70,283 research outputs found

    Computer design of extension springs

    Get PDF
    Computer program speeds up design process of tension springs and simultaneously optimizes the design by varying the input

    Prediction of pump cavitation performance

    Get PDF
    A method for predicting pump cavitation performance with various liquids, liquid temperatures, and rotative speeds is presented. Use of the method requires that two sets of test data be available for the pump of interest. Good agreement between predicted and experimental results of cavitation performance was obtained for several pumps operated in liquids which exhibit a wide range of properties. Two cavitation parameters which qualitatively evaluate pump cavitation performance are also presented

    Editorial

    Get PDF
    The University's Assessment, Learning and Teaching strategy commits us to publishing a journal showcasing staff activities in relation to Assessment, Learning and Teaching. The Assessment, Learning and Teaching Journal is practice-based, reflective and pragmatic, and comprises papers of up to 1,500 words and book reviews of up to 200 words. The journal is refereed, all submissions being reviewed by two reviewers. It is normally published three times a year both in hard copy and electronically

    Comparison of analytical and experimental performance of a wind-tunnel diffuser section

    Get PDF
    Wind tunnel diffuser performance is evaluated by comparing experimental data with analytical results predicted by an one-dimensional integration procedure with skin friction coefficient, a two-dimensional interactive boundary layer procedure for analyzing conical diffusers, and a two-dimensional, integral, compressible laminar and turbulent boundary layer code. Pressure, temperature, and velocity data for a 3.25 deg equivalent cone half-angle diffuser (37.3 in., 94.742 cm outlet diameter) was obtained from the one-tenth scale Altitude Wind Tunnel modeling program at the NASA Lewis Research Center. The comparison is performed at Mach numbers of 0.162 (Re = 3.097x19(6)), 0.326 (Re = 6.2737x19(6)), and 0.363 (Re = 7.0129x10(6)). The Reynolds numbers are all based on an inlet diffuser diameter of 32.4 in., 82.296 cm, and reasonable quantitative agreement was obtained between the experimental data and computational codes

    Aerodynamic performance of a 1.25-pressure-ratio axial-flow fan stage

    Get PDF
    Aerodynamic design parameters and overall and blade-element performances of a 1.25-pressure-ratio fan stage are reported. Detailed radial surveys were made over the stable operating flow range at rotative speeds from 70 to 120 percent of design speed. At design speed, the measured stage peak efficiency of 0.872 occurred at a weight flow of 34.92 kilograms per second and a pressure ratio of 1.242. Stage stall margin is about 20 percent based on the peak efficiency and stall conditions. The overall peak efficiency for the rotor was 0.911. The overall stage performance showed no significant change when the stators were positioned at 1, 2, or 4 chords downstream of the rotor

    Performance of single-stage axial-flow transonic compressor with rotor and stator aspect ratios of 1.19 and 1.26 respectively, and with design pressure ratio of 2.05

    Get PDF
    The overall and blade-element performances of a low-aspect-ratio transonic compressor stage are presented over the stable operating flow range for speeds from 50 to 100 percent of design. At design speed the rotor and stage achieved peak efficiencies of 0.876 and 0.840 at pressure ratios of 2.056 and 2.000, respectively. The stage stall margin at design speed was 10 percent

    Performance of single-stage axial-flow transonic compressor with rotor and stator aspect ratios of 1.63 and 1.78, respectively, and with design pressure ratio of 1.82

    Get PDF
    The overall and blade-element performance of a transonic compressor stage is presented over the stable operating flow range for speeds from 50 to 100 percent of design. The stage was designed for a pressure ratio of 1.82 at a flow 20.2 kg/sec and a tip speed of 455 m/sec. At design speed the stage achieved a peak efficiency of 0.821 at a pressure ratio of 1.817. The stage stall margin at design speed based on conditions at stall and peak efficiency was about 11 percent

    Performance of 1.15-pressure-ratio fan stage at several rotor blade setting angles with reverse flow

    Get PDF
    A 51 cm diameter low pressure ratio fan stage was tested in reverse flow. Survey flow data were taken over the range of rotative speed from 50 percent to 100 percent design speed at several rotor blade setting angles through both flat and feather pitch. Normal flow design values of pressure ratio and weight flow were 1.15 and 29.9 kg/sec with a rotor tip speed of 243.8 m/sec. The maximum thrust in reverse flow was 52.5 percent of design thrust in normal flow

    Performance of single-stage axial-flow transonic compressor with rotor and stator aspect ratios of 1.63 and 1.77, respectively, and with design pressure ratio of 2.05

    Get PDF
    The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range for speeds from 50 to 100 percent of design. The stage was designed for a pressure ratio of 2.05 at a flow of 20.2 kg/sec and a tip speed of 455 m/sec. At design speed the rotor and stage achieved peak efficiencies of 0.849 and 0.831, respectively, at the minimum flow condition. The stage stall point occurred at a flow higher than the design flow
    corecore