2,802 research outputs found

    On-line luminosity measurements at LEP

    Get PDF
    At each LEP interaction point, the luminosity is measured on-line by small angle Bhabha monitors. These monitors are optimized to observe in all bunches relative luminosity changes in a few seconds. The description of the detectors is given, together with the method used to calculate the luminosity after background correction. Optimization of the LEP performances was done with beam separation scans using the luminosity measurements. Those scans also provide a unique measurement of the vertical beam size at the interaction point

    Evaluation of demarcation line after epithelium-off iontophoresis corneal collagen cross-linking for progressive keratoconus

    Get PDF
    The aim of the study was to visualize and evaluate the characteristics and depth of the demarcation line with anterior segment optical coherence tomography (AS-OCT) after epithelium-off iontophoresis corneal collagen cross-linking (epi-off I-CXL). In this prospective, consecutive, single center study 18 eyes of 18 patients with keratoconus were involved. One month after epi-off I-CXL, all the patients underwent an AS-OCT scan to search for a demarcation line and its characteristics. The corneal stromal demarcation line was identified in all the eyes. Mean depth of the corneal stromal demarcation line was 261.8 ± 46.7 μm (range: 184 to 362 μm), at 56.7 ± 12% corneal depth. In conclusion, epi-off I-CXL determines a demarcation line that can be visualized with AS-OCT, which seems clearly distinguishable and similar to that created in standard CXL

    MAROC: Multi-Anode ReadOut Chip for MaPMTs

    No full text
    International audienceFor the ATLAS luminometer, made of Roman pots, a complete readout ASIC has been designed in 0.35 SiGe technology. It is used to readout 64 channels multi anode photomultipliers and supplies 64 trigger outputs and a multiplexed charge. Since its delivery in November 2005, the MAROC chip has been tested at LAL. Despite a substrate coupling effect which affects the performance when all channels are used in high gain, the chip has shown nice global behavior and it has been used during beam tests at CERN in October 2006

    Comparison of perioperative parameters in one-handed rotational phacoemulsification versus conventional phacoemulsification and femtosecond laser-assisted cataract surgery

    Get PDF
    AIM: To compare perioperative parameters of one-handed rotational phacoemulsification technique (one-handed phaco-roll) with each of other two techniques, “Divide et Conquer” and femtosecond laser-assisted cataract surgery (FLACS) METHODS: In this retrospective and comparative cohort study, eyes with uncomplicated cataract (nuclear density grade 2 to 3) treated routinely with one-handed phaco-roll (n=23; Group 1) or “Divide et Conquer” (n=23; Group 2) or FLACS (n=23; Group 3) were enrolled. Intraoperative parameters including effective phaco-time (EPt), ultrasound time (USt), aspiration time, surgical time, phacoemulsification (phaco)-power, balanced salt solution (BSS) use, cumulative dissipated energy (CDE) were recorded and compared. Clinical outcomes including best corrected visual acuity (BCVA), corneal endothelial cell density (ECD), endothelial cell loss (ECL), central corneal thickness (CCT) and central macular thickness (CMT), were assessed and compared pre-operatively and at 1mo after surgery. RESULTS: Aspiration and surgical time, and BSS used were lower in Group 1 (P<0.01) than other groups. EPt, phaco-power and CDE were lower in Group 1 (P<0.05) than Group 2 but not significantly different from Group 3. In Group 1, USt was lower (P<0.05) than Group 2 but higher (P<0.05) than Group 3. BCVA improved in all groups without significant difference between Group 1 and the other ones. No significant differences regarding all post-operative morphologic outcomes (ECD, ECL, CCT, CMT) were reported. No clinical complications occurred. CONCLUSION: One-handed phaco-roll seems to be less time-consuming than “Divide et Conquer” and FLACS and less energy-consuming than “Divide et Conquer”. Furthermore, one-handed phaco-roll seems to have an equal safety profile compared to the other two techniques

    A newly observed Effect affects the LEP Beam Energy

    Get PDF
    The LEP magnetic bending field and therefore the beam energy is changed by a current flow over the vacuum chamber. The current is created by trains travelling between the Geneva main station and destinations in France. Some of the rail current leaks into earth and returns to the power station via the LEP tunnel, where the vacuum chamber is one of the conductors. Train leakage currents penetrate LEP at the injection lines from the SPS close to IP1 and between IP5 and IP7, thereby interacting with the magnetic dipole field. The observed changes in B field cause beam energy increases of several MeV

    Hadron beam test of a scintillating fibre tracker system for elastic scattering and luminosity measurement in ATLAS

    Full text link
    A scintillating fibre tracker is proposed to measure elastic proton scattering at very small angles in the ATLAS experiment at CERN. The tracker will be located in so-called Roman Pot units at a distance of 240 m on each side of the ATLAS interaction point. An initial validation of the design choices was achieved in a beam test at DESY in a relatively low energy electron beam and using slow off-the-shelf electronics. Here we report on the results from a second beam test experiment carried out at CERN, where new detector prototypes were tested in a high energy hadron beam, using the first version of the custom designed front-end electronics. The results show an adequate tracking performance under conditions which are similar to the situation at the LHC. In addition, the alignment method using so-called overlap detectors was studied and shown to have the expected precision.Comment: 12 pages, 8 figures. Submitted to Journal of Instrumentation (JINST

