1,980 research outputs found

    Differential Imaging with a Multicolor Detector Assembly: A New ExoPlanet Finder Concept

    Full text link
    Simultaneous spectral differential imaging is a high contrast technique by which subtraction of simultaneous images reduces noise from atmospheric speckles and optical aberrations. Small non-common wave front errors between channels can seriously degrade its performance. We present a new concept, a multicolor detector assembly (MCDA), which can eliminate this problem. The device consists of an infrared detector and a microlens array onto the flat side of which a checkerboard pattern of narrow-band micro-filters is deposited, each micro-filter coinciding with a microlens. Practical considerations for successful implementation of the technique are mentioned. Numerical simulations predict a noise attenuation of 10^-3 at 0.5" for a 10^5 seconds integration on a mH=5 star of Strehl ratio 0.9 taken with an 8-m telescope. This reaches a contrast of 10^-7 at an angular distance of 0.5" from the center of the star image.Comment: 13 pages, 5 figures, accepted APJ

    Effects of Quasi-Static Aberrations in Faint Companion Searches

    Get PDF
    We present the first results obtained at CFHT with the TRIDENT infrared camera, dedicated to the detection of faint companions close to bright nearby stars. The camera's main feature is the acquisition of three simultaneous images in three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, that enables a precise subtraction of the primary star PSF while keeping the companion signal. The main limitation is non-common path aberrations between the three optical paths that slightly decorrelate the PSFs. Two types of PSF calibrations are combined with the differential simultaneous imaging technique to further attenuate the PSF: reference star subtraction and instrument rotation to smooth aberrations. It is shown that a faint companion with a DeltaH of 10 magnitudes would be detected at 0.5 arcsec from the primary.Comment: 12 pages, 10 figures, to appear in Astronomy with High Contrast Imaging, EAS Publications Serie

    Airboat Use and Disturbance of Floating Mat Fen Wetlands in Interior Alaska, U.S.A.

    Get PDF
    The use of airboats is expanding in Alaska, particularly in the interior. This study describes the nature, magnitude, and distribution of disturbance caused by airboat trails over floating mat fen wetlands in the Tanana Flats near Fairbanks, Alaska. Airphoto interpretation showed over 300 km of airboat trails by 1995, with a 15% expansion of the trail system since 1989. Field sampling was done at 30 trail and adjacent control sites along this trail system to assess changes in hydrology, soils, and vegetation. Water velocities in the trails at two-thirds of the sites were at least an order of magnitude greater than velocities of less than 1.5 cm/sec in the control areas. On average, 30 cm of the 0.5-0.75 m thick floating mat has been removed or eroded by airboat traffic at the sampling locations. Nearly all emergent floating mat vegetation has been destroyed (5% cover remaining on average) so that the trails resemble a highly visible open water stream channel 2-3 m wide through the floating mats. Although the recovery and regrowth potential of floating mats in trails is high, recovery is unlikely in trails with continuing use.En Alaska, l'utilisation des hydroglisseurs est à la hausse, surtout à l'intérieur des terres. Cette étude décrit la nature, l'amplitude et la distribution des perturbations causées par le sillage des hydroglisseurs sur les zones humides de vasières à mattes flottantes situées dans les plaines marécageuses de Tanana près de Fairbanks (en Alaska). L'interprétation de photos a montré que, en 1995, les sillages d'hydroglisseurs s'étendaient sur plus de 300 km, ce qui correspond à une augmentation de 15 p. cent du réseau depuis 1989. On a procédé à un échantillonnage sur le terrain à 30 emplacements de sillages et aires témoins adjacentes le long du réseau en vue d'évaluer les changements dans l'hydrologie, les sols et la végétation. Dans deux tiers des emplacements, la vitesse de l'eau dans les sillages était d'au moins un ordre de grandeur supérieure aux vitesses de moins de 1,5 cm/sec dans les zones témoins. Aux endroits d'échantillonnage, 30 cm en moyenne de la matte flottante épaisse de 0,5 à 0,75 m a été enlevée ou érodée par la circulation de l'hydroglisseur. Presque toute la végétation de la matte flottante émergée a été détruite (il reste en moyenne 5 p. cent du couvert) de sorte que les sillages sont très visibles et forment un chenal d'eau ouverte de 2 à 3 m de large à travers les mattes flottantes. Bien que le potentiel de recouvrement et de repousse des mattes flottantes dans les sillages soit élevé, il est peu probable que ce recouvrement ait lieu dans les sillages qui sont utilisés de façon continue

    Tree species, crown cover, and age as determinants of the vertical distribution of airborne LiDAR returns

    Full text link
    Light detection and ranging (LiDAR) provides information on the vertical structure of forest stands enabling detailed and extensive ecosystem study. The vertical structure is often summarized by scalar features and data-reduction techniques that limit the interpretation of results. Instead, we quantified the influence of three variables, species, crown cover, and age, on the vertical distribution of airborne LiDAR returns from forest stands. We studied 5,428 regular, even-aged stands in Quebec (Canada) with five dominant species: balsam fir (Abies balsamea (L.) Mill.), paper birch (Betula papyrifera Marsh), black spruce (Picea mariana (Mill.) BSP), white spruce (Picea glauca Moench) and aspen (Populus tremuloides Michx.). We modeled the vertical distribution against the three variables using a functional general linear model and a novel nonparametric graphical test of significance. Results indicate that LiDAR returns from aspen stands had the most uniform vertical distribution. Balsam fir and white birch distributions were similar and centered at around 50% of the stand height, and black spruce and white spruce distributions were skewed to below 30% of stand height (p<0.001). Increased crown cover concentrated the distributions around 50% of stand height. Increasing age gradually shifted the distributions higher in the stand for stands younger than 70-years, before plateauing and slowly declining at 90-120 years. Results suggest that the vertical distributions of LiDAR returns depend on the three variables studied

