98 research outputs found

    Continuum of vasodilator stress from rest to contrast medium to adenosine hyperemia for fractional flow reserve assessment

    Get PDF
    Objectives: This study compared the diagnostic performance with adenosine-derived fractional flow reserve (FFR) ≤0.8 of contrast-based FFR (cFFR), resting distal pressure (Pd)/aortic pressure (Pa), and the instantaneous wave-free ratio (iFR). Background: FFR objectively identifies lesions that benefit from medical therapy versus revascularization. However, FFR requires maximal vasodilation, usually achieved with adenosine. Radiographic contrast injection causes submaximal coronary hyperemia. Therefore, intracoronary contrast could provide an easy and inexpensive tool for predicting FFR. Methods: We recruited patients undergoing routine FFR assessment and made paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, cFFR, and FFR). Contrast medium and dose were per local practice, as was the dose of intracoronary adenosine. Operators were encouraged to perform both intracoronary and intravenous adenosine assessments and a final drift check to assess wire calibration. A central core lab analyzed blinded pressure tracings in a standardized fashion. Results: A total of 763 subjects were enrolled from 12 international centers. Contrast volume was 8 ± 2 ml per measurement, and 8 different contrast media were used. Repeated measurements of each metric showed a bias <0.005, but a lower SD (less variability) for cFFR than resting indexes. Although Pd/Pa and iFR demonstrated equivalent performance against FFR ≤0.8 (78.5% vs. 79.9% accuracy; p = 0.78; area under the receiver-operating characteristic curve: 0.875 vs. 0.881; p = 0.35), cFFR improved both metrics (85.8% accuracy and 0.930 area; p < 0.001 for each) with an optimal binary threshold of 0.83. A hybrid decision-making strategy using cFFR required adenosine less often than when based on either Pd/Pa or iFR. Conclusions: cFFR provides diagnostic performance superior to that of Pd/Pa or iFR for predicting FFR. For clinical scenarios or health care systems in which adenosine is contraindicated or prohibitively expensive, cFFR offers a universal technique to simplify invasive coronary physiological assessments. Yet FFR remains the reference standard for diagnostic certainty as even cFFR reached only ∼85% agreement

    Recovery of Absolute Coronary Blood Flow and Microvascular Resistance After Chronic Total Occlusion Percutaneous Coronary Intervention: An Exploratory Study

    Get PDF
    Background: This study aimed to investigate longitudinal physiological changes in the recanalized coronary chronic total occlusion (CTO) vessel and its dependent myocardium after successful percutaneous coronary intervention (PCI). Methods and Results: In this pilot study, 25 patients scheduled for elective CTO PCI with viable myocardium and angiographically visible collaterals were included. Absolute coronary blood flow and absolute microvascular resistance were measured invasively using continuous thermodilution. Measurements were performed immediately after successful CTO PCI and at short‐term follow‐up. In a subgroup of patients, physiological measurements were performed at the predominant donor vessel before CTO PCI, immediately afterwards, and at follow‐up. Absolute coronary blood flow in the recanalized CTO artery increased from 148±53 mL/min immediately after PCI to 221±77 mL/min at follow‐up (P<0.001). In agreement, absolute resistance in the myocardial territory perfused by the CTO artery, decreased from 545±255 Wood units immediately after the procedure to 387±128 Wood units at follow‐up (P=0.014). There were no significant changes in the absolute coronary blood flow and resistance in the predominant donor between baseline and follow‐up. Positive remodeling of the distal CTO vessel with an increase in lumen diameter was observed. Conclusions: After successful CTO PCI, blood flow in the recanalized artery and microvascular function of the dependent myocardium are not immediately normal but recover over time

    Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME): 5-year follow-up of a randomised controlled trial

    Get PDF
    In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study was to investigate whether the favourable clinical outcome with the FFR-guided PCI in the FAME study persisted over a 5-year follow-up

    Agreement of the resting distal to aortic coronary pressure with the instantaneous wave-free ratio

