184 research outputs found

    Characterization of Spatial Coherence of Synchrotron Radiation with Non-Redundant Arrays of Apertures

    Full text link
    We present a method to characterize the spatial coherence of soft X-ray radiation from a single diffraction pattern. The technique is based on scattering from non-redundant arrays (NRA) of slits and records the degree of spatial coherence at several relative separations from one to 15 microns, simultaneously. Using NRAs we measured the transverse coherence of the X-ray beam at the XUV X-ray beamline P04 of the PETRA III synchrotron storage ring as a function of different beam parameters. To verify the results obtained with the NRAs additional Young's double pinhole experiments were conducted and show good agreement.Comment: 15 pages, 6 figures, 2 tables, 42 reference

    Model study for the nonequlibrium magnetic domain structure during the growth of nanostructured ultrathin films

    Full text link
    The nonequilibrium magnetic domain structure of growing ultrathin ferromagnetic films with a realistic atomic structure is studied as a function of coverage and temperature. We apply a kinetic Monte Carlo method to a micromagnetic model describing the transition from superparamagnetic islands at low coverages to a closed ferromagnetic film. The magnetic relaxation and the island growth happen simultaneously. Near the percolation threshold a metastable magnetic domain structure is obtained with an average domain area ranging between the area of individual magnetic islands and the area of the large domains observed for thicker ferromagnetic films. We conclude that this micro-domain structure is controlled and stabilized by the nonuniform atomic nanostructure of the ultrathin film, causing a random interaction between magnetic islands with varying sizes and shapes. The average domain area and domain roughness are determined. A maximum of the domain area and a minimum of the domain roughness are obtained as a function of the temperature.Comment: 19 pages, 4 Postscript figures; to be published in J. Magn. Magn. Mater., accepted (2001); completely revised manuscrip

    Enhanced Magneto-Optical Edge Excitation in Nanoscale Magnetic Disks

    Get PDF
    We report unexpected enhancements of the magneto-optical effect in ferromagnetic Permalloy disks of diameter D < 400 nm. The effect becomes increasingly pronounced for smaller D, reaching more than a 100% enhancement for D ¼ 100 nm samples. By means of experiments and simulations, the origin of this effect is identified as a nanoscale ring-shaped region at the disk edges, in which the magneto-optically induced electric polarization is enhanced. This leads to a modification of the electromagnetic near fields and causes the enhanced magneto-optical excitation, independent from any optical resonance.We acknowledge funding from the Basque Government (Program No. PI2012-47) and the Spanish Government (Project No.MAT2012-36844).Work at the Universidad de Cantabria has been supported by MICINN under Project No. FIS2013-45854-P

    Anisotropic susceptibility of ferromagnetic ultrathin Co films on vicinal Cu

    Get PDF
    We measure the magnetic susceptibility of ultrathin Co films with an in-plane uniaxial magnetic anisotropy grown on a vicinal Cu substrate. Above the Curie temperature the influence of the magnetic anisotropy can be investigated by means of the parallel and transverse susceptibilities along the easy and hard axes. By comparison with a theoretical analysis of the susceptibilities we determine the isotropic exchange interaction and the magnetic anisotropy. These calculations are performed in the framework of a Heisenberg model by means of a many-body Green's function method, since collective magnetic excitations are very important in two-dimensional magnets.Comment: 7 pages, 3 figure

    A new resorbable device for ligation of blood vessels - A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p

    Direct 2D spatial coherence determination using the Fourier analysis method Multi parameter characterization of the P04 beamline at PETRA III

    Get PDF
    We present a systematic 2D spatial-coherence analysis of the soft-X-ray beamline P04 at PETRA III for various beamline configurations. The influence of two different beam-defining apertures on the spatial coherence properties of the beam is discussed and optimal conditions for coherence-based experiments are found. A significant degradation of the spatial coherence in the vertical direction has been measured and sources of this degradation are identified and discussed. The Fourier-analysis method, which gives fast and simple access to the 2D spatial coherence function of the X-ray beam, is used for the experiment. Here, we exploit the charge scattering of a disordered nanodot sample allowing the use of arbitrary X-ray photon energies with this method
    corecore