64 research outputs found

    Nonvalidated home blood pressure devices dominate the online marketplace in Australia: major implications for cardiovascular risk management

    Get PDF
    Self-home blood pressure (BP) monitoring is recommended to guide clinical decisions on hypertension and is used worldwide for cardiovascular risk management. People usually make their own decisions when purchasing BP devices, which can be made online. If patients purchase nonvalidated devices (those not proven accurate according to internationally accepted standards), hypertension management may be based on inaccurate readings resulting in under- or over-diagnosis or treatment. This study aimed to evaluate the number, type, percentage validated, and cost of home BP devices available online. A search of online businesses selling devices for home BP monitoring was conducted. Multinational companies make worldwide deliveries, so searches were restricted to BP devices available for one nation (Australia) as an example of device availability through the global online marketplace. Validation status of BP devices was determined according to established protocols. Fifty nine online businesses, selling 972 unique BP devices were identified. These included 278 upper-arm cuff devices (18.3% validated), 162 wrist-cuff devices (8.0% validated), and 532 wrist-band wearables (0% validated). Most BP devices (92.4%) were stocked by international e-commerce businesses (eg, eBay, Amazon), but only 5.5% were validated. Validated cuff BP devices were more expensive than nonvalidated devices: median (interquartile range) of 101.1 (75.0–151.5) versus 67.4 (30.4–112.8) Australian Dollars. Nonvalidated BP devices dominate the online marketplace and are sold at lower cost than validated ones, which is a major barrier to accurate home BP monitoring and cardiovascular risk management. Before purchasing a BP device, people should check it has been validated at https://www.stridebp.org

    Brachial-cuff excess pressure is associated with carotid intima-media thickness among Australian children: a cross-sectional population study

    Get PDF
    Reservoir pressure parameters (i.e., reservoir pressure [RP] and excess pressure [XSP]) independently predict cardiovascular events in adults, but this has not been investigated in children. This study aimed to determine (1) the association of reservoir pressure parameters with carotid intima-media thickness (carotid IMT), a preclinical vascular phenotype, and (2) whether a multivariable regression model with or without reservoir pressure parameters fits better for estimating carotid IMT in children. Study participants were 11–12-year-old children (n = 1231, 50% male) from the Child Health CheckPoint study, a cross-sectional substudy of the population-based Longitudinal Study of Australian Children. RP and XSP were obtained using brachial-cuff oscillometry (SphygmoCor XCEL, AtCor, Sydney). Carotid IMT was quantified by vascular ultrasonography. XSP was associated with carotid IMT after adjusting for confounders including age, sex, BMI z-score, heart rate, pubertal stage, moderate-to-vigorous physical activity, and mean arterial pressure (β = 0.93 µm, 95% CI 0.30–1.56 for XSP peak and β = 0.04 µm, 95% CI 0.01–0.08 for XSP integral). The results of the likelihood ratio test indicated a trend that the model with XSP and the above confounders fit better than a similar model without XSP for estimating carotid IMT. Our findings indicate that brachial-cuff device-measured XSP is associated with carotid IMT independent of conventional cardiovascular risk factors, including standard BP. This implies that a clinically convenient cuff approach could provide meaningful information for the early assessment of cardiovascular risk among children. </p

    Fluctuations in the coarsening dynamics of the O(N) model: are they similar to those in glassy systems?

    Full text link
    We study spatio-temporal fluctuations in the non-equilibrium dynamics of the d dimensional O(N) in the large N limit. We analyse the invariance of the dynamic equations for the global correlation and response in the slow ageing regime under transformations of time. We find that these equations are invariant under scale transformations. We extend this study to the action in the dynamic generating functional finding similar results. This model therefore falls into a different category from glassy problems in which full time-reparametrisation invariance, a larger symmetry that emcompasses time scale invariance, is expected to be realised asymptotically. Consequently, the spatio-temporal fluctuations of the large N O(N) model should follow a different pattern from that of glassy systems. We compute the fluctuations of local, as well as spatially separated, two-field composite operators and responses, and we confront our results with the ones found numerically for the 3d Edwards-Anderson model and kinetically constrained lattice gases. We analyse the dependence of the fluctuations of the composite operators on the growing domain length and we compare to what has been found in super-cooled liquids and glasses. Finally, we show that the development of time-reparametrisation invariance in glassy systems is intimately related to a well-defined and finite effective temperature, specified from the modification of the fluctuation-dissipation theorem out of equilibrium. We then conjecture that the global asymptotic time-reparametrisation invariance is broken down to time scale invariance in all coarsening systems.Comment: 57 pages, 5 figure

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P &lt; 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P &lt; 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    Comparison of manual and automated auscultatory blood pressure during graded exercise among people with type 2 diabetes

