156 research outputs found
Triple product correlations in top squark decays
We propose several T-odd asymmetries in the decay chains of the top squarks
and and , for . We
calculate the asymmetries within the Minimal Supersymmetric Standard Model with
complex parameters , and . We give the analytic formulae for
the decay distributions. We present numerical results for the asymmetries and
estimate the event rates necessary to observe them. The largest T-odd asymmetry
can be as large as 40%.Comment: 26 pages, 5 figures; misprints corrected; reference adde
On the Quantization of the Chern-Simons Fields Theory on Curved Space-Times: the Coulomb Gauge Approach
We consider here the Chern-Simons field theory with gauge group SU(N) in the
presence of a gravitational background that describes a two-dimensional
expanding ``universe". Two special cases are treated here in detail: the
spatially flat {\it Robertson-Walker} space-time and the conformally static
space-times having a general closed and orientable Riemann surface as spatial
section. The propagator and the vertices are explicitely computed at the lowest
order in perturbation theory imposing the Coulomb gauge fixing.Comment: 15 pp., Preprint LMU-TPW 93-5, (Plain TeX + Harvmac
Accuracy and repeatability of wrist joint angles in boxing using an electromagnetic tracking system
© 2019, The Author(s). The hand-wrist region is reported as the most common injury site in boxing. Boxers are at risk due to the amount of wrist motions when impacting training equipment or their opponents, yet we know relatively little about these motions. This paper describes a new method for quantifying wrist motion in boxing using an electromagnetic tracking system. Surrogate testing procedure utilising a polyamide hand and forearm shape, and in vivo testing procedure utilising 29 elite boxers, were used to assess the accuracy and repeatability of the system. 2D kinematic analysis was used to calculate wrist angles using photogrammetry, whilst the data from the electromagnetic tracking system was processed with visual 3D software. The electromagnetic tracking system agreed with the video-based system (paired t tests) in both the surrogate ( 0.9). In the punch testing, for both repeated jab and hook shots, the electromagnetic tracking system showed good reliability (ICCs > 0.8) and substantial reliability (ICCs > 0.6) for flexion–extension and radial-ulnar deviation angles, respectively. The results indicate that wrist kinematics during punching activities can be measured using an electromagnetic tracking system
On measurement of top polarization as a probe of production mechanisms at the LHC
In this note we demonstrate the use of top polarization in the study of resonances at the LHC, in the possible case where the dynamics implies
a non-zero top polarization. As a probe of top polarization we construct an
asymmetry in the decay-lepton azimuthal angle distribution (corresponding to
the sign of ) in the laboratory. The asymmetry is non-vanishing
even for a symmetric collider like the LHC, where a positive axis is not
uniquely defined. The angular distribution of the leptons has the advantage of
being a faithful top-spin analyzer, unaffected by possible anomalous
couplings, to linear order. We study, for purposes of demonstration, the case
of a as might exist in the little Higgs models. We identify kinematic cuts
which ensure that our asymmetry reflects the polarization in sign and
magnitude. We investigate possibilities at the LHC with two energy options:
TeV and TeV, as well as at the Tevatron. At the
LHC the model predicts net top quark polarization of the order of a few per
cent for GeV, being as high as for a smaller mass
of the of GeV and for the largest allowed coupling in the model, the
values being higher for the TeV option. These polarizations translate to a
deviation from the standard-model value of azimuthal asymmetry of up to about
() for () TeV LHC, whereas for the Tevatron, values as high as
are attained. For the TeV LHC with an integrated luminosity of 10
fb, these numbers translate into a sensitivity over a large
part of the range GeV.Comment: 28 page, LaTeX, requires JHEP style file, 12 figures. Typos corrected
and references adde
Summary of the Activities of the Working Group I on High Energy and Collider Physics
This is a summary of the projects undertaken by the Working Group I on High
Energy Collider Physics at the Eighth Workshop on High Energy Physics
Phenomenology (WHEPP8) held at the Indian Institute of Technology, Mumbai,
January 5-16, 2004. The topics covered are (i) Higgs searches (ii)
supersymmetry searches (iii) extra dimensions and (iv) linear collider.Comment: summary of Working Group I at the Eighth Workshop on High Energy
Physics Phenomenology (WHEPP8), I.I.T., Mumbai, January 5-16, 200
CP violation in sbottom decays
We study CP asymmetries in two-body decays of bottom squarks into charginos
and tops. These asymmetries probe the SUSY CP phases of the sbottom and the
chargino sector in the Minimal Supersymmetric Standard Model. We identify the
MSSM parameter space where the CP asymmetries are sizeable, and analyze the
feasibility of their observation at the LHC. As a result, potentially
detectable CP asymmetries in sbottom decays are found, which motivates further
detailed experimental studies for probing the SUSY CP phases.Comment: 29 pages, 7 figure
Electron and Neutron Electric Dipole Moments in the Constrained MSSM
We analyze the effects of CP-violating phases on the electric dipole moment
(EDM) of electron and neutron in the constrained minimal supersymmetric model.