    Get PDF
    Background: Recently, 2 randomized controlled trials showed that the instantaneous wave-free ratio (iFR), a resting coronary physiological index, is noninferior to fractional flow reserve for guiding revascularization. The resting distal to aortic coronary pressure (Pd/Pa) measured at rest is another adenosine-free index widely available in the cardiac catheterization laboratory; however, little is known about the agreement of Pd/Pa using iFR as a reference standard. Objectives: The goal of this study was to investigate the agreement of Pd/Pa with iFR. Methods: A total of 763 patients were prospectively enrolled from 12 institutions. iFR and Pd/Pa were measured under resting conditions. Using iFR ≤0.89 as a reference standard, the agreement of Pd/Pa and its best cutoff value were assessed. Results: According to the independent core laboratory analysis, iFR and Pd/Pa were analyzable in 627 and 733 patients (82.2% vs. 96.1%; p &lt; 0.001), respectively. The median iFR and Pd/Pa were 0.90 (interquartile range: 0.85 to 0.94) and 0.92 (interquartile range: 0.88 to 0.95), and the 2 indices were highly correlated (R2 = 0.93; p &lt; 0.001; iFR = 1.31 * Pd/Pa –0.31). According to the receiver-operating characteristic curve analysis, Pd/Pa showed excellent agreement (area under the curve: 0.98; 95% confidence interval: 0.97 to 0.99; p &lt; 0.001) with a best cutoff value of Pd/Pa ≤0.91. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 93.0%, 91.4%, 94.4%, 93.3%, and 92.7%, respectively. These results were similar in patients with acute coronary syndrome and stable angina. Conclusions: Pd/Pa was analyzable in a significantly higher number of patients than iFR. Pd/Pa showed excellent agreement with iFR, suggesting that it could be applied clinically in a similar fashion. (Can Contrast Injection Better Approximate FFR Compared to Pure Resting Physiology? [CONTRAST]; NCT02184117)

    Increased platelet reactivity is associated with circulating platelet-monocyte complexes and macrophages in human atherosclerotic plaques

    Get PDF
    Objective: Platelet reactivity, platelet binding to monocytes and monocyte infiltration play a detrimental role in atherosclerotic plaque progression. We investigated whether platelet reactivity was associated with levels of circulating platelet-monocyte complexes (PMCs) and macrophages in human atherosclerotic carotid plaques. Methods: Platelet reactivity was determined by measuring platelet P-selectin expression after platelet stimulation with increasing concentrations of adenosine diphosphate (ADP), in two independent cohorts: the Circulating Cells cohort (n = 244) and the Athero-Express cohort (n = 91). Levels of PMCs were assessed by flow cytometry in blood samples of patients who were scheduled for percutaneous coronary intervention (Circulating Cells cohort). Monocyte infiltration was semi-quantitatively determined by histological examination of atherosclerotic carotid plaques collected during carotid endarterectomy (Athero-Express cohort). Results: We found increased platelet reactivity in patients with high PMCs as compared to patients with low PMCs (median (interquartile range): 4153 (1585-11267) area under the curve (AUC) vs. 9633 (3580-21565) AUC, P<0.001). Also, we observed increased pl

    Coronary microvascular resistance: methods for its quantification in humans

    Get PDF
    Coronary microvascular dysfunction is a topic that has recently gained considerable interest in the medical community owing to the growing awareness that microvascular dysfunction occurs in a number of myocardial disease states and has important prognostic implications. With this growing awareness, comes the desire to accurately assess the functional capacity of the coronary microcirculation for diagnostic purposes as well as to monitor the effects of therapeutic interventions that are targeted at reversing the extent of coronary microvascular dysfunction. Measurements of coronary microvascular resistance play a pivotal role in achieving that goal and several invasive and noninvasive methods have been developed for its quantification. This review is intended to provide an update pertaining to the methodology of these different imaging techniques, including the discussion of their strengths and weaknesses

    Assessment of the collateral circulation of the heart

    No full text

    Reply

    No full text
    corecore