67 research outputs found

    Focusing narrowly or broadly attention when judging categorical and coordinate spatial relations: A MEG study

    Get PDF
    We measured activity in the dorsal system of the human cortex with magnetoencephalography (MEG) during a matching-to-sample plus cueing paradigm, where participants judged the occurrence of changes in either categorical or coordinate spatial relations (e.g., exchanges of left versus right positions or changes in the relative distances) between images of pairs of animals. The attention window was primed in each trial to be either small or large by using cues that immediately preceded the matching image. In this manner, we could assess the modulatory effects of the scope of attention on the activity of the dorsal system of the human cortex during spatial relations processing. The MEG measurements revealed that large spatial cues yielded greater activations and longer peak latencies in the right inferior parietal lobe for coordinate trials, whereas small cues yielded greater activations and longer peak latencies in the left inferior parietal lobe for categorical trials. The activity in the superior parietal lobe, middle frontal gyrus, and visual cortex, was also modulated by the size of the spatial cues and by the type of spatial relation change. The present results support the theory that the lateralization of each kind of spatial processing hinges on differences in the sizes of regions of space attended to by the two hemispheres. In addition, the present findings are inconsistent with the idea of a right-hemispheric dominance for all kinds of challenging spatial tasks, since response times and accuracy rates showed that the categorical spatial relation task was more difficult than the coordinate task and the cortical activations were overall greater in the left hemisphere than in the right hemisphere

    Cortical Network Topology in Prodromal and Mild Dementia Due to Alzheimer\u2019s Disease: Graph Theory Applied to Resting State EEG

    Get PDF
    Graph theory analysis on resting state electroencephalographic rhythms disclosed topological properties of cerebral network. In Alzheimer\u2019s disease (AD) patients, this approach showed mixed results. Granger causality matrices were used as input to the graph theory allowing to estimate the strength and the direction of information transfer between electrode pairs. The number of edges (degree), the number of inward edges (in-degree), of outgoing edges (out-degree) were statistically compared among healthy controls, patients with mild cognitive impairment due to AD (AD-MCI) and AD patients with mild dementia (ADD) to evaluate if degree abnormality could involve low and/or high degree vertices, the so called hubs, in both prodromal and over dementia stage. Clustering coefficient and local efficiency were evaluated as measures of network segregation, path length and global efficiency as measures of integration, the assortativity coefficient as a measure of resilience. Degree, in-degree and out-degree values were lower in AD-MCI and ADD than the control group for non-hubs and hubs vertices. The number of edges was preserved for frontal electrodes, where patients\u2019 groups showed an additional hub in F3. Clustering coefficient was lower in ADD compared with AD-MCI in the right occipital electrode, and it was positively correlated with mini mental state examination. Local and global efficiency values were lower in patients\u2019 than control groups. Our results show that the topology of the network is altered in AD patients also in its prodromal stage, begins with the reduction of the number of edges and the loss of the local and global efficiency

    Autoscopic phenomena: case report and review of literature

    Get PDF
    BACKGROUND: Autoscopic phenomena are psychic illusory visual experiences consisting of the perception of the image of one's own body or face within space, either from an internal point of view, as in a mirror or from an external point of view. Descriptions based on phenomenological criteria distinguish six types of autoscopic experiences: autoscopic hallucination, he-autoscopy or heautoscopic proper, feeling of a presence, out of body experience, negative and inner forms of autoscopy. METHODS AND RESULTS: We report a case of a patient with he-autoscopic seizures. EEG recordings during the autoscopic experience showed a right parietal epileptic focus. This finding confirms the involvement of the temporo-parietal junction in the abnormal body perception during autoscopic phenomena. We discuss and review previous literature on the topic, as different localization of cortical areas are reported suggesting that out of body experience is generated in the right hemisphere while he-autoscopy involves left hemisphere structures

    A Machine Learning-Based Holistic Approach to Predict the Clinical Course of Patients within the Alzheimer’s Disease Spectrum