    Benchmarking quantum control methods on a 12-qubit system

    Full text link
    In this letter, we present an experimental benchmark of operational control methods in quantum information processors extended up to 12 qubits. We implement universal control of this large Hilbert space using two complementary approaches and discuss their accuracy and scalability. Despite decoherence, we were able to reach a 12-coherence state (or 12-qubits pseudo-pure cat state), and decode it into an 11 qubit plus one qutrit labeled observable pseudo-pure state using liquid state nuclear magnetic resonance quantum information processors.Comment: 11 pages, 4 figures, to be published in PR

    TRIDENT: an Infrared Differential Imaging Camera Optimized for the Detection of Methanated Substellar Companions

    Full text link
    A near-infrared camera in use at the Canada-France-Hawaii Telescope (CFHT) and at the 1.6-m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths across the methane absorption bandhead at 1.6 microns, enabling, in theory, an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features fast data acquisition, yielding high observing efficiency on bright stars. The performance of the instrument is described, and it is illustrated by laboratory tests and CFHT observations of the nearby stars GL526, Ups And and Chi And. TRIDENT can detect (6 sigma) a methanated companion with delta H = 9.5 at 0.5" separation from the star in one hour of observing time. Non-common path aberrations and amplitude modulation differences between the three optical paths are likely to be the limiting factors preventing further PSF attenuation. Instrument rotation and reference star subtraction improve the detection limit by a factor of 2 and 4 respectively. A PSF noise attenuation model is presented to estimate the non-common path wavefront difference effect on PSF subtraction performance.Comment: 41 pages, 16 figures, accepted for publication in PAS

    UK science press officers, professional vision and the generation of expectations

    Get PDF
    Science press officers can play an integral role in helping promote expectations and hype about biomedical research. Using this as a starting point, this article draws on interviews with 10 UK-based science press officers, which explored how they view their role as science reporters and as generators of expectations. Using Goodwin’s notion of ‘professional vision’, we argue that science press officers have a specific professional vision that shapes how they produce biomedical press releases, engage in promotion of biomedical research and make sense of hype. We discuss how these insights can contribute to the sociology of expectations, as well as inform responsible science communication.This project was funded by the Wellcome Trust (Wellcome Trust Biomedical Strategic Award 086034)

    TRIDENT: an infrared camera optimized for the detection of methanated substellar companions around nearby stars

    Get PDF
    A near-infrared (0.85-2.5 microns) camera in use at the Canada-France-Hawaii Telescope and at the 1.6m telescope of the Observatoire du Mont-Megantic is described. The camera is based on a Hawaii-1 1024x1024 HgCdTe array detector. Its main feature is to acquire three simultaneous images at three wavelengths (simultaneous differential imaging) across the methane absorption bandhead at 1.6 micron, enabling an accurate subtraction of the stellar point spread function (PSF) and the detection of faint close methanated companions. The instrument has no coronagraph and features a fast (1 MHz) data acquisition system without reset anomaly, yielding high observing efficiencies on bright stars. The performance of the instrument is described, and it is illustrated by CFHT images of the nearby star Ups And. TRIDENT can detect (3 sigma) a methanated companion with DeltaH=10 at 0.5 arcsec from the star in one hour of observing time. Non-common path aberrations between the three optical paths are the limiting factors preventing further PSF attenuation. Reference star subtraction and instrument rotation improve the detection limit by one order of magnitude.Comment: 8 pages, 6 figures, to appear in SPIE 486

    Optimization of Apodized Pupil Lyot Coronagraph for ELTs

    Full text link
    We study the optimization of the Apodized Pupil Lyot Coronagraph (APLC) in the context of exoplanet imaging with ground-based telescopes. The APLC combines an apodization in the pupil plane with a small Lyot mask in the focal plane of the instrument. It has been intensively studied in the literature from a theoretical point of view, and prototypes are currently being manufactured for several projects. This analysis is focused on the case of Extremely Large Telescopes, but is also relevant for other telescope designs. We define a criterion to optimize the APLC with respect to telescope characteristics like central obscuration, pupil shape, low order segment aberrations and reflectivity as function of the APLC apodizer function and mask diameter. Specifically, the method was applied to two possible designs of the future European-Extremely Large Telescope (E-ELT). Optimum configurations of the APLC were derived for different telescope characteristics. We show that the optimum configuration is a stronger function of central obscuration size than of other telescope parameters. We also show that APLC performance is quite insensitive to the central obscuration ratio when the APLC is operated in its optimum configuration, and demonstrate that APLC optimization based on throughput alone is not appropriate.Comment: 9 pages, 17 figures, accepted for publication in Astronomy & Astrophysic
    corecore