1,793 research outputs found

    Time-resolved Kerr microscopy of coupled transverse domain walls in a pair of curved nanowires

    Get PDF
    This is the final version of the article. Available from the American Institute of Physics via the DOI in this record.Time-resolved scanning Kerr microscopy has been used to directly observe magnetostatically coupled transverse domain walls (TDWs) in a pair of closely spaced, curved nanowires (NWs). Kerr images of the precessional response of the magnetic domain to either side of the TDW revealed the TDW as a minimum in the Kerr signal in the region of closest NW separation. When the TDWs were ejected from the NW pair, the minimum in the Kerr signal was no longer observed. By imaging this transition, the static de-coupling field was estimated to be in the range from 38 to 48 Oe in good agreement with a simple micromagnetic model. This work provides a novel technique by which DC and microwave assisted decoupling fields of TDWs may be explored in NW pairs of different width, separation, and curvature.This work was supported by the EU Grant Master No. NMP-FP7-212257, the UK EPSRC Grant Ref. EP/I038470/1, and partially supported by the EU FP7 Project 3SPIN No. 247368, and the Marie Curie IOF Project No. 299376

    Piloting a parent and patient decision aid to support clinical trial decision making in childhood cancer

    Full text link
    Objective: Families of a child with cancer can find the decision to enrol in a clinical trial challenging and often misunderstand key concepts that underpin trials. We pilot tested “Delta,” an online and booklet decision aid for parents with a child with cancer, and adolescents with cancer, deciding whether or not to enrol in a clinical trial. Methods: We developed Delta in accordance with the International Patient Decision Aid Standards. We conducted a pre-post pilot with parents with a child, and adolescents, who had enrolled in a paediatric phase III clinical trial for newly diagnosed acute lymphoblastic leukaemia. Parents (n = 37) and adolescents (n = 3) completed a questionnaire before and after using Delta (either the website or booklet, based on their preference). Results: Twenty-three parents (62.2%) and three adolescents (100%) reviewed the Delta website. Parents rated Delta as highly acceptable in regard to being clearly presented, informative, easy to read, useful, visually appealing, and easy to use. All participants reported that they would recommend Delta to others and that it would have been useful when making their decision. Parents' subjective (Mdiff=10.8, SDdiff = 15.69, P <.001) and objective (OR = 2.25, 95% CI, 1.66-3.04; P <.001) clinical trial knowledge increased significantly after reviewing Delta. Conclusions: To our knowledge, Delta is the first reported decision aid, available online and as a booklet, for parents and adolescents deciding whether or not to enrol in a paediatric oncology clinical trial. Our study suggests that Delta is acceptable, feasible, and potentially useful

    Hookworm Infection and Environmental Factors in Mbeya Region, Tanzania: A Cross-sectional, Population-based study.

    Get PDF
    Hookworm disease is one of the most common infections and cause of a high disease burden in the tropics and subtropics. Remotely sensed ecological data and model-based geostatistics have been used recently to identify areas in need for hookworm control. Cross-sectional interview data and stool samples from 6,375 participants from nine different sites in Mbeya region, south-western Tanzania, were collected as part of a cohort study. Hookworm infection was assessed by microscopy of duplicate Kato-Katz thick smears from one stool sample from each participant. A geographic information system was used to obtain remotely sensed environmental data such as land surface temperature (LST), vegetation cover, rainfall, and elevation, and combine them with hookworm infection data and with socio-demographic and behavioral data. Uni- and multivariable logistic regression was performed on sites separately and on the pooled dataset. Univariable analyses yielded significant associations for all ecological variables. Five ecological variables stayed significant in the final multivariable model: population density (odds ratio (OR) = 0.68; 95% confidence interval (CI) = 0.63-0.73), mean annual vegetation density (OR = 0.11; 95% CI = 0.06-0.18), mean annual LST during the day (OR = 0.81; 95% CI = 0.75-0.88), mean annual LST during the night (OR = 1.54; 95% CI = 1.44-1.64), and latrine coverage in household surroundings (OR = 1.02; 95% CI = 1.01-1.04). Interaction terms revealed substantial differences in associations of hookworm infection with population density, mean annual enhanced vegetation index, and latrine coverage between the two sites with the highest prevalence of infection. This study supports previous findings that remotely sensed data such as vegetation indices, LST, and elevation are strongly associated with hookworm prevalence. However, the results indicate that the influence of environmental conditions can differ substantially within a relatively small geographic area. The use of large-scale associations as a predictive tool on smaller scales is therefore problematic and should be handled with care