We find that the phases phi_{\mu} and phi_{A_0} have to be strongly correlated,
in particular for small values of the SUSY mass parameters. We calculate the
neutron EDM in two different models, the Quark-Parton Model and the Chiral
Quark Model. It turns out that the predictions are quite sensitive to the model
used. We show parameter regions in the M_0-M_1/2 plane which are excluded by
considering simultaneously the experimental bounds of both electron and neutron
EDM, assuming specific values for the phases phi_{\mu} and phi_{A_0}.Comment: 23 pages LaTeX with 8 figures included, using the epsfig-stylefil
Range of shoulder motion in patients with adhesive capsulitis; Intra-tester reproducibility is acceptable for group comparisons
<p>Abstract</p> <p>Background</p> <p>Measurements of range of motion play a key role in shoulder research. The purpose of this study is to investigate intra-observer reproducibility of measurements of active and passive range of motion in patients with adhesive capsulitis.</p> <p>Methods</p> <p>The study was carried out in a population consisting of 32 patients with clinical signs of adhesive capsulitis. A specified measurement protocol was used, and range of motion in affected and non-affected shoulders was measured twice for each patient with a one-week interval.</p> <p>Results</p> <p>For most of the investigated individual movements, test-retest differences in range of motion score of more than approximately 15° are not likely to occur as a result of measurement error only. Point-estimates for the intraclass correlation coefficient ranged from 0.61 to 0.93.</p> <p>Conclusion</p> <p>Range of motion of patients with adhesive capsulitis can be measured with acceptable reproducibility in settings where groups are compared. Scores for individual patients should be interpreted with caution.</p
Mechanosensitivity during lower extremity neurodynamic testing is diminished in individuals with Type 2 Diabetes Mellitus and peripheral neuropathy: a cross sectional study
<p>Abstract</p> <p>Background</p> <p>Type 2 Diabetes Mellitus (T2DM) and diabetic symmetrical polyneuropathy (DSP) impact multiple modalities of sensation including light touch, temperature, position sense and vibration perception. No study to date has examined the mechanosensitivity of peripheral nerves during limb movement in this population. The objective was to determine the unique effects T2DM and DSP have on nerve mechanosensitivity in the lower extremity.</p> <p>Methods</p> <p>This cross-sectional study included 43 people with T2DM. Straight leg raise neurodynamic tests were performed with ankle plantar flexion (PF/SLR) and dorsiflexion (DF/SLR). Hip flexion range of motion (ROM), lower extremity muscle activity and symptom profile, intensity and location were measured at rest, first onset of symptoms (P1) and maximally tolerated symptoms (P2).</p> <p>Results</p> <p>The addition of ankle dorsiflexion during SLR testing reduced the hip flexion ROM by 4.3° ± 6.5° at P1 and by 5.4° ± 4.9° at P2. Individuals in the T2DM group with signs of severe DSP (n = 9) had no difference in hip flexion ROM between PF/SLR and DF/SLR at P1 (1.4° ± 4.2°; paired t-test p = 0.34) or P2 (0.9° ± 2.5°; paired t-test p = 0.31). Movement induced muscle activity was absent during SLR with the exception of the tibialis anterior during DF/SLR testing. Increases in symptom intensity during SLR testing were similar for both PF/SLR and DF/SLR. The addition of ankle dorsiflexion induced more frequent posterior leg symptoms when taken to P2.</p> <p>Conclusions</p> <p>Consistent with previous recommendations in the literature, P1 is an appropriate test end point for SLR neurodynamic testing in people with T2DM. However, our findings suggest that people with T2DM and severe DSP have limited responses to SLR neurodynamic testing, and thus may be at risk for harm from nerve overstretch and the information gathered will be of limited clinical value.</p
Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer
BACKGROUND: Reproducible measurements of the range of motion are an important prerequisite for the interpretation of study results. The digital inclinometer is considered to be a useful instrument because it is inexpensive and easy to use. No previous study assessed inter-observer reproducibility of range of motion measurements with a digital inclinometer by physical therapists in a large sample of patients. METHODS: Two physical therapists independently measured the passive range of motion of the glenohumeral abduction and the external rotation in 155 patients with shoulder pain. Agreement was quantified by calculation of the mean differences between the observers and the standard deviation (SD) of this difference and the limits of agreement, defined as the mean difference ± 1.96*SD of this difference. Reliability was quantified by means of the intraclass correlation coefficient (ICC). RESULTS: The limits of agreement were 0.8 ± 19.6 for glenohumeral abduction and -4.6 ± 18.8 for external rotation (affected side) and quite similar for the contralateral side and the differences between sides. The percentage agreement within 10° for these measurements were 72% and 70% respectively. The ICC ranged from 0.28 to 0.90 (0.83 and 0.90 for the affected side). CONCLUSIONS: The inter-observer agreement was found to be poor. If individual patients are assessed by two different observers, differences in range of motion of less than 20–25 degrees can not be distuinguished from measurement error. In contrast, acceptable reliability was found for the inclinometric measurements of the affected side and the differences between the sides, indicating that the inclimeter can be used in studies in which groups are compared
- …