159 research outputs found

    GATE simulation for medical physics with genius Web portal

    Get PDF
    présenté par C. ThiamPCSV team of the LPC laboratory in Clermont-Ferrand is involved in the deployment of biomedical applications on the grid architecture. One of these applications deals with the deployment of GATE (Geant4 Application for Tomographic Emission) for medical physics application. The aim of the developments actually performed is to enable an application of the GATE platform in clinical routine. However, this perspective is only possible if the computing time and user time are highly reduced. The new grid architecture, developed within the framework of the European project Enabling Grid for E-sciencE (EGEE) is there to answer this requirement. The use of the grid resources must be transparent easy and rapid for the medical physicists. For this perpose, we adapted the GENIUS web portal in order to facilitate the GATE simulations planning on the grid. We will present a demonstration of the GENIUS portal which integrates all the functionalities of EGEE: to create, to submit and manage GATE jobs on the grid architecture. Our GATE activities for dosimetry application entered in to direct phase of evaluation by the cancer treatment center of Clermont Ferrand (Centre Jean perrin).A work station is currently available in this center to test the use of GATE application on the grid through GENIUS. This portal will allow in a long term to use GATE application in brachytherapy and radiotherapy treatment planning using medical data (medical images, DICOM, binary data dose calculation in the heterogeneous mediums) and to analyze the results obtained in visual form. Other functionalities are under development and will make possible to register medical data on grid storages elements and to manage them. However, these data must be anonymised before their recording on the grid. Their access via the GENIUS portal must be made safe and fast (compared simulation computing time). In order to be sure that the medical data are accessible for calculations, their replication on various storage element (SE) should be possible. The grid services give the possibility of managing this information in a free way and transparently. Operations of data handling and catalogues on the grid are ensured by the Replica Manager system which integrates all tools making it possible to manage data on the grid. The computing grid give promising results and meet a definite need: reach acceptable computing time for a future use of Monte Carlo simulations for treatment planning in brachytherapy and radiotherapy

    Use of the GATE Monte Carlo package for dosimetry applications

    Get PDF
    6 pages, 3 figures - submitted to NIM A, presented by D. VisvikisInternational audienceOne of the roles for MC simulation studies is in the area of dosimetry. A number of different codes dedicated to dosimetry applications are available and widely used today, such as MCNP, EGSnrc and PTRAN. However, such codes do not easily facilitate the description of complicated 3D sources or emission tomography systems and associated data flow, which may be useful in different dosimetry application domains. Such problems can be overcome by the use of specific MC codes such as GATE, which is based on Geant4 libraries, providing a scripting interface with a number of advantages for the simulation of SPECT and PET systems. Despite this potential, its major disadvantage is in terms of efficiency involving long execution times for applications such as dosimetry. The strong points and disadvantages of GATE in comparison to other dosimetry specific codes are discussed and illustrated in terms of accuracy, efficiency and flexibility. A number of features, such as the use of voxelised and moving sources, as well as developments such as advanced visualisation tools and the development of dose estimation maps allowing GATE to be used for dosimetry applications are presented. In addition, different examples from dosimetry applications with GATE are given. Finally, future directions with respect to the use of GATE for dosimetry applications are outlined

    GATE : a simulation toolkit for PET and SPECT

    Get PDF
    Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/

    Partial tetraplegic syndrome as a complication of a mobilizing/manipulating procedure of the cervical spine in a man with Forestier's disease: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Even if performed by qualified physical therapists, spinal manipulation and mobilization can cause adverse events. This holds true particularly for the cervical spine. In light of the substantial risks, the benefits of cervical spine manipulation may be outweighed by the possibility of further injury.</p> <p>Case presentation</p> <p>We present the case of a 56-year-old Caucasian man with Forestier's disease who went to see a physiotherapist to relieve his aching neck while on a holiday trip. Following the procedure, he was transferred to a local hospital with a partial tetraplegic syndrome due to a cervical 6/7 luxation fracture. Reportedly, the physiotherapist took neither a detailed history, nor adequate diagnostic measures.</p> <p>Conclusions</p> <p>This case highlights the potentially dangerous complications associated with cervical spine mobilization/manipulation. If guidelines concerning cervical spine mobilization and manipulation practices had been followed, this adverse event could have been avoided.</p

