhibits integrins. We found that Rho mutants with the P48A mutation 4.4–11.5 times more actively inhibited integrin α5β1. Structural analysis showed that they have a similar 3D conformation for the RGD loop. Docking analysis also showed no difference between their interactions with integrin α5β1. However, the backbone dynamics of RGD residues were different. The values of the R2 relaxation parameter for Rho residues R49 and D51 were 39% and 54% higher than those of the P48A mutant, which caused differences in S2, Rex, and τe. The S2 values of the P48A mutant residues R49, G50, and D51 were 29%, 14%, and 28% lower than those of Rho. The Rex values of Rho residues R49 and D51 were 0.91 s−1 and 1.42 s−1; however, no Rex was found for those of the P48A mutant. The τe values of Rho residues R49 and D51 were 9.5 and 5.1 times lower than those of P48A mutant. Mutational study showed that integrin α5β1 prefers its ligands to contain (G/A)RGD but not PRGD sequences for binding. These results demonstrate that the N-terminal proline residue adjacent to the RGD motif affect its function and dynamics, which suggests that the dynamic properties of the RGD motif may be important in Rho's interaction with integrin α5β1
- …