160 research outputs found
Lower variability of radionuclide activities in upland dairy products compared to soils and vegetation: Implication for environmental survey
Contamination of the environment by radionuclides is usually estimated using soil and grass sampling. However, radionuclides are often not homogeneously distributed in soils. In the alpine Mercantour region (Western Alps, France) a large heterogeneity in Chernobyl 137Cs deposition has been previously observed. Here we report additional 137Cs results together with new 90Sr and Pu data for soil, grass, milk, and cheese samples. The results show that radioisotopes from nuclear weapons tests fallout are more homogeneously distributed than Chernobyl 137Cs. Further, we observe that the 137Cs and 90Sr contents are less variable in milk samples than in grass or soil samples. This can be attributed to the homogenization effect of cow vagrancy during grazing. Hence milk seems to be a more robust sample than soil or grass to evaluate the extent of contamination on a regional scale. We explore this idea by comparing own unpublished 90Sr results and 90Sr results from the literature to establish the relationship between altitude of grazing and contamination of soil and milk for Western Europe. There is a significant positive correlation between soil contamination and altitude and an even closer correlation between milk 90Sr activity (A) and altitude (h): A = A0 + ek·h where A0 is the expected activity of milk sampled at sea level (A0 = 0.064 ± 0.014 Bq g-1 Ca) and h is the altitude of grazing, k being a constant (k = 0.95 × 10-3 ± 0.11 × 10-3 m-1 Bq g-1 Ca). The fact that there is less scattering in the relationship for the 90Srmilk-altitude than for 90Srsoil-altitude suggests, again, that milk is a well-suited sample for environmental survey. The relationship between the altitude of grazing and the 90Sr content of milk and cheese can also be used to assess the authenticity of dairy products. © 2006 Elsevier Ltd. All rights reserved
Axial speed of sound is related to tendon's nonlinear elasticity.
PublishedJournal ArticleResearch Support, Non-U.S. Gov'tAxial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness which determines the SOS. The objectives of the present study were to investigate the relationship between axial SOS and tendon's nonlinear elasticity, measured in standard laboratory conditions, and to evaluate if tendon's mass density and cross-sectional area (CSA) affect the SOS level. Axial SOS was measured during in vitro cycling of 9 equine superficial digital tendons. Each tendon's stiffness was characterized with a tangent modulus (the continuous derivative of the true stress/true strain curve) and an elastic modulus (the slope of this curve's linear region). Tendon's SOS was found to linearly vary with the square root of the tangent modulus during loading; tendon's SOS level was found correlated to the elastic modulus's square root and inversely correlated to the tendon's CSA, but it was not affected by tendon's mass density. These results confirm that tendon's tangent and elastic moduli, measured in laboratory conditions, are related to axial SOS and they represent one of its primary determinants.Direction Générale de l’Enseignement et de la Recherche (French Ministry of Agriculture)Région Basse-NormandieInstitut National de la Recherche Agronomiqu
True stress and Poisson's ratio of tendons during loading.
PublishedJournal ArticleResearch Support, Non-U.S. Gov'tExcessive axial tension is very likely involved in the aetiology of tendon lesions, and the most appropriate indicator of tendon stress state is the true stress, the ratio of instantaneous load to instantaneous cross-sectional area (CSA). Difficulties to measure tendon CSA during tension often led to approximate true stress by assuming that CSA is constant during loading (i.e. by the engineering stress) or that tendon is incompressible, implying a Poisson's ratio of 0.5, although these hypotheses have never been tested. The objective of this study was to measure tendon CSA variation during quasi-static tensile loading, in order to assess the true stress to which the tendon is subjected and its Poisson's ratio. Eight equine superficial digital flexor tendons (SDFT, about 30cm long) were tested in tension until failure while the CSA of each tendon was measured in its metacarpal part by means of a linear laser scanner. Axial elongation and load were synchronously recorded during the test. CSA was found to linearly decrease with strain, with a mean decrease at failure of -10.7±2.8% (mean±standard deviation). True stress at failure was 7.1-13.6% higher than engineering stress, while stress estimation under the hypothesis of incompressibility differed from true stress of -6.6 to 2.3%. Average Poisson's ratio was 0.55±0.12 and did not significantly vary with load. From these results on equine SDFT it was demonstrated that tendon in axial quasi-static tension can be considered, at first approximation, as an incompressible material.Direction Générale de l’Enseignement et de la Recherche (French Ministry of Agriculture)Région Basse-NormandieInstitut National de la Recherche Agronomiqu
First application of an axial speed of sound measurement technique in the monitoring of tendon healing
PublishedJournal ArticleN/AInstitut National de la Recherche AgronomiqueRe´gion Basse NormandieDirection Ge´ne´rale de l’Enseignement et de la Recherch
Axial speed of sound for the monitoring of injured equine tendons: a preliminary study.
