279 research outputs found
A Raman Study of Morphotropic Phase Boundary in PbZr1-xTixO3 at low temperatures
Raman spectra of PbZr1-xTixO3 ceramics with titanium concentration varying
between 0.40 and 0.60 were measured at 7 K. By observing the
concentration-frequency dependence of vibrational modes, we identified the
boundaries among rhombohedral, monoclinic, and tetragonal ferroelectric phases.
The analysis of the spectra was made in the view of theory group analysis
making possible the assignment of some modes for the monoclinic phase.Comment: 5 pages, 4 figure
A Limited Role for Suppression in the Central Field of Individuals with Strabismic Amblyopia.
yesBackground: Although their eyes are pointing in different directions, people with long-standing strabismic amblyopia
typically do not experience double-vision or indeed any visual symptoms arising from their condition. It is generally
believed that the phenomenon of suppression plays a major role in dealing with the consequences of amblyopia and
strabismus, by preventing images from the weaker/deviating eye from reaching conscious awareness. Suppression is thus a
highly sophisticated coping mechanism. Although suppression has been studied for over 100 years the literature is
equivocal in relation to the extent of the retina that is suppressed, though the method used to investigate suppression is
crucial to the outcome. There is growing evidence that some measurement methods lead to artefactual claims that
suppression exists when it does not.
Methodology/Results: Here we present the results of an experiment conducted with a new method to examine the
prevalence, depth and extent of suppression in ten individuals with strabismic amblyopia. Seven subjects (70%) showed no
evidence whatsoever for suppression and in the three individuals who did (30%), the depth and extent of suppression was
small.
Conclusions: Suppression may play a much smaller role in dealing with the negative consequences of strabismic amblyopia
than previously thought. Whereas recent claims of this nature have been made only in those with micro-strabismus our
results show extremely limited evidence for suppression across the central visual field in strabismic amblyopes more
generally. Instead of suppressing the image from the weaker/deviating eye, we suggest the visual system of individuals with
strabismic amblyopia may act to maximise the possibilities for binocular co-operation. This is consistent with recent
evidence from strabismic and amblyopic individuals that their binocular mechanisms are intact, and that, just as in visual
normals, performance with two eyes is better than with the better eye alone in these individuals
Does police size matter?:A review of the evidence regarding restructuring police organisations
Restructuring and merging public sector organisations is often seen as a way to enhance efficiency and efficacy. There is ongoing debate about the impact of police force sizes, structures and mergers as police organisations attempt to adapt to reductions in their budgets and changes in patterns of criminality. The article reviews the evidence regarding key aspects of police reform: finding mixed evidence regarding the links between size and performance, while noting risks that mergers may impair local policing. The article discusses the impact of mergers on protective services, governance and accountability, while also discussing potential risks and opportunities associated with the merger process itself. The review finds significant gaps in the available evidence, and significant opportunities to expand the evidence base on this topic. Given current gaps in the evidence regarding size, efficacy and efficiency, it is important to give due consideration to symbolic and rhetorical aspects of mergers
Recommended from our members
Appearance concerns in ophthalmic patients
Aims: This study aimed to determine the psychosocial and appearance-related concerns of a sample of ophthalmic patients by measuring a range of psychological, social, and demographic factors.
Methods: Standardized psychological measures including anxiety, depression, appearance-related distress, self-discrepancy, appearance salience and valence were administered to 98 participants attending ophthalmic outpatient clinics in either London, Bristol, Sheffield or Bradford. Differences between groups were explored using t-tests and ANOVA, relationships between all variables were investigated using Pearson's correlation coefficient.
Results: Although mean scores for psychological adjustment were within the normal range, some participants were experiencing considerable levels of generalized anxiety. Being older, male, and married or living with a partner was related to significantly better adjustment. Better adjustment was also related to a less visible area of concern, greater disguisability of the affected area, a more positive evaluation of their own appearance, less engagement in comparing themselves with others, greater feelings of being accepted by others, appearance being less important to their self-concept, and a smaller discrepancy between the persons ideal and actual appearance.
Conclusions: A majority of ophthalmic patients adjust positively to the demands placed on them. By identifying the variables that are associated with successful adaptation, the specific psychological interventions and appropriate systems of support can be put in place to help those who are adversely affected
Semi-Empirical Topological Method for Prediction of the Relative Retention Time of Polychlorinated Biphenyl Congeners on 18 Different HR GC Columns
High resolution gas chromatographic relative retention time (HRGC-RRT) models were developed to predict relative retention times of the 209 individual polychlorinated biphenyls (PCBs) congeners. To estimate and predict the HRGC-RRT values of all PCBs on 18 different stationary phases, a multiple linear regression equation of the form RRT = ao + a1 (no. o-Cl) + a2 (no. m-Cl) + a3 (no. p-Cl) + a4 (VM or SM) was used. Molecular descriptors in the models included the number of ortho-, meta-, and para-chlorine substituents (no. o-Cl, m-Cl and p-Cl, respectively), the semi-empirically calculated molecular volume (VM), and the molecular surface area (SM). By means of the final variable selection method, four optimal semi-empirical descriptors were selected to develop a QSRR model for the prediction of RRT in PCBs with a correlation coefficient between 0.9272 and 0.9928 and a leave-one-out cross-validation correlation coefficient between 0.9230 and 0.9924 on each stationary phase. The root mean squares errors over different 18 stationary phases are within the range of 0.0108–0.0335. The accuracy of all the developed models were investigated using cross-validation leave-one-out (LOO), Y-randomization, external validation through an odd–even number and division of the entire data set into training and test sets
Psychological causes of non-compliance with electronically monitored occlusion therapy for amblyopia
Binocular summation and other forms of non-dominant eye contribution in individuals with strabismic amblyopia during habitual viewing
YesAdults with amblyopia ('lazy eye'), long-standing strabismus (ocular misalignment) or both typically do not experience visual symptoms because the signal from weaker eye is given less weight than the signal from its fellow. Here we examine the contribution of the weaker eye of individuals with strabismus and amblyopia with both eyes open and with the deviating eye in its anomalous motor position. The task consisted of a blue-on-yellow detection task along a horizontal line across the central 50 degrees of the visual field. We compare the results obtained in ten individuals with strabismic amblyopia with ten visual normals. At each field location in each participant, we examined how the sensitivity exhibited under binocular conditions compared with sensitivity from four predictions, (i) a model of binocular summation, (ii) the average of the monocular sensitivities, (iii) dominant-eye sensitivity or (iv) non-dominant-eye sensitivity. The proportion of field locations for which the binocular summation model provided the best description of binocular sensitivity was similar in normals (50.6%) and amblyopes (48.2%). Average monocular sensitivity matched binocular sensitivity in 14.1% of amblyopes' field locations compared to 8.8% of normals'. Dominant-eye sensitivity explained sensitivity at 27.1% of field locations in amblyopes but 21.2% in normals. Non-dominant-eye sensitivity explained sensitivity at 10.6% of field locations in amblyopes but 19.4% in normals. Binocular summation provided the best description of the sensitivity profile in 6/10 amblyopes compared to 7/10 of normals. In three amblyopes, dominant-eye sensitivity most closely reflected binocular sensitivity (compared to two normals) and in the remaining amblyope, binocular sensitivity approximated to an average of the monocular sensitivities. Our results suggest a strong positive contribution in habitual viewing from the non-dominant eye in strabismic amblyopes. This is consistent with evidence from other sources that binocular mechanisms are frequently intact in strabismic and amblyopic individuals
- …