825 research outputs found

    Ground State of the Hydrogen Atom via Dirac Equation in a Minimal Length Scenario

    Full text link
    In this work we calculate the correction to the ground state energy of the hydrogen atom due to contributions arising from the presence of a minimal length. The minimal length scenario is introduced by means of modifying the Dirac equation through a deformed Heisenberg algebra (kempf algebra). With the introduction of the Coulomb potential in the new Dirac energy operator, we calculate the energy shift of the ground state of the hydrogen atom in first order of the parameter related to the minimal length via perturbation theory.Comment: 11 page

    A bizarre foreign body in the appendix: A case report

    Get PDF
    Foreign bodies are rare causes of appendicitis and, in most cases, ingested foreign bodies pass through the alimentary tract asymptomatically. However, ingested foreign bodies may sometimes remain silent within the appendix for many years without an inflammatory response. Despite the fact that cases of foreign-body-induced appendicitis have been documented, sharp and pointed objects are more likely to cause perforations and abscesses, and present more rapidly after ingestion. Various materials, such as needles and drill bits, as well as organic matter, such as seeds, have been implicated as causes of acute appendicitis. Clinical presentation can vary from hours to years. Blunt foreign bodies are more likely to remain dormant for longer periods and cause appendicitis through obstruction of the appendiceal lumen. We herein describe a patient presenting with a foreign body in his appendix which had been swallowed 15 years previously. The contrast between the large size of the foreign body, the long clinical history without symptoms and the total absence of any histological inflammation was notable. We suggest that an elective laparoscopic appendectomy should be offered to such patients as a possible management optio

    Correlation of Early Outcomes and Intradiscal Interleukin-6 Expression in Lumbar Fusion Patients.

    Get PDF
    OBJECTIVE: To determine if there is correlation between intradiscal levels of interleukin-6 (IL-6) and early outcome measures in patients undergoing lumbar fusion for painful disc degeneration. METHODS: Intervertebral disc tissue was separated into annulus fibrosus/nucleus pulposus and cultured separately in vitro in serum-free medium (Opti-MEM). Conditioned media was collected after 48 hours. The concentration of IL-6 was quantified using enzyme-linked immunosorbent assay. Pearson correlation coefficients quantified relationships between IL-6 levels and pre- and postoperative visual analogue scale (VAS) back pain and Oswestry Disability Index (ODI), as well as change in VAS/ODI. RESULTS: Sixteen discs were harvested from 9 patients undergoing anterior lumbar interbody fusion (mean age, 47.4 years; range, 21-70 years). Mean preoperative and 6-month postoperative VAS were 8.1 and 3.7, respectively. Mean preoperative and postoperative ODI were 56.2 and 25.6, respectively. There were significant positive correlations between IL-6 expression and postoperative VAS (ρ = 0.38, p = 0.048) and ODI (ρ = 0.44, p = 0.02). No significant correlations were found between intradiscal IL-6 expression and preoperative VAS (ρ = -0.12, p = 0.54). Trends were seen associating IL-6 expression and change in VAS/ODI (ρ = -0.35 p = 0.067; ρ = -0.34, p = 0.08, respectively). A trend associated IL-6 and preoperative ODI (ρ = 0.36, p = 0.063). CONCLUSION: The direct association between IL-6 expression and VAS/ODI suggests patients with elevated intradiscal cytokine expression may have worse early outcomes than those with lower expression of IL-6 after surgery for symptomatic disc degeneration

    Density correlations in ultracold atomic Fermi gases

    Get PDF
    We investigate density fluctuations in a coherent ensemble of interacting fermionic atoms. Adapting the concept of full counting statistics, well-known from quantum optics and mesoscopic electron transport, we study second-order as well as higher-order correlators of density fluctuations. Using the mean-field BCS state to describe the whole interval between the BCS limit and the BEC limit, we obtain an exact expression for the cumulant-generating function of the density fluctuations of an atomic cloud. In the two-dimensional case, we obtain a closed analytical expression. Poissonian fluctuations of a molecular condensate on the BEC side are strongly suppressed on the BCS side. The size of the fluctuations in the BCS limit is a direct measure of the pairing potential. We also discuss the BEC-BCS crossover of the third cumulant and the temperature dependence of the second cumulant.Comment: 4 pages, 4 figures. To appear in Phys. Rev. A. New calculation of the bin statistics of a free Bose gas; updated and extended bibliograph