PublishedJournal ArticleResearch Support, Non-U.S. Gov'tEquine superficial digital flexor tendons (SDFT) are often injured, and they represent an excellent model for human sport tendinopathies. While lesions can be precisely diagnosed by clinical evaluation and ultrasonography, a prognosis is often difficult to establish; the knowledge of the injured tendon's mechanical properties would help in anticipating the outcome. The objectives of the present study were to compare the axial speed of sound (SOS) measured in vivo in normal and injured tendons and to investigate their relationship with the tendons' mechanical parameters, in order to assess the potential of quantitative axial ultrasound to monitor the healing of the injured tendons. SOS was measured in vivo in the right fore SDFTs of 12 horses during walk, before and 3.5 months after the surgical induction of a bilateral core lesion. The 12 horses were then euthanized, their SDFTs isolated and tested in tension to measure their elastic modulus and maximal load (and corresponding stress). SOS significantly decreased from 2179.4 ± 31.4 m/s in normal tendons to 2065.8 ± 67.1 m/s 3.5 months after the surgical induction, and the tendons' elastic modulus (0.90 ± 0.17 GPa) was found lower than what has been reported in normal tendons. While SOS was not correlated to tendon maximal load and corresponding stress, the SOS normalized on its value in normal tendons was correlated to the tendons' elastic modulus. These preliminary results confirm the potential of axial SOS in helping the functional assessment of injured tendon.Direction Générale de l’Enseignement et de la Recherche (French Ministry of Agriculture)Région Basse-NormandieInstitut National de la Recherche AgronomiqueAgence Nationale de la Recherch
The effect of induced forelimb lameness on thoracolumbar kinematics during treadmill locomotion
Reasons for performing study: Lameness has often been suggested to result in altered movement of the back, but there are no detailed studies describing such a relationship in quantitative terms. Objectives: To quantify the effect of induced subtle forelimb lameness on thoracolumbar kinematics in the horse. Methods: Kinematics of 6 riding horses was measured at walk and at trot on a treadmill before and after the induction of reversible forelimb lameness grade 2 (AAEP scale 1-5). Ground reaction forces (GRF) for individual limbs were calculated from kinematics. Results: The horses significantly unloaded the painful limb by 11.5% at trot, while unloading at walk was not significant. The overall flexion-extension range of back motion decreased on average by 0.2° at walk and increased by 3.3° at trot (P<0.05). Changes in angular motion patterns of vertebral joints were noted only at trot, with an increase in flexion of 0.9° at T10 (i.e. angle between T6, T10 and T13) during the stance phase of the sound diagonal and an increase in extension of the thoracolumbar area during stance of the lame diagonal (0.7° at T13, 0.8° at T17, 0.5° at L1, 0.4° at L3 and 0.3° at L5) (P<0.05). Lameness further caused a lateral bending of the cranial thoracic vertebral column towards the lame side (1.3° at T10 and 0.9° at T13) (P<0.05) during stance of the lame diagonal. Conclusions: Both range of motion and vertebral angular motion patterns are affected by subtle forelimb lameness. At walk, the effect is minimal, at trot the horses increased the vertebral range of motion and changed the pattern of thoracolumbar motion in the sagittal and horizontal planes, presumably in an attempt to move the centre of gravity away from the lame side and reduce the force on the affected limb. Potential relevance: Subtle forelimb lameness affects thoracolumbar kinematics. Future studies should aim at elucidating whether the altered movement patterns lead to back and/or neck dysfunction in the case of chronic lameness
Hydrological Behaviour of Tritium on the Former Semipalatinsk Nuclear Test Site (Kazakhstan) Determined using Stable Isotope Measurements
Tritium and stable isotope (deuterium 2H and 18O) concentrations have been determined in natural waters
collected from shallow lakes, wells, streams and rivers inside and in the vicinity of the former Semipalatinsk
Nuclear Test Site (NE Kazakhstan). The Semipalatinsk Test Site (STS) was one of the main proving grounds
for the testing of nuclear weapons by the former Soviet Union. Tritium activity concentrations have been
determined by liquid scintillation counting, while hydrogen isotopic composition have been determined
using a GV-Isoprime mass spectrometer coupled to an elemental analyzer. Tritium activity concentrations
recorded in lake waters (in most cases >10 Bq L-1) were significantly higher than those in well, stream and
