1,542 research outputs found

    From satisfaction to expectation: The patient's perspective in lower limb prosthetic care

    Get PDF
    Neck pain is a common musculoskeletal complaint and a relationship with reduced work-related functional capacity is assumed. A validated instrument to test functional capacity of patients with neck pain is unavailable. The objective of this study was to develop a Functional Capacity Evaluation (FCE), which is content valid for determining functional capacity in patients with work related neck disorders (WRND). A review of epidemiological review literature was conducted to identify physical risk factors for WRND. Evidence was found that physical risk factors contribute in development of WRND. Physical risk factors were related to repetitive movements, forceful movements, awkward positions and static contractions of the neck or the neck/shoulder region. An FCE was designed based on the risk factors identified. Eight tests were selected to cover all risk factors: repetitive side reaching, repetitive reaching overhead, static overhead work, front carry, forward static bend neck, overhead lift and the neck strength test. Content validity of this FCE was established by providing the rationale, specific objectives and operational definitions of the FCE. Further research is needed to establish reliability and other aspects of validity of the neck-FCE Aim Worldwide, family- centred and co- ordinated care are seen as the two most desirable and effective methods of paediatric care delivery. This study outlines current views on how team collaboration comprising professionals in paediatric rehabilitation and special education and the parents of children with disabilities should be organized, and analyses the policies of five paediatric rehabilitation settings associated with the care of 44 children with cerebral palsy ( CP) in the Netherlands. Methods For an overview of current ideas on collaboration, written statements of professional associations in Dutch paediatric rehabilitation were examined. The policy statements of the five participating settings were derived from their institutional files. Documents detailing the collaborative arrangements involving the various professionals and parents were evaluated at the institutional level and at the child level. Involvement of the stakeholders was analysed based on team conferences. Results Also in the Netherlands collaboration between rehabilitation and education professionals and parents is endorsed as the key principle in paediatric rehabilitation, with at its core the team conference in which the various priorities and goals are formulated and integrated into a personalized treatment plan. As to their collaborative approaches between rehabilitation centre and school, the five paediatric settings rarely differed, but at the child level approaches varied. Teams were large ( averaging 10.5 members), and all three stakeholder groups were represented, but involvement differed per setting, as did the roles and contributions of the individual team members. Conclusion Collaboration between rehabilitation and education professionals and parents is supported and encouraged nationwide. Views on collaboration have been formulated, and general guidelines on family- centred and co- ordinated care are available. Yet, collaborative practices in Dutch paediatric care are still developing. Protocols that carefully delineate the commitments to collaborate and that translate the policies into practical, detailed guidelines are needed, as they are a prerequisite for successful teamwork

    One pot ‘click’ reactions: tandem enantioselective biocatalytic epoxide ring opening and [3+2] azide alkyne cycloaddition

    Get PDF
    Halohydrin dehalogenase (HheC) can perform enantioselective azidolysis of aromatic epoxides to 1,2-azido alcohols which are subsequently ligated to alkynes producing chiral hydroxy triazoles in a one-pot procedure with excellent enantiomeric excess.

    Uphill and downhill walking in unilateral lower limb amputees

    Get PDF
    Objective: To study adjustment strategies in unilateral amputees in uphill and downhill walking. Design: observational cohort study. Subjects: Seven transfemoral, 12 transtibial unilateral amputees and 10 able-bodied subjects. Methods: In a motion analysis laboratory the subjects walked over a level surface and an uphill and downhill slope. Gait velocity and lower limb joint angles were measured. Results: In uphill walking hip and knee flexion at initial contact and hip flexion in swing were increased in the prosthetic limb of transtibial amputees. In downhill walking transtibial amputees showed more knee flexion on the prosthetic side in late stance and swing. Transfemoral amputees were not able to increase prosthetic knee flexion in uphill and downhill walking. An important adjustment strategy in both amputee Groups was a smaller hip extension in late stance in uphill and downhill walking, probably related with a shorter step length. In addition, amputees increased knee flexion in early stance in the non-affected limb in uphill walking to compensate for the shorter prosthetic limb length. In downhill walking fewer adjustments were necessary, since the shorter prosthetic limb already resulted in lowering of the body. Conclusion: Uphill and downhill walking can be trained in rehabilitation, which may improve safety and confidence of amputees. Prosthetic design should focus on better control of prosthetic knee flexion abilities without reducing stability. (c) 2007 Elsevier B.V. All fights reserved

    Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    Get PDF
    At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\eta| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.Comment: 7 pages, 25 figures, submitted for publication in conference record of the 2011 IEEE Nuclear Science Symposium, Valencia, Spai

    Abnormal ECG Findings in Athletes: Clinical Evaluation and Considerations.