    Chemical models important in understanding the ways in which chromate can damage DNA.

    Get PDF
    Chromate is an established human carcinogen. There have been many studies of the reactivity of chromate aimed at improving understanding of chromate toxicity. In the present paper a number of conclusions of these studies are reviewed and considered in the light of new results obtained in our laboratories. A number of hypotheses are considered; it is concluded, however, that it is impossible to reconcile the generation of strand breaks by chromate during its reduction by glutathione with any simple mechanism involving the generation of DNA lesions by free hydroxyl radicals. Kinetic, spin-trapping, and competition kinetic studies, based on a strand-breaking assay, are reported in support of this conclusion

    In Vivo Measurement of Hippocampal GABAA/cBZR Density with [18F]-Flumazenil PET for the Study of Disease Progression in an Animal Model of Temporal Lobe Epilepsy

    Get PDF
    PURPOSE: Imbalance of inhibitory GABAergic neurotransmission has been proposed to play a role in the pathogenesis of temporal lobe epilepsy (TLE). This study aimed to investigate whether [(18)F]-flumazenil ([(18)F]-FMZ) PET could be used to non-invasively characterise GABA(A)/central benzodiazepine receptor (GABA(A)/cBZR) density and affinity in vivo in the post-kainic acid status epilepticus (SE) model of TLE. METHODS: Dynamic [(18)F]-FMZ -PET scans using a multi-injection protocol were acquired in four male wistar rats for validation of the partial saturation model (PSM). SE was induced in eight male Wistar rats (10 weeks of age) by i.p. injection of kainic acid (7.5–25 mg/kg), while control rats (n = 7) received saline injections. Five weeks post-SE, an anatomic MRI scan was acquired and the following week an [(18)F]-FMZ PET scan (3.6–4.6 nmol). The PET data was co-registered to the MRI and regions of interest drawn on the MRI for selected structures. A PSM was used to derive receptor density and apparent affinity from the [(18)F]-FMZ PET data. KEY FINDINGS: The PSM was found to adequately model [(18)F]-FMZ binding in vivo. There was a significant decrease in hippocampal receptor density in the SE group (p<0.01), accompanied by an increase in apparent affinity (p<0.05) compared to controls. No change in cortical receptor binding was observed. Hippocampal volume reduction and cell loss was only seen in a subset of animals. Histological assessment of hippocampal cell loss was significantly correlated with hippocampal volume measured by MRI (p<0.05), but did not correlate with [(18)F]-FMZ binding. SIGNIFICANCE: Alterations to hippocampal GABA(A)/cBZR density and affinity in the post-kainic acid SE model of TLE are detectable in vivo with [(18)F]-FMZ PET and a PSM. These changes are independent from hippocampal cell and volume loss. [(18)F]-FMZ PET is useful for investigating the role that changes GABA(A)/cBZR density and binding affinity play in the pathogenesis of TLE

    GaInNAs-based Hellish-vertical cavity semiconductor optical amplifier for 1.3 μm operation

