694 research outputs found

    Pick your carats: nanoparticles of gold–silver–copper alloy produced in vivo

    Get PDF
    Abstract Engineered gold nanoparticle catalysts containing a mixture of metals enable enhanced specificity and reactivity. We report the synthesis by plants of mixed metal nanoparticles suggesting the possibility of using plants to produce catalysts of specific composition, perhaps even those difficult to synthesise by traditional methods. The nanoparticles contain Au, Ag and Cu as an alloy. The structure and composition are confirmed by scanning transmission electron microscopy (STEM) and energy dispersive X-ray analysis (EDX)

    Evaluating a Modular Decision Support Application For Colorectal Cancer Screening

    Get PDF
    BACKGROUND: There is a need for health information technology evaluation that goes beyond randomized controlled trials to include consideration of usability, cognition, feedback from representative users, and impact on efficiency, data quality, and clinical workflow. This article presents an evaluation illustrating one approach to this need using the Decision-Centered Design framework. OBJECTIVE: To evaluate, through a Decision-Centered Design framework, the ability of the Screening and Surveillance App to support primary care clinicians in tracking and managing colorectal cancer testing. METHODS: We leveraged two evaluation formats, online and in-person, to obtain feedback from a range primary care clinicians and obtain comparative data. Both the online and in-person evaluations used mock patient data to simulate challenging patient scenarios. Primary care clinicians responded to a series of colorectal cancer-related questions about each patient and made recommendations for screening. We collected data on performance, perceived workload, and usability. Key elements of Decision-Centered Design include evaluation in the context of realistic, challenging scenarios and measures designed to explore impact on cognitive performance. RESULTS: Comparison of means revealed increases in accuracy, efficiency, and usability and decreases in perceived mental effort and workload when using the Screening and Surveillance App. CONCLUSION: The results speak to the benefits of using the Decision-Centered Design approach in the analysis, design, and evaluation of Health Information Technology. Furthermore, the Screening and Surveillance App shows promise for filling decision support gaps in current electronic health records

    Dynamics of Wetting Fronts in Porous Media

    Full text link
    We propose a new phenomenological approach for describing the dynamics of wetting front propagation in porous media. Unlike traditional models, the proposed approach is based on dynamic nature of the relation between capillary pressure and medium saturation. We choose a modified phase-field model of solidification as a particular case of such dynamic relation. We show that in the traveling wave regime the results obtained from our approach reproduce those derived from the standard model of flow in porous media. In more general case, the proposed approach reveals the dependence of front dynamics upon the flow regime.Comment: 4 pages, 2 figures, revte

    Neonatal-onset multisystem inflammatory disease responsive to interleukin-1 beta inhibition

    Get PDF
    BACKGROUND:Neonatal-onset multisystem inflammatory disease is characterized by fever, urticarial rash, aseptic meningitis, deforming arthropathy, hearing loss, and mental retardation. Many patients have mutations in the cold-induced autoinflammatory syndrome 1 (CIAS1) gene, encoding cryopyrin, a protein that regulates inflammation.METHODS:We selected 18 patients with neonatal-onset multisystem inflammatory disease (12 with identifiable CIAS1 mutations) to receive anakinra, an interleukin-1-receptor antagonist (1 to 2 mg per kilogram of body weight per day subcutaneously). In 11 patients, anakinra was withdrawn at three months until a flare occurred. The primary end points included changes in scores in a daily diary of symptoms, serum levels of amyloid A and C-reactive protein, and the erythrocyte sedimentation rate from baseline to month 3 and from month 3 until a disease flare.RESULTS:All 18 patients had a rapid response to anakinra, with disappearance of rash. Diary scores improved (P<0.001) and serum amyloid A (from a median of 174 mg to 8 mg per liter), C-reactive protein (from a median of 5.29 mg to 0.34 mg per deciliter), and the erythrocyte sedimentation rate decreased at month 3 (all P<0.001), and remained low at month 6. Magnetic resonance imaging showed improvement in cochlear and leptomeningeal lesions as compared with baseline. Withdrawal of anakinra uniformly resulted in relapse within days; retreatment led to rapid improvement. There were no drug-related serious adverse events.CONCLUSIONS:Daily injections of anakinra markedly improved clinical and laboratory manifestations in patients with neonatal-onset multisystem inflammatory disease, with or without CIAS1 mutations

    Incorporating lessons from high-input research into a low-margin year

    Get PDF
    Increased soybean commodity prices in recent years have generated interest in developing high-input systems to increase yield. However, little information exists about the effects of input-intensive, high-yield management on soybean yield and profitability, as well as interactions with basic agronomic practices

    DOT tomography of the solar atmosphere. IV. Magnetic patches in internetwork areas

