1,030 research outputs found
Study of annoyance due to urban automobile traffic
Continuous traffic noise measurements were carried out over 48 hour periods in front of a hundred buildings in different types of streets in Paris and its suburbs. Physical interpretation of the results provides a noise prediction formula for a traditional type of street. The noise at each point was characterized by a limited number of parameters by means of factor analysis, and their effect on the degree of disturbance by 700 individuals questioned near the measurement stations was studied. It was found that many additional factors affect disturbance besides noise, and that the dispersion of replies for any given noise situation is very wide. A disturbance index is proposed which takes into account the daylight level L(50), the position of rooms in the dwelling exposed to noise, and the individual degrees of satisfaction with the area
Study of annoyance due to urban automobile traffic. Annex 5: Sociological study
The aim, method, description, and results of the study of the influence of traffic noise on the annoyance of persons living near points of measurement are discussed. A facsimile of the questionnaire used in the study is included. The essential themes were: the different dimensions of annoyance; the means of defense against noise; the criteria subjects use to describe the noise; attitudes regarding noise; and the functions of noises
Study of annoyance due to urban automobile traffic. Annex 4: A catalog of the characteristics of noise at different measuring points
The characteristics of urban traffic were studied. Data synthesis of and data specifically for the city of Paris concerning noise due to automobile traffic were examined. Information on noise characteristics at different measuring locations is presented
Indicators for Evaluating the Performance and Quality of Care of Ambulatory Care Nurses
The quality and safety of nursing care vary from one service to another. We have only very limited information on the quality and safety of nursing care in outpatient settings, an expanding area of practice. Our aim in this study was to make available, from the scientific literature, indicators potentially sensitive to nursing that can be used to evaluate the performance of nursing care in outpatient settings and to integrate those indicators into the theoretical framework of Dubois et al. (2013). We conducted a scoping review in three databases (CINAHL, MEDLINE, and EMBASE) and the bibliographies of selected articles. From a total of 116 articles, we selected 22. The results of our study not only enable that framework to be extended to ambulatory nursing care but also enhance it with the addition of five new indicators. Our work offers nurses and managers in ambulatory nursing units indicators potentially sensitive to nursing that can be used to evaluate performance. For researchers, it presents the current state of knowledge on this construct and a framework with theoretical foundations for future research in ambulatory settings. This work opens an unexplored field for further research
A method to localize gamma-ray bursts using POLAR
The hard X-ray polarimeter POLAR aims to measure the linear polarization of
the 50-500 keV photons arriving from the prompt emission of gamma-ray bursts
(GRBs). The position in the sky of the detected GRBs is needed to determine
their level of polarization. We present here a method by which, despite of the
polarimeter incapability of taking images, GRBs can be roughly localized using
POLAR alone. For this purpose scalers are attached to the output of the 25
multi-anode photomultipliers (MAPMs) that collect the light from the POLAR
scintillator target. Each scaler measures how many GRB photons produce at least
one energy deposition above 50 keV in the corresponding MAPM. Simulations show
that the relative outputs of the 25 scalers depend on the GRB position. A
database of very strong GRBs simulated at 10201 positions has been produced.
When a GRB is detected, its location is calculated searching the minimum of the
chi2 obtained in the comparison between the measured scaler pattern and the
database. This GRB localization technique brings enough accuracy so that the
error transmitted to the 100% modulation factor is kept below 10% for GRBs with
fluence Ftot \geq 10^(-5) erg cm^(-2) . The POLAR localization capability will
be useful for those cases where no other instruments are simultaneously
observing the same field of view.Comment: 13 pages, 10 figure
Reversal of the hip fracture secular trend is related to a decrease in the incidence in institution-dwelling elderly women