    Get PDF
    Background: Alzheimer’s disease (AD) is a neurodegenerative condition driven by multifactorial etiology. Mild cognitive impairment (MCI) is a transitional condition between healthy aging and dementia. No reliable biomarkers are available to predict the conversion from MCI to AD. Objective: To evaluate the use of machine learning (ML) on a wealth of data offered by the Alzheimer’s Disease Neuroimaging Initiative (ADNI) and Alzheimer’s Disease Metabolomics Consortium (ADMC) database in the prediction of the MCI to AD conversion. Methods: We implemented an ML-based Random Forest (RF) algorithm to predict conversion from MCI to AD. Data related to the study population (587 MCI subjects) were analyzed by RF as separate or combined features and assessed for classification power. Four classes of variables were considered: neuropsychological test scores, AD-related cerebrospinal fluid (CSF) biomarkers, peripheral biomarkers, and structural magnetic resonance imaging (MRI) variables. Results: The ML-based algorithm exhibited 86% accuracy in predicting the AD conversion of MCI subjects. When assessing the features that helped the most, neuropsychological test scores, MRI data, and CSF biomarkers were the most relevant in the MCI to AD prediction. Peripheral parameters were effective when employed in association with neuropsychological test scores. Age and sex differences modulated the prediction accuracy. AD conversion was more effectively predicted in females and younger subjects. Conclusion: Our findings support the notion that AD-related neurodegenerative processes result from the concerted activity of multiple pathological mechanisms and factors that act inside and outside the brain and are dynamically affected by age and sex

    Functional cortical source connectivity of resting state electroencephalographic alpha rhythms shows similar abnormalities in patients with mild cognitive impairment due to Alzheimer's and Parkinson's diseases

    Get PDF
    Objective: This study tested the hypothesis that markers of functional cortical source connectivity of resting state eyes-closed electroencephalographic (rsEEG) rhythms may be abnormal in subjects with mild cognitive impairment due to Alzheimer's (ADMCI) and Parkinson's (PDMCI) diseases compared to healthy elderly subjects (Nold). Methods: rsEEG data had been collected in ADMCI, PDMCI, and Nold subjects (N = 75 for any group). eLORETA freeware estimated functional lagged linear connectivity (LLC) from rsEEG cortical sources. Area under receiver operating characteristic (AUROC) curve indexed the accuracy in the classification of Nold and MCI individuals. Results: Posterior interhemispheric and widespread intrahemispheric alpha LLC solutions were abnormally lower in both MCI groups compared to the Nold group. At the individual level, AUROC curves of LLC solutions in posterior alpha sources exhibited moderate accuracies (0.70-0.72) in the discrimination of Nold vs. ADMCI-PDMCI individuals. No differences in the LLC solutions were found between the two MCI groups. Conclusions: These findings unveil similar abnormalities in functional cortical connectivity estimated in widespread alpha sources in ADMCI and PDMCI. This was true at both group and individual levels. Significance: The similar abnormality of alpha source connectivity in ADMCI and PDMCI subjects might reflect common cholinergic impairment. (C) 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved

    Effects of Transcranial Direct Current Stimulation on Episodic Memory Related to Emotional Visual Stimuli

    Get PDF
    The present study investigated emotional memory following bilateral transcranial electrical stimulation (direct current of 1 mA, for 20 minutes) over fronto-temporal cortical areas of healthy participants during the encoding of images that differed in affective arousal and valence. The main result was a significant interaction between the side of anodal stimulation and image emotional valence. Specifically, right anodal/left cathodal stimulation selectively facilitated the recall of pleasant images with respect to both unpleasant and neutral images whereas left anodal/right cathodal stimulation selectively facilitated the recall of unpleasant images with respect to both pleasant and neutral images. From a theoretical perspective, this double dissociation between the side of anodal stimulation and the advantage in the memory performance for a specific type of stimulus depending on its pleasantness supported the specific-valence hypothesis of emotional processes, which assumes a specialization of the right hemisphere in processing unpleasant stimuli and a specialization of the left hemisphere in processing pleasant stimuli. From a methodological point of view, first we found tDCS effects strictly dependent on the stimulus category, and second a pattern of results in line with an interfering and inhibitory account of anodal stimulation on memory performance. These findings need to be carefully considered in applied contexts, such as the rehabilitation of altered emotional processing or eye-witness memory, and deserve to be further investigated in order to understand their underlying mechanisms of action

    Improving MEG source localizations: an automated method for complete artifact removal based on independent component analysis