    Get PDF
    PURPOSE OF REVIEW: Pre-participation cardiovascular evaluation with electrocardiography is normal practice for most sporting bodies. Awareness about sudden cardiac death in athletes and recognizing how screening can help identify vulnerable athletes have empowered different sporting disciplines to invest in the wellbeing of their athletes. RECENT FINDINGS: Discerning physiological electrical alterations due to athletic training from those representing cardiac pathology may be challenging. The mode of investigation of affected athletes is dependent on the electrical anomaly and the disease(s) in question. This review will highlight specific pathological ECG patterns that warrant assessment and surveillance, together with an in-depth review of the recommended algorithm for evaluation

    Formation of the ηc\eta_c in Two-Photon Collisions at LEP

    Full text link
    The two-photon width Γγγ\Gamma_{\gamma\gamma} of the ηc\eta_c meson has been measured with the L3 detector at LEP. The ηc\eta_c is studied in the decay modes π+ππ+π\pi^+\pi^-\pi^+\pi^-, π+π\pi^+\pi^-K+^+K^-, Ks0_s^0K±π^\pm\pi^\mp, K+^+Kπ0^-\pi^{0}, π+πη\pi^+\pi^-\eta, π+πη\pi^+\pi^-\eta', and ρ+ρ\rho^+\rho^- using an integrated luminosity of 140 pb1^{-1} at s91\sqrt{s} \simeq 91 GeV and of 52 pb1^{-1} at s183\sqrt{s} \simeq 183 GeV. The result is Γγγ(ηc)=6.9±1.7(stat.)±0.8(sys.)±2.0\Gamma_{\gamma\gamma}(\eta_c) = 6.9 \pm 1.7 (stat.) \pm 0.8 (sys.) \pm 2.0(BR) keV. The Q2Q^2 dependence of the ηc\eta_c cross section is studied for Q2<9Q^2 < 9 GeV2^{2}. It is found to be better described by a Vector Meson Dominance model form factor with a J-pole than with a ρ\rho-pole. In addition, a signal of 29±1129 \pm 11 events is observed at the χc0\chi_c0 mass. Upper limits for the two-photon widths of the χc0\chi_c0, χc2\chi_c2, and ηc\eta_c' are also given

    A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

    Full text link
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste, Italy). arXiv admin note: text overlap with arXiv:1512.0848

    Search for Charginos with a Small Mass Difference with the Lightest Supersymmetric Particle at \sqrt{s} = 189 GeV

    Get PDF
    A search for charginos nearly mass-degenerate with the lightest supersymmetric particle is performed using the 176 pb^-1 of data collected at 189 GeV in 1998 with the L3 detector. Mass differences between the chargino and the lightest supersymmetric particle below 4 GeV are considered. The presence of a high transverse momentum photon is required to single out the signal from the photon-photon interaction background. No evidence for charginos is found and upper limits on the cross section for chargino pair production are set. For the first time, in the case of heavy scalar leptons, chargino mass limits are obtained for any \tilde{\chi}^{+-}_1 - \tilde{\chi}^0_1 mass difference

    Measurement of Hadron and Lepton-Pair Production at 130GeV < \sqrt{s} < 189 GeV at LEP

    Full text link
    We report on measurements of e+e- annihilation into hadrons and lepton pairs. The data have been collected with the L3 detector at LEP at centre-of-mass energies between 130 and 189 GeV. Using a total integrated luminosity of 243.7 pb^-1, 25864 hadronic and 8573 lepton-pair events are selected for the measurement of cross sections and leptonic forward-backward asymmetries. The results are in good agreement with Standard Model predictions

    Search for antihelium in cosmic rays

    Get PDF
    The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle Discovery during flight STS-91 in a 51.7 degree orbit at altitudes between 320 and 390 km. A total of 2.86 * 10^6 helium nuclei were observed in the rigidity range 1 to 140 GV. No antihelium nuclei were detected at any rigidity. An upper limit on the flux ratio of antihelium to helium of < 1.1 * 10^-6 is obtained.Comment: 18 pages, Latex, 9 .eps figure
    corecore