Summary: In this prospective 10-year study in elderly aged 60years and over, there was a 1.3% per year reduction in the standardized incidence of hip fracture in women but not in men. This decrease was mainly due to changes in the standardized incidence of hip fracture in institution-dwelling women. Introduction: A decrease in age-adjusted hip fracture incidence has been recently demonstrated in some countries. Since a large proportion of hip fractures occur in nursing homes, we analyzed whether this decreasing trend would be more detectable in institution-dwelling elderly compared with community-dwelling elderly. Methods: All hip fracture patients aged 60years and over were identified in a well-defined area. Incidence of hip fracture, age- and sex-adjusted to the 2000 Geneva population, was computed in community- and institution-dwelling elderly. Results: From 1991 to 2000, 1,624 (41%) hip fractures were recorded in institutionalized-dwelling elderly and 2,327 (59%) in community-dwelling elderly. The standardized fracture incidence decreased by 1.3% per year in women (p = 0.039), but remained unchanged in men (+0.5%; p = 0.686). Among institution-dwelling women, hip fracture incidence fell by 1.9% per year (p = 0.044), whereas it remained stable among community-dwelling women (+0.0%, p = 0.978). In men, no significant change in hip fracture incidence occurred among institution- or community-dwelling elderly. Conclusions: The decrease in the standardized hip fracture incidence in institution-dwelling women is responsible for the reversal in secular trend. Future research should include stratification according to the residential status to better identify the causes responsible for the trend in hip fracture incidenc
The potassic sedimentary rocks in Gale Crater, Mars, as seen by ChemCam on board Curiosity
The Mars Science Laboratory rover Curiosity encountered potassium-rich clastic sedimentary rocks at two sites in Gale Crater, the waypoints Cooperstown and Kimberley. These rocks include several distinct meters thick sedimentary outcrops ranging from fine sandstone to conglomerate, interpreted to record an ancient fluvial or fluvio-deltaic depositional system. From ChemCam Laser-Induced Breakdown Spectroscopy (LIBS) chemical analyses, this suite of sedimentary rocks has an overall mean K2O abundance that is more than 5 times higher than that of the average Martian crust. The combined analysis of ChemCam data with stratigraphic and geographic locations reveals that the mean K2O abundance increases upward through the stratigraphic section. Chemical analyses across each unit can be represented as mixtures of several distinct chemical components, i.e., mineral phases, including K-bearing minerals, mafic silicates, Fe-oxides, and Fe-hydroxide/oxyhydroxides. Possible K-bearing minerals include alkali feldspar (including anorthoclase and sanidine) and K-bearing phyllosilicate such as illite. Mixtures of different source rocks, including a potassium-rich rock located on the rim and walls of Gale Crater, are the likely origin of observed chemical variations within each unit. Physical sorting may have also played a role in the enrichment in K in the Kimberley formation. The occurrence of these potassic sedimentary rocks provides additional evidence for the chemical diversity of the crust exposed at Gale Crater
POLAR, an instrument to measure GRB polarization. Design and laboratory tests.
International audienceReliable polarization measurements of photons from Gamma Ray Bursts (GRB) would make the understanding of the GRB phenomenon progress enormously. POLAR is a concept for an instrument that would enable such a measurement. We report about performances predicted by of Monte-Carlo and on laboratory tests to validate some critical aspects of the desig
POLAR: a space borne GRB polarimeter
International audienceThe direction and the level of polarization of high energy photons emitted by astrophysics sources are valuable observables for the understanding of the corresponding emission mechanisms, source geometry and strength of magnetic fields at work. POLAR is a novel compact space-borne detector conceived for a precise measurement of hard X-ray polarization and optimized for the detection of Gamma-Ray Burst (GRB) photons in the energy range 50-500 keV. In POLAR, the GRB photons undergo Compton scattering in a target made out of 1600 plastic scintillator bars. The azimuthal distribution of the scattered photons inside the target provides the information on the GRB polarization. The target is divided into 5x5 units, each one consisting of 8x8 scintillator bars optically coupled with a multi-anode photomultiplier. POLAR, thanks to its large modulation factor (mu_100=40%), its large effective area (Aeff = 250 cm2), and its large field of view ( 1/3 of the sky) will be able to determine the degree and angle of polarization of a strong GRB with a minimum detectable polarization of less than 10% (3sigma). In this communication the present design and status of the POLAR project is presented. Expected results through deep Monte Carlo simulation studies as well as the recent results of laboratory measurements are detailed
Water Abundance of Dunes in Gale Crater, Mars From Active Neutron Experiments and Implications for Amorphous Phases
We report the water abundance of Bagnold Dune sand in Gale crater, Mars by analyzing active neutron experiments using the Dynamic Albedo of Neutrons instrument. We report a bulk water‐equivalent‐hydrogen abundance of 0.68 ± 0.15 wt%, which is similar to measurements several kilometers away and from those taken of the dune surface. Thus, the dune is likely dehydrated throughout. Furthermore, we use geochemical constraints, including bulk water content, to develop compositional models of the amorphous fraction for which little information is known. We find the amorphous fraction contains ∼26‐ to 64‐wt% basaltic glass and up to ∼24‐wt% rhyolitic glass, suggesting at least one volcanic source for the dune material. We also find a range of hydrated phases may be present in appreciable abundances, either from the incorporation of eroded aqueously altered sediments or the direct alteration of the dune sand
- …