    MRI analysis for Hippocampus segmentation on a distributed infrastructure

    Get PDF
    Medical image computing raises new challenges due to the scale and the complexity of the required analyses. Medical image databases are currently available to supply clinical diagnosis. For instance, it is possible to provide diagnostic information based on an imaging biomarker comparing a single case to the reference group (controls or patients with disease). At the same time many sophisticated and computationally intensive algorithms have been implemented to extract useful information from medical images. Many applications would take great advantage by using scientific workflow technology due to its design, rapid implementation and reuse. However this technology requires a distributed computing infrastructure (such as Grid or Cloud) to be executed efficiently. One of the most used workflow manager for medical image processing is the LONI pipeline (LP), a graphical workbench developed by the Laboratory of Neuro Imaging (http://pipeline.loni.usc.edu). In this article we present a general approach to submit and monitor workflows on distributed infrastructures using LONI Pipeline, including European Grid Infrastructure (EGI) and Torque-based batch farm. In this paper we implemented a complete segmentation pipeline in brain magnetic resonance imaging (MRI). It requires time-consuming and data-intensive processing and for which reducing the computing time is crucial to meet clinical practice constraints. The developed approach is based on web services and can be used for any medical imaging application

    Vertebral Body Stapling versus Bracing for Patients with High-Risk Moderate Idiopathic Scoliosis.

    Get PDF
    Purpose. We report a comparison study of vertebral body stapling (VBS) versus a matched bracing cohort for immature patients with moderate (25 to 44°) idiopathic scoliosis (IS). Methods. 42 of 49 consecutive patients (86%) with IS were treated with VBS and followed for a minimum of 2 years. They were compared to 121 braced patients meeting identical inclusion criteria. 52 patients (66 curves) were matched according to age at start of treatment (10.6 years versus 11.1 years, resp. [P = 0.07]) and gender. Results. For thoracic curves 25-34°, VBS had a success rate (defined as curve progressio

    Cross-cultural adaptation and validation of the “spinal cord injury-falls concern scale” in the Italian population

    Get PDF
    Study design: Psychometrics study. Objective: The objective of this study was to develop an Italian version of the Spinal Cord Injury-Falls Concern Scale (SCI-FCS) and examine its reliability and validity. Setting: Multicenter study in spinal units in Northern and Southern Italy. The scale also was administered to non-hospitalized outpatient clinic patients. Methods: The original scale was translated from English to Italian using the “Translation and Cultural Adaptation of Patient-Reported Outcomes Measures” guidelines. The reliability and validity of the culturally adapted scale were assessed following the “Consensus-Based Standards for the Selection of Health Status Measurement Instruments” checklist. The SCI-FCS-I internal consistency, inter-rater, and intra-rater reliability were examined using Cronbach’s alpha coefficient and the intraclass correlation coefficient, respectively. Concurrent validity was evaluated using Pearson’s correlation coefficient with the Italian version of the short form of the Wheelchair Use Confidence Scale for Manual Wheelchair Users (WheelCon-M-I-short form). Results: The Italian version of the SCI-FCS-I was administered to 124 participants from 1 June to 30 September 2017. The mean ± SD of the SCI-FCS-I score was 16.73 ± 5.88. All SCI-FCS items were either identical or similar in meaning to the original version’s items. Cronbach’s α was 0.827 (p < 0.01), the inter-rater reliability was 0.972 (p < 0.01), and the intra-rater reliability was 0.973 (p < 0.01). Pearson’s correlation coefficient of the SCI-FCS-I scores with the WheelCon-M-I-short form was 0.56 (p < 0.01). Conclusions: The SCI-FCS-I was found to be reliable and a valid outcome measure for assessing manual wheelchair concerns about falling in the Italian population

    A statistical approach to violin evaluation

    Get PDF
    Comparing violins requires competence and involves both subjective and objective evaluations. In this manuscript, vibration tests were performed on a set of 25 violins, both historical and new. The resulting bridge admittances were modeled in the low and mid-frequency ranges through a set of objective features. Once projected into the new representation, the bridge admittances of three historical violins made by Stradivari and a famous reproduction revealed high similarity. PCA highlighted the importance of signature mode frequencies, bridge hill behavior, and signature mode amplitudes in distinguishing different violins

    Assessment of Cardiorespiratory Interactions During Spontaneous and Controlled Breathing: Linear Parametric Analysis

    Get PDF
    In this work, we perform a linear parametric analysis of cardiorespiratory interactions in bivariate time series of heart period (HP) and respiration (RESP) measured in 19 healthy subjects during spontaneous breathing and controlled breathing at varying breathing frequency. The analysis is carried out computing measures of the total and causal interaction between HP and RESP variability in both time and frequency domains (low- and high-frequency, LF and HF). Results highlight strong cardiorespiratory interactions in the time domain and within the HF band that are not affected by the paced breathing condition. Interactions in the LF band are weaker and prevalent along the direction from HP to RESP, but result more influenced by the shift from spontaneous to controlled respiration
    corecore