    Pudendal nerve decompression in perineology : a case series

    Get PDF
    BACKGROUND: Perineodynia (vulvodynia, perineal pain, proctalgia), anal and urinary incontinence are the main symptoms of the pudendal canal syndrome (PCS) or entrapment of the pudendal nerve. The first aim of this study was to evaluate the effect of bilateral pudendal nerve decompression (PND) on the symptoms of the PCS, on three clinical signs (abnormal sensibility, painful Alcock's canal, painful "skin rolling test") and on two neurophysiological tests: electromyography (EMG) and pudendal nerve terminal motor latencies (PNTML). The second aim was to study the clinical value of the aforementioned clinical signs in the diagnosis of PCS. METHODS: In this retrospective analysis, the studied sample comprised 74 female patients who underwent a bilateral PND between 1995 and 2002. To accomplish the first aim, the patients sample was compared before and at least one year after surgery by means of descriptive statistics and hypothesis testing. The second aim was achieved by means of a statistical comparison between the patient's group before the operation and a control group of 82 women without any of the following signs: prolapse, anal incontinence, perineodynia, dyschesia and history of pelvi-perineal surgery. RESULTS: When bilateral PND was the only procedure done to treat the symptoms, the cure rates of perineodynia, anal incontinence and urinary incontinence were 8/14, 4/5 and 3/5, respectively. The frequency of the three clinical signs was significantly reduced. There was a significant reduction of anal and perineal PNTML and a significant increase of anal richness on EMG. The Odd Ratio of the three clinical signs in the diagnosis of PCS was 16,97 (95% CI = 4,68 – 61,51). CONCLUSION: This study suggests that bilateral PND can treat perineodynia, anal and urinary incontinence. The three clinical signs of PCS seem to be efficient to suspect this diagnosis. There is a need for further studies to confirm these preliminary results

    Altered muscular activation during prone hip extension in women with and without low back pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Altered movement pattern has been associated with the development of low back pain (LBP). The purpose of this study was to investigate the activity pattern of the ipsilateral erector spinae (IES) and contralateral erectorspinae (CES), gluteus maximus (GM) and hamstring (HAM) muscles during prone hip extension (PHE) test in women with and without LBP. A cross-sectional non-experimental design was used.</p> <p>Methods</p> <p>Convenience sample of 20 female participated in the study. Subjects were categorized into two groups: with LBP (n = 10) and without LBP (n = 10). The electromyography (EMG) signal amplitude of the tested muscles during PHE (normalized to maximum voluntary electrical activity (MVE)) was measured in the dominant lower extremity in all subjects.</p> <p>Results</p> <p>Statistical analysis revealed greater normalized EMG signal amplitude in women with LBP compared to non-LBP women. There was significant difference in EMG activity of the IES (P = 0.03) and CES (P = 0.03) between two groups. However, no significant difference was found in EMG signals of the GM (P = 0.11) and HAM (P = 0.14) among two groups.</p> <p>Conclusion</p> <p>The findings of this study demonstrated altered activation pattern of the lumbo-pelvic muscles during PHE in the women with chronic LBP. This information is important for investigators using PHE as either an evaluation tool or a rehabilitation exercise.</p

    Application of a diagnosis-based clinical decision guide in patients with neck pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Neck pain (NP) is a common cause of disability. Accurate and efficacious methods of diagnosis and treatment have been elusive. A diagnosis-based clinical decision guide (DBCDG; previously referred to as a diagnosis-based clinical decision rule) has been proposed which attempts to provide the clinician with a systematic, evidence-based guide in applying the biopsychosocial model of care. The approach is based on three questions of diagnosis. The purpose of this study is to present the prevalence of findings using the DBCDG in consecutive patients with NP.</p> <p>Methods</p> <p>Demographic, diagnostic and baseline outcome measure data were gathered on a cohort of NP patients examined by one of three examiners trained in the application of the DBCDG.</p> <p>Results</p> <p>Data were gathered on 95 patients. Signs of visceral disease or potentially serious illness were found in 1%. Centralization signs were found in 27%, segmental pain provocation signs were found in 69% and radicular signs were found in 19%. Clinically relevant myofascial signs were found in 22%. Dynamic instability was found in 40%, oculomotor dysfunction in 11.6%, fear beliefs in 31.6%, central pain hypersensitivity in 4%, passive coping in 5% and depression in 2%.</p> <p>Conclusion</p> <p>The DBCDG can be applied in a busy private practice environment. Further studies are needed to investigate clinically relevant means to identify central pain hypersensitivity, oculomotor dysfunction, poor coping and depression, correlations and patterns among the diagnostic components of the DBCDG as well as inter-examiner reliability, validity and efficacy of treatment based on the DBCDG.</p
    corecore