    Full text link
    We use G-band and Ca II H image sequences from the Dutch Open Telescope (DOT) to study magnetic elements that appear as bright points in internetwork parts of the quiet solar photosphere and chromosphere. We find that many of these bright points appear recurrently with varying intensity and horizontal motion within longer-lived magnetic patches. We develop an algorithm for detection of the patches and find that all patches identified last much longer than the granulation. The patches outline cell patterns on mesogranular scales, indicating that magnetic flux tubes are advected by granular flows to mesogranular boundaries. Statistical analysis of the emergence and disappearance of the patches points to an average patch lifetime as long as 530+-50 min (about nine hours), which suggests that the magnetic elements constituting strong internetwork fields are not generated by a local turbulent dynamo.Comment: 8 pages, 6 figure

    Accuracy of popular automatic QT Interval algorithms assessed by a 'Gold Standard' and comparison with a Novel method: computer simulation study

    Get PDF
    BACKGROUND: Accurate measurement of the QT interval is very important from a clinical and pharmaceutical drug safety screening perspective. Expert manual measurement is both imprecise and imperfectly reproducible, yet it is used as the reference standard to assess the accuracy of current automatic computer algorithms, which thus produce reproducible but incorrect measurements of the QT interval. There is a scientific imperative to evaluate the most commonly used algorithms with an accurate and objective 'gold standard' and investigate novel automatic algorithms if the commonly used algorithms are found to be deficient. METHODS: This study uses a validated computer simulation of 8 different noise contaminated ECG waveforms (with known QT intervals of 461 and 495 ms), generated from a cell array using Luo-Rudy membrane kinetics and the Crank-Nicholson method, as a reference standard to assess the accuracy of commonly used QT measurement algorithms. Each ECG contaminated with 39 mixtures of noise at 3 levels of intensity was first filtered then subjected to three threshold methods (T1, T2, T3), two T wave slope methods (S1, S2) and a Novel method. The reproducibility and accuracy of each algorithm was compared for each ECG. RESULTS: The coefficient of variation for methods T1, T2, T3, S1, S2 and Novel were 0.36, 0.23, 1.9, 0.93, 0.92 and 0.62 respectively. For ECGs of real QT interval 461 ms the methods T1, T2, T3, S1, S2 and Novel calculated the mean QT intervals(standard deviations) to be 379.4(1.29), 368.5(0.8), 401.3(8.4), 358.9(4.8), 381.5(4.6) and 464(4.9) ms respectively. For ECGs of real QT interval 495 ms the methods T1, T2, T3, S1, S2 and Novel calculated the mean QT intervals(standard deviations) to be 396.9(1.7), 387.2(0.97), 424.9(8.7), 386.7(2.2), 396.8(2.8) and 493(0.97) ms respectively. These results showed significant differences between means at >95% confidence level. Shifting ECG baselines caused large errors of QT interval with T1 and T2 but no error with Novel. CONCLUSION: The algorithms T2, T1 and Novel gave low coefficients of variation for QT measurement. The Novel technique gave the most accurate measurement of QT interval, T3 (a differential threshold method) was the next most accurate by a large margin. The objective and accurate 'gold standard' presented in this paper may be useful to assess new QT measurement algorithms. The Novel algorithm may prove to be more accurate and reliable method to measure the QT interval

    Solar cell process development in the european integrated project crystalclear

    Get PDF
    CrystalClear is a large integrated project funded by the European Commission that aims to drastically reduce the cost of crystalline Si PV modules, down to 1 Euro/Wp. Among the different subprojects, the one dealing with the development of advanced solar cells is relatively large (with 11 partners out of the 15 Crystal Clear partners taking part) and has a crucial role. The goal of the subproject is to develop cell design concepts and manufacturing processes that would enable a reduction in the order of 40% of the cell processing costs per Wp. In this paper, we give an overview of all the development work that has taken place in the CrystalClear solar cells subproject so far. World class results have been achieved, particularly on high efficiency cells on Si ribbons, and on industrial-type solar cells on very thin (120 (j.m thick) substrates

    Routine versus on demand removal of the syndesmotic screw; a protocol for an international randomised controlled trial (RODEO-trial)

    Get PDF
    Background: Syndesmotic injuries are common and their incidence is rising. In case of surgical fixation of the syndesmosis a metal syndesmotic screw is used most often. It is however unclear whether this screw needs to be removed routinely after the syndesmosis has healed. Traditionally the screw is removed after six to 12 weeks as it is thought to hamper ankle functional and to be a source of pain. Some studies however suggest this is only the case in a minority of patients. We therefore aim to investigate the effect of retaining the syndesmotic screw on functional outcome. Design: This is a pragmatic international multicentre randomised controlled trial in patients with an acute syndesmotic injury for which a metallic syndesmotic screw was placed. Patients will be randomised to either routine removal of the syndesmotic screw or removal on demand. Primary outcome is functional recovery at 12 months measured with the Olerud-Molander Score. Secondary outcomes are quality of life, pain and costs. In total 194 patients will be needed to demonstrate non-inferiority between the two interventions at 80% power and a significance level of 0.025 including 15% loss to follow-up. Discussion: If removal on demand of the syndesmotic screw is non-inferior to routine removal in terms of functional outcome, this will offer a strong argument to adopt this as standard practice of care. This means that patients will not have to undergo a secondary procedure, leading to less complications and subsequent lower costs.Peer reviewe
    • …
    corecore