    Get PDF
    Hot electron light emission and lasing in semiconductor heterostructure (Hellish) devices are surface emitters the operation of which is based on the longitudinal injection of electrons and holes in the active region. These devices can be designed to be used as vertical cavity surface emitting laser or, as in this study, as a vertical cavity semiconductor optical amplifier (VCSOA). This study investigates the prospects for a Hellish VCSOA based on GaInNAs/GaAs material for operation in the 1.3-μm wavelength range. Hellish VCSOAs have increased functionality, and use undoped distributed Bragg reflectors; and this coupled with direct injection into the active region is expected to yield improvements in the gain and bandwidth. The design of the Hellish VCSOA is based on the transfer matrix method and the optical field distribution within the structure, where the determination of the position of quantum wells is crucial. A full assessment of Hellish VCSOAs has been performed in a device with eleven layers of Ga0.35In0.65N0.02As0.08/GaAs quantum wells (QWs) in the active region. It was characterised through I-V, L-V and by spectral photoluminescence, electroluminescence and electro-photoluminescence as a function of temperature and applied bias. Cavity resonance and gain peak curves have been calculated at different temperatures. Good agreement between experimental and theoretical results has been obtained

    Validation protocols for blood pressure measuring devices: the impact of the European Society of Hypertension International Protocol and the development of a Universal Standard

    Get PDF
    In the last three decades protocols for the validation of blood pressure measuring devices have been developed by the US Association for the Advancement of Medical Instrumentation, the British Hypertension Society, the German Hypertension League, the European Society of Hypertension Working Group on blood pressure Monitoring and the International Organization for Standardization. The European Society of Hypertension International Protocol required much smaller sample size than the other protocols, aiming to reduce the time, resources and cost of validation studies and thereby increase the number of validated devices. Given its specifications, the European Society of Hypertension International Protocol was adequate for ‘high- and low-accuracy’ devices, yet assessment of ‘moderate accuracy’ devices had high uncertainty with resultant high rate of device failure. Thus, devices validated using the European Society of Hypertension International Protocol should be considered to be as accurate as those validated with the previous Association for the Advancement of Medical Instrumentation or British Hypertension Society protocols. However, the European Society of Hypertension International Protocol did not allow subgroup evaluation (arm sizes, special populations, etc). The mission of the European Society of Hypertension International Protocol to promote the concept of validation has been well achieved, as almost double studies have been published using it than all the other protocols together. However, the maintenance of different validation protocols is confusing and therefore experts from the Association for the Advancement of Medical Instrumentation, European Society of Hypertension International Protocol and International Organization for Standardization have now developed the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) as the recommended 21st-century procedure for worldwide application. The European Society of Hypertension Working Group has published a practical guide for using the Universal Standard. It is in the interests of all scientific bodies to propagate the Universal Standard and ensure its wide implementation

    Efficient Genotyping of KRAS Mutant Non-Small Cell Lung Cancer Using a Multiplexed Droplet Digital PCR Approach

    Get PDF
    © 2015 Pender et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Droplet digital PCR (ddPCR) can be used to detect low frequency mutations in oncogenedriven lung cancer. The range of KRAS point mutations observed in NSCLC necessitates a multiplex approach to efficient mutation detection in circulating DNA. Here we report the design and optimisation of three discriminatory ddPCR multiplex assays investigating nine different KRAS mutations using PrimePCRddPCRMutation Assays and the Bio-Rad QX100 system. Together these mutations account for 95% of the nucleotide changes found in KRAS in human cancer. Multiplex reactions were optimised on genomic DNA extracted from KRAS mutant cell lines and tested on DNA extracted from fixed tumour tissue from a cohort of lung cancer patients without prior knowledge of the specific KRAS genotype. The multiplex ddPCR assays had a limit of detection of better than 1 mutant KRAS molecule in 2,000 wild-type KRAS molecules, which compared favourably with a limit of detection of 1 in 50 for next generation sequencing and 1 in 10 for Sanger sequencing. Multiplex ddPCR assays thus provide a highly efficient methodology to identify KRAS mutations in lung adenocarcinoma
    corecore