1,540 research outputs found

    CdWO4 scintillating bolometer for Double Beta Decay: Light and Heat anticorrelation, light yield and quenching factors

    Full text link
    We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different interacting particles aiming at the disentanglement and the reduction of background contribution, key issue for next generation experiments. We will describe the observed anticorrelation between the heat and the light signal and we will show how this feature can be used in order to increase the energy resolution of the bolometer over the entire energy spectrum, improving up to a factor 2.6 on the 2615 keV line of 208Tl. The detector was tested in a 433 h background measurement that permitted to estimate extremely low internal trace contaminations of 232Th and 238U. The light yield of gamma/beta, alpha and neutrons is presented. Furthermore we developed a method in order to correctly evaluate the absolute thermal quenching factor of alpha particles in scintillating bolometers.Comment: 8 pages 7 figure

    An innovative technique for the investigation of the 4-fold forbidden beta-decay of 50^{50}V

    Full text link
    For the first time a Vanadium-based crystal was operated as cryogenic particle detector. The scintillating low temperature calorimetric technique was used for the characterization of a 22 g YVO4_4 crystal aiming at the investigation of the 4-fold forbidden non-unique β\beta^- decay of 50^{50}V. The excellent bolometric performance of the compound together with high light output of the crystal makes it an outstanding technique for the study of such elusive rate process. The internal radioactive contaminations of the crystal are also investigated showing that an improvement on the current status of material selection and purification are needed, 235/238^{235/238}U and 232^{232}Th are measured at the level of 28 mBq/kg, 1.3 Bq/kg and 28 mBq/kg, respectively. In this work, we also discuss a future upgrade of the experimental set-up which may pave the road for the detection of the rare 50^{50}V β\beta^- decay

    Scintillating double beta decay bolometers

    Full text link
    We present the results obtained in the development of scintillating Double Beta Decay bolometers. Several Mo and Cd based crystals were tested with the bolometric technique. The scintillation light was measured through a second independent bolometer. A 140 g CdWO_4 crystal was run in a 417 h live time measurement. Thanks to the scintillation light, the alpha background is easily discriminated resulting in zero counts above the 2615 keV gamma line of Thallium 208. These results, combined with an extremely easy light detector operation, represent the first tangible proof demonstrating the feasibility of this kind of technique.Comment: 15 pages, 8 figure

    ZnMoO4: a promising bolometer for neutrinoless double beta decay searches

    Full text link
    We investigate the performances of two ZnMoO4 scintillating crystals operated as bolometers, in view of a next generation experiment to search the neutrinoless double beta decay of Mo-100. We present the results of the alpha vs beta/gamma discrimination, obtained through the scintillation light as well as through the study of the shape of the thermal signal alone. The discrimination capability obtained at the 2615 keV line of Tl-208 is 8 sigma, using the heat-light scatter plot, while it exceeds 20 sigma using the shape of the thermal pulse alone. The achieved FWHM energy resolution ranges from 2.4 keV (at 238 keV) to 5.7 keV (at 2615 keV). The internal radioactive contaminations of the ZnMoO4 crystals were evaluated through a 407 hours background measurement. The obtained limit is < 32 microBq/kg for Th-228 and Ra-226. These values were used for a Monte Carlo simulation aimed at evaluating the achievable background level of a possible, future array of enriched ZnMoO4 crystals.Comment: 9 pages, 8 figure

    Two types of all-optical magnetization switching mechanisms using femtosecond laser pulses

    Full text link
    Magnetization manipulation in the absence of an external magnetic field is a topic of great interest, since many novel physical phenomena need to be understood and promising new applications can be imagined. Cutting-edge experiments have shown the capability to switch the magnetization of magnetic thin films using ultrashort polarized laser pulses. In 2007, it was first observed that the magnetization switching for GdFeCo alloy thin films was helicity-dependent and later helicity-independent switching was also demonstrated on the same material. Recently, all-optical switching has also been discovered for a much larger variety of magnetic materials (ferrimagnetic, ferromagnetic films and granular nanostructures), where the theoretical models explaining the switching in GdFeCo films do not appear to apply, thus questioning the uniqueness of the microscopic origin of all-optical switching. Here, we show that two different all-optical switching mechanisms can be distinguished; a "single pulse" switching and a "cumulative" switching process whose rich microscopic origin is discussed. We demonstrate that the latter is a two-step mechanism; a heat-driven demagnetization followed by a helicity-dependent remagnetization. This is achieved by an all-electrical and time-dependent investigation of the all-optical switching in ferrimagnetic and ferromagnetic Hall crosses via the anomalous Hall effect, enabling to probe the all-optical switching on different timescales.Comment: 1 page, LaTeX; classified reference number

    Complete elimination of 1K Pot vibrations in dilution refrigerators

    Get PDF
    Cryogenic vibrations generated by continuously filled 1K Pots are a well known source of noise in all cryogenic experiments using dilution refrigerators. Starting from recent developments we realized a non invasive modification to the cryostat that completely eliminated vibrations, thermalizing the helium coming from the main bath at the pot temperature. We describe the new experimental setup and complete study of the phenomena

    Cryogenic light detectors with enhanced performance for rare events physics

    Full text link
    We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward mounting results in three important improvements: (1) it decreases the amount of non-active materials needed to assemble the detector, (2) it substantially increases the light collection efficiency by minimizing the light losses induced by the mounting structure, and (3) it enhances the thermal signal induced in the light detector thanks to the extremely weak thermal link to the thermal bath. We tested this new technique with a 16 cm2^2 Ge light detector with thermistor readout sitting on the surface of a large TeO2_2 bolometer. The light collection efficiency was increased by greater than 50\% compared to previously tested alternative mountings. We obtained a baseline energy resolution on the light detector of 20~eV RMS that, together with increased light collection, enabled us to obtain the best α\alpha vs β/γ\beta/\gamma discrimination ever obtained with massive TeO2_2 crystals. At the same time we achieved rise and decay times of 0.8 and 1.6 ms, respectively. This superb performance meets all of the requirements for the CUPID (CUORE Upgrade with Particle IDentification) experiment, which is a 1-ton scintillating bolometer follow up to CUORE.Comment: 6 pages, 4 figure

    Characterization of ZnSe scintillating bolometers for Double Beta Decay

    Full text link
    ZnSe scintillating bolometers are good candidates for future Double Beta Decay searches, because of the 82Se high Q-value and thanks to the possibility of alpha background rejection on the basis of the scintillation signal. In this paper we report the characteristics and the anomalies observed in an extensive study of these devices. Among them, an unexpected high emission from alpha particles, accompanied with an unusual pattern of the light vs. heat scatter plot. The perspectives for the application of this kind of detectors to search for the Neutrinoless Double Beta Decay of 82Se are presented.Comment: 12 pages, 10 figure
    corecore