112 research outputs found

    Does sensory relearning improve tactile function after carpal tunnel decompression? A pragmatic, assessor-blinded, randomized clinical trial

    Get PDF
    Despite surgery for carpal tunnel syndrome (CTS) being effective in 80-90% of cases, chronic numbness and hand disability can occur. The aim of this study was to investigate whether sensory relearning improves tactile discrimination and hand function after decompression. In a multi-centre, pragmatic, randomized, controlled trial, 104 patients were randomized to sensory relearning (n=52) or control (n=52) group. 93 patients completed 12 week follow-up. Primary outcome was the Shape-Texture Identification (STI) test at 6 weeks. Secondary outcomes were touch threshold, touch localisation, dexterity and self-reported hand function. No significant group differences were seen for the primary outcome (STI) at 6 weeks or 12 weeks. Similarly, no significant group differences were observed on secondary outcomes, with the exception of self-reported hand function. A secondary Complier-Averaged-CausalEffects (CACE) analysis showed no statistically significant treatment effect on the primary outcome. Sensory relearning for tactile sensory and functional deficits after carpal tunnel decompression is not effective

    The Harris hip score: Do ceiling effects limit its usefulness in orthopedics?: A systematic review

    Get PDF
    The Harris hip score (HHS), a disease-specific health status scale that is frequently used to measure the outcome of total hip arthroplasty, has never been validated properly. A questionnaire is suitable only when all 5 psychometric properties are of sufficient quality. We questioned the usefulness of the HHS by investigating its content validity. We performed a systematic review based on a literature search in PubMed, Embase, and the Cochrane Library for descriptive studies published in 2007. 54 studies (59 patient groups) met our criteria and were included in the data analysis. To determine the content validity, we calculated the ceiling effect (percentage) for each separate study and we pooled data to measure the weighted mean. A subanalysis of indications for THA was performed to differentiate the populations for which the HHS would be suitable and for which it would not. A ceiling effect of 15% or less was considered to be acceptable. Over half the studies (31/59) revealed unacceptable ceiling effects. Pooled data across the studies included (n = 6,667 patients) suggested ceiling effects of 20% (95%CI: 18-22). Ceiling effects were greater (32%, 95%CI:12-52) in those patients undergoing hip resurfacing arthroplasty. Although the Harris hip score is widely used in arthroplasty research on outcomes, ceiling effects are common and these severely limit its validity in this field of researc

    Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Get PDF
    <p>Abstract</p> <p><b>Background</b></p> <p>Patients undergoing total knee arthroplasty (TKA) often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD) in measuring isometric knee strength in patients awaiting TKA.</p> <p><b>Methods</b></p> <p>To determine interrater reliability, 32 patients (81.3% female) were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13) was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC). In addition, the Standard Error of Measurement (SEM) and the Smallest Detectable Difference (SDD) were used to determine reliability.</p> <p><b>Results</b></p> <p>In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94) and excellent for knee extensors (ICC range 0.92-0.97). However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors.</p> <p><b>Conclusions</b></p> <p>Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to evaluate knee strength changes in TKA patient groups. However, it also demonstrates that modified HHD is not suitable to measure individual strength changes. The use of modified HHD is, therefore, not advised for use in a clinical setting.</p

    Functional recovery is considered the most important target: a survey of dedicated professionals

    Get PDF
    Background: The aim of this study was to survey the relative importance of postoperative recovery targets and perioperative care items, as perceived by a large group of international dedicated professionals. Methods: A questionnaire with eight postoperative recovery targets and 13 perioperative care items was mailed to participants of the first international Enhanced Recovery After Surgery (ERAS) congress and to authors of papers with a clear relevance to ERAS in abdominal surgery. The responders were divided into categories according to profession and region. Results: The recovery targets ‘To be completely free of nausea’, ‘To be independently mobile’ and ‘To be able to eat and drink as soon as possible’ received the highest score irrespective of the responder's profession or region of origin. Equally, the care items ‘Optimizing fluid balance’, ‘Preoperative counselling’ and ‘Promoting early and scheduled mobilisation’ received the highest score across all groups. Conclusions: Functional recovery, as in tolerance of food without nausea and regained mobility, was considered the most important target of recovery. There was a consistent uniformity in the way international dedicated professionals scored the relative importance of recovery targets and care items. The relative rating of the perioperative care items was not dependent on the strength of evidence supporting the items

    Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components? A systematic review of the literature

    Get PDF
    Joint arthroplasty registries show an increased rate of aseptic loosening in uncemented acetabular components as compared to cemented acetabular components. Since loosening is associated with particulate wear debris, we postulated that uncemented acetabular components demonstrate a higher polyethylene wear rate than cemented acetabular components in total hip arthroplasty. We performed a systematic review of the peer-reviewed literature, comparing the wear rate in uncemented and cemented acetabular components in total hip arthroplasty. Studies were identified using MEDLINE (PubMed), EMBASE and the Cochrane Central Register of Controlled Trials. Study quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. The search resulted in 425 papers. After excluding duplicates and selection based on title and abstracts, nine studies were found eligible for further analysis: two randomised controlled trials, and seven observational studies. One randomised controlled trial found a higher polyethylene wear rate in uncemented acetabular components, while the other found no differences. Three out of seven observational studies showed a higher polyethylene wear in uncemented acetabular component fixation; the other four studies did not show any differences in wear rates. The available evidence suggests that a higher annual wear rate may be encountered in uncemented acetabular components as compared to cemented components
    corecore