    No full text
    The major limitation for the acquisition of high-quality magnetoencephalography (MEG) recordings is the presence of disturbances of physiological and technical origins: eye movements, cardiac signals, muscular contractions, and environmental noise are serious problems for MEG signal analysis. In the last years, multi-channel MEG systems have undergone rapid technological developments in terms of noise reduction, and many processing methods have been proposed for artifact rejection. Independent component analysis (ICA) has already shown to be an effective and generally applicable technique for concurrently removing artifacts and noise from the MEG recordings. However, no standardized automated system based on ICA has become available so far, because of the intrinsic difficulty in the reliable categorization of the source signals obtained with this technique. In this work, approximate entropy (ApEn), a measure of data regularity, is successfully used for the classification of the signals produced by ICA, allowing for an automated artifact rejection. The proposed method has been tested using MEG data sets collected during somatosensory, auditory and visual stimulation. It was demonstrated to be effective in attenuating both biological artifacts and environmental noise, in order to reconstruct clear signals that can be used for improving brain source localizations.status: publishe

    A Randomized Pilot Clinical and Microbiological Study Comparing Laser Microtextured Implants with and without Platform Switching

    No full text
    Minimising marginal bone loss around dental implants is of paramount importance. The success of methods such as platform switching (PS) and laser-micro-texturing (LM) are well documented. Whether or not a combination of these designs will further improve outcomes has not been studied previously. Hence, this prospective, randomized controlled single-centre pilot study compared the clinical and microbiological outcomes of implants with both PS and LM (test) to implants with only LM (control). A test and control implant were placed in thirteen patients totalling 26 implants. The primary investigated outcome was marginal bone level (MBL); secondary outcomes were peri-implant probing depths (PPD), bleeding on probing (BOP) and marginal tissue height (MTH). Additionally, the presence of five putative periodontal pathogens were assessed using real-time polymerized chain reaction. At 12 months the overall implant survival rate was 95.8%. MBL change was not found to be different between test and control at any time points, but a significant change was detected within the test implants at 6 months compared to baseline (p = 0.006). No differences were found in the secondary outcomes. Average PPD at 12 months was 2.68 ± 0.73 mm and 2.30 ± 0.46 mm and average change in MTH was 0.05 ± 0.72 mm and −0.24 ± 0.59 mm at tests and controls. No differences were reported in BOP frequency. Total periodontal pathogens count revealed no significant difference among control, test implants and adjacent tooth sites. Within the limitations of this study, it can be concluded that the addition of PS to LM implants does not significantly alter either short-term clinical outcomes or the vulnerability to pathogenic microflora colonization

    Giant early components of somatosensory evoked potentials to tibial nerve stimulation in cortical myoclonus

    Get PDF
    Enlarged cortical components of somatosensory evoked potentials (giant SEPs) recorded by electroencephalography (EEG) and abnormal somatosensory evoked magnetic fields (SEFs) recorded by magnetoencephalography (MEG) are observed in the majority of patients with cortical myoclonus (CM). Studies on simultaneous recordings of SEPs and SEFs showed that generator mechanism of giant SEPs involves both primary sensory and motor cortices. However the generator sources of giant SEPs have not been fully understood as only one report describes clearly giant SEPs following lower limb stimulation. In our study we performed a combined EEG-MEG recording on responses elicited by electric median and tibial nerve stimulation in a patient who developed consequently to methyl bromide intoxication CM with giant SEPs to median and tibial nerve stimuli. SEPs wave shapes were identified on the basis of polarity-latency components (e.g. P15-N20-P25) as defined by earlier studies and guidelines. At EEG recording, the SEP giant component did not appear in the latency range of the first cortical component for median nerve SEP (N20), but appeared instead in the range of the P37 tibial nerve SEP, which is currently identified as the first cortical component elicited by tibial nerve stimuli. Our MEG and EEG SEPs recordings also showed that components in the latency range of P37 were preceded by other cortical components. These findings suggest that lower limb P37 does not correspond to upper limb N20. MEG results confirmed that giant SEFs are the second component from both tibial (N43m-P43m) and median (N27m-P27m) nerve stimulation. MEG dipolar sources of these giant components were located in the primary sensory and motor area
    corecore