the Irtysh River waters. In lake waters, enrichments in deuterium and 18O (δD and δ18O varying between –5
and –64 ‰ V-SMOW and –8.4 and +5.5 ‰ V-SMOW, respectively), and high salt concentrations, strongly
suggest that significant evaporation has occurred. In contrast, deuterium and tritium signatures of ‘common’
surface and underground waters at the STS were mostly typical of present-day isotope backgrounds of natural waters in NE Kazakhstan. In STS, come salt lakes like Bajansor and Tumatsor with elevated tritium activity from 12 to 15 Bq L-1 lie close to the Global Meteoric Water Line. The potential tritium source for these lakes is residual concentration of tritium after former nuclear test in STS. The study provides evidence to show that export of tritium from underground nuclear test areas and tritium enrichment produced by evaporation are both important determinants of tritium concentrations in standing waters on the Semipalatinsk test site
First light of VLT/HiRISE: High-resolution spectroscopy of young giant exoplanets
A major endeavor of this decade is the direct characterization of young giant exoplanets at high spectral resolution to determine the composition of their atmosphere and infer their formation processes and evolution. Such a goal represents a major challenge owing to their small angular separation and luminosity contrast with respect to their parent stars. Instead of designing and implementing completely new facilities, it has been proposed to leverage the capabilities of existing instruments that offer either high-contrast imaging or high-dispersion spectroscopy by coupling them using optical fibers. In this work, we present the implementation and first on-sky results of the High-Resolution Imaging and Spectroscopy of Exoplanets (HiRISE) instrument at the Very Large Telescope (VLT), which combines the exoplanet imager SPHERE with the recently upgraded high-resolution spectrograph CRIRES using single-mode fibers. The goal of HiRISE is to enable the characterization of known companions in the H band at a spectral resolution on the order of R = λ/∆λ = 100 000 in a few hours of observing time. We present the main design choices and the technical implementation of the system, which is constituted of three major parts: the fiber injection module inside of SPHERE, the fiber bundle around the telescope, and the fiber extraction module at the entrance of CRIRES. We also detail the specific calibrations required for HiRISE and the operations of the instrument for science observations. Finally, we detail the performance of the system in terms of astrometry, temporal stability, optical aberrations, and transmission, for which we report a peak value of ~3.9% based on sky measurements in median observing conditions. Finally, we report on the first astrophysical detection of HiRISE to illustrate its potential
First light of VLT/HiRISE: High-resolution spectroscopy of young giant exoplanets
A major endeavor of this decade is the direct characterization of young giant
exoplanets at high spectral resolution to determine the composition of their
atmosphere and infer their formation processes and evolution. Such a goal
represents a major challenge owing to their small angular separation and
luminosity contrast with respect to their parent stars. Instead of designing
and implementing completely new facilities, it has been proposed to leverage
the capabilities of existing instruments that offer either high contrast
imaging or high dispersion spectroscopy, by coupling them using optical fibers.
In this work we present the implementation and first on-sky results of the
HiRISE instrument at the very large telescope (VLT), which combines the
exoplanet imager SPHERE with the recently upgraded high resolution spectrograph
CRIRES using single-mode fibers. The goal of HiRISE is to enable the
characterization of known companions in the band, at a spectral resolution
of the order of , in a few hours of
observing time. We present the main design choices and the technical
implementation of the system, which is constituted of three major parts: the
fiber injection module inside of SPHERE, the fiber bundle around the telescope,
and the fiber extraction module at the entrance of CRIRES. We also detail the
specific calibrations required for HiRISE and the operations of the instrument
for science observations. Finally, we detail the performance of the system in
terms of astrometry, temporal stability, optical aberrations, and transmission,
for which we report a peak value of 3.9% based on sky measurements in
median observing conditions. Finally, we report on the first astrophysical
detection of HiRISE to illustrate its potential.Comment: 17 pages, 15 figures, 3 tables. Submitted to A&A on 19 September 202
- …