    Association of Neuroretinal Thinning and Microvascular Changes with Hypertension in an Older Population in Southern Italy

    Get PDF
    Background: Retinal microvasculature assessment at capillary level may potentially aid the evaluation of early microvascular changes due to hypertension. We aimed to investigate associations between the measures obtained using optical coherence tomography (OCT) and OCT-angiography (OCT-A) and hypertension, in a southern Italian older population. Methods: We performed a crosssectional analysis from a population-based study on 731 participants aged 65 years+ subdivided into two groups according to the presence or absence of blood hypertension without hypertensive retinopathy. The average thickness of the ganglion cell complex (GCC) and the retinal nerve fiber layer (RNFL) were measured. The foveal avascular zone area, vascular density (VD) at the macular site and of the optic nerve head (ONH) and radial peripapillary capillary (RPC) plexi were evaluated. Logistic regression was applied to assess the association of ocular measurements with hypertension. Results: GCC thickness was inversely associated with hypertension (odds ratio (OR): 0.98, 95% confidence interval (CI): 0.97–1). A rarefaction of VD of the ONH plexus at the inferior temporal sector (OR: 0.95, 95% CI: 0.91–0.99) and, conversely, a higher VD of the ONH and RPC plexi inside optic disc (OR: 1.07, 95% CI: 1.04–1.10; OR: 1.04, 95% CI: 1.02–1.06, respectively) were significantly associated with hypertension. Conclusion: A neuroretinal thinning involving GCC and a change in capillary density at the peripapillary network were related to the hypertension in older patients without hypertensive retinopathy. Assessing peripapillary retinal microvasculature using OCT-A may be a useful non-invasive approach to detect early microvascular changes due to hypertension

    Energy Linearity and Resolution of the ATLAS Electromagnetic Barrel Calorimeter in an Electron Test-Beam

    Get PDF
    A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to 245 GeV. The electron beam impinged at one point corresponding to a pseudo-rapidity of eta=0.687 and an azimuthal angle of phi=0.28 in the ATLAS coordinate system. A detailed study of several effects biasing the electron energy measurement allowed an energy reconstruction procedure to be developed that ensures a good linearity and a good resolution. Use is made of detailed Monte Carlo simulations based on Geant which describe the longitudinal and transverse shower profiles as well as the energy distributions. For electron energies between 15 GeV and 180 GeV the deviation of the measured incident electron energy over the beam energy is within 0.1%. The systematic uncertainty of the measurement is about 0.1% at low energies and negligible at high energies. The energy resolution is found to be about 10% sqrt(E) for the sampling term and about 0.2% for the local constant term

    How Have Intravitreal Anti-VEGF and Dexamethasone Implant Been Used in Italy? A Multiregional, Population-Based Study in the Years 2010-2016

    Get PDF
    Purpose: To describe intravitreal anti-VEGF drug and dexamethasone use in four Italian regions.Methods: Four regional claims databases were used to measure drug prevalence, compare dosing intervals to those recommended in the summary of product characteristics (SPC), and identify switchers. Bilateral treatment and diabetic macular edema (DME) coding algorithms were validated, linking claims with a sample of prospectively collected ophthalmological data.Results: Overall, 41,836 patients received 651 study drug in 2010-2016 (4.8 per 10,000 persons). In 2016, anti-VEGF drug use ranged from 0.8 (Basilicata) to 5.7 (Lombardy) per 10,000 persons while intravitreal dexamethasone use ranged from 0.2 (Basilicata) to 1.4 (Lombardy) per 10,000 persons. Overall, 40,815 persons were incident users of study drugs. Among incident users with 651 year of follow-up (N = 30,745), 16.0% (N = 30,745), 16.0% (N = 30,745), 16.0% (.Conclusion: Study drug use increased over time in Lombardy, Basilicata, Calabria, and Sicily, despite a large heterogeneity in prevalence of use across regions. Drug treatment appeared to be partly in line with SPC, suggesting that improvement in clinical practice may be needed to maximize drug benefits

    Position resolution and particle identification with the ATLAS EM calorimeter

    Full text link
    In the years between 2000 and 2002 several pre-series and series modules of the ATLAS EM barrel and end-cap calorimeter were exposed to electron, photon and pion beams. The performance of the calorimeter with respect to its finely segmented first sampling has been studied. The polar angle resolution has been found to be in the range 50-60 mrad/sqrt(E (GeV)). The neutral pion rejection has been measured to be about 3.5 for 90% photon selection efficiency at pT=50 GeV/c. Electron-pion separation studies have indicated that a pion fake rate of (0.07-0.5)% can be achieved while maintaining 90% electron identification efficiency for energies up to 40 GeV.Comment: 32 pages, 22 figures, to be published in NIM
    • …
    corecore