    No full text
    Manual measurement of blood pressure (BP) during exercise testing is the recommended standard. Automated measurement of BP is an alternative method used during clinical exercise testing, but there is little data comparing manual and automated BP in this setting. The aim of this study was to determine the concordance between manual and automated BP during a standard clinical treadmill exercise test. 416 participants (66 ± 5 years; 54% male) completed a Bruce treadmill exercise test at baseline or follow-up within a clinical trial of participants with type 2 diabetes mellitus. Manual and automated BP were measured simultaneously at each exercise test stage. Manual BP was measured by a technician blinded to automated BP values (Tango+, Suntech). Concordance between manual and automated BP was assessed using mean differences and intraclass correlations (ICC). Concordance between manual and automated BP across all exercise stages was excellent for systolic BP (overall mean difference: 3 ± 11 mm Hg, P = .598; ICC = 0.964 [95% CI 0.942-0.977] and pulse pressure (overall mean difference: 2 ± 14 mm Hg, P = .595; ICC = 0.934 [95% CI 0.899-0.956]). Concordance between manual and automated diastolic BP across all exercise stages was moderate-to-good (overall mean difference: 1 ± 9 mm Hg, P = .905; ICC = 0.784 [95% CI 0.672-0.858]). Automated BP using the Tango + device is concordant with manual BP during early stages of a standard clinical exercise test. Thus, this automated method may be a suitable alternative to manual measurement of BP during clinical exercise testing

    Measuring the Interaction Between the Macro- and Micro-Vasculature

    Get PDF
    International audienceStructural and functional dysfunction in both the macro- and microvasculature are a feature of essential hypertension. In a healthy cardiovascular system, the elastic properties of the large arteries ensure that pulsations in pressure and flow generated by cyclic left ventricular contraction are dampened, so that less pulsatile pressure and flow are delivered at the microvascular level. However, in response to aging, hypertension, and other disease states, arterial stiffening limits the buffering capacity of the elastic arteries, thus exposing the microvasculature to increased pulsatile stress. This is thought to be particularly pertinent to high flow/low resistance organs such as the brain and kidney, which may be sensitive to excess pressure and flow pulsatility, damaging capillary networks, and resulting in target organ damage. In this review, we describe the clinical relevance of the pulsatile interaction between the macro- and microvasculature and summarize current methods for measuring the transmission of pulsatility between the two sites

    Perceptions of pharmacists on the quality of automated blood pressure devices: a national survey

    Get PDF
    A recent study found that only 23.8% of blood pressure (BP) devices available for purchase from Australian pharmacies were validated for accuracy. The extent to which pharmacists are aware of this, and other issues related to the accuracy of BP devices, is not known and gathering this information was the aim of this study. An online survey of Australian pharmacists was distributed via the Pharmaceutical Society of Australia between 1 October and 25 November 2020. Questions were focused on the views of pharmacists related to the accuracy of BP devices. Two hundred and ten pharmacists completed the survey. The accuracy of BP devices sold by pharmacists was considered ‘quite’ or ‘extremely important’ to most respondents (94%). However, most respondents (90%) were unaware that less than one-quarter of BP devices sold by Australian pharmacies were validated, and this was ‘quite’ or ‘extremely surprising’ to many (69%). Many respondents (64%) associated a particular brand of BP device with greater accuracy. There was low awareness on proper ways to identify accurate BP devices, such as checking reputable online databases (43%). BP devices were stocked in respondents’ pharmacies based on perceived quality (50%), accuracy (40%), or as determined by the pharmacy chain (36%). In conclusion, providing accurate BP devices to consumers is important to pharmacists, but they were generally unaware that most devices available from pharmacies were not validated for accuracy. Pharmacist education, alongside advocacy for policies including regulations and strategic action, is required to ensure only validated BP devices are sold in Australia

    Comparison between cuff-based and invasive systolic blood pressure amplification

    No full text
    Objective:Accurate measurement of central blood pressure (BP) using upper arm cuff-based methods is associated with several factors, including determining the level of systolic BP (SBP) amplification. This study aimed to determine the agreement between cuff-based and invasively measured SBP amplification.Methods:Patients undergoing coronary angiography had invasive SBP amplification (brachial SBP - central SBP) measured simultaneously with cuff-based SBP amplification using a commercially available central BP device (device 1: Sphygmocor Xcel; n = 171, 70% men, 60 ± 10 years) and a now superseded model of a central BP device (device 2: Uscom BP+; n = 52, 83% men, 62 ± 10 years).Results:Mean difference (±2SD, limits of agreement) between cuff-based and invasive SBP amplification was 4 mmHg (-12, +20 mmHg, P < 0.001) for device 1 and -2 mmHg (-14, +10 mmHg, P = 0.10) for device 2. Both devices systematically overestimated SBP amplification at lower levels and underestimated at higher levels of invasive SBP amplification, but with stronger bias for device 1 (r = -0.68 vs. r = -0.52; Z = 2.72; P = 0.008). Concordance of cuff-based and invasive SBP amplification across quartiles of invasive SBP amplification was low, particularly in the lowest and highest quartiles. The root mean square errors from regression between cuff-based central SBP and brachial SBP were significantly lower (indicating less variability) than from invasive regression models (P < 0.001).Conclusions:Irrespective of the difference from invasive measurements, cuff-based estimates of SBP amplification showed evidence of proportional systematic bias and had less individual variability. These observations could provide insights on how to improve the performance of cuff-based central BP
    corecore