111 research outputs found
Analysis and Classification of Oximetry Recordings to Predict Obstructive Sleep Apnea Severity in Children
Producción CientíficaCurrent study is focused around the potential use
of oximetry to determine the obstructive sleep apnea-hypopnea
syndrome (OSAHS) severity in children. Single-channel SpO2
recordings from 176 children were divided into three severity
groups according to the apnea-hypopnea index (AHI): AHI<1
events per hour (e/h), 1≤AHI<5 e/h, and AHI ≥5 e/h. Spectral
analysis was conducted to define and characterize a frequency
band of interest in SpO2. Then we combined the spectral data
with the 3% oxygen desaturation index (ODI3) by means of a
multi-layer perceptron (MLP) neural network, in order to
classify children into one of the three OSAHS severity groups.
Following our MLP multiclass approach, a diagnostic protocol
with capability to reduce the need of polysomnography tests by
46% could be derived. Moreover, our proposal can be also
evaluated, in a binary classification task for two common AHI
diagnostic cutoffs (AHI = 1 e/h and AHI= 5 e/h). High
diagnostic ability was reached in both cases (84.7% and 85.8%
accuracy, respectively) outperforming the clinical variable
ODI3 as well as other measures reported in recent studies.
These results suggest that the information contained in SpO2
could be helpful in pediatric OSAHS severity detection.Junta de Castilla y León (project VA059U13
Nocturnal Oximetry-based Evaluation of Habitually Snoring Children
Rationale: The vast majority of children around the world
undergoing adenotonsillectomy for obstructive sleep
apnea–hypopnea syndrome (OSA) are not objectively diagnosed by
nocturnal polysomnography because of access availability and cost
issues. Automated analysis of nocturnal oximetry (nSpO2), which is
readily and globally available, could potentially provide a reliable and
convenient diagnostic approach for pediatric OSA.
Methods: DeidentifiednSpO2 recordings froma total of 4,191 children
originating from13 pediatric sleep laboratories around the worldwere
prospectively evaluated after developing and validating an automated
neural network algorithm using an initial set of single-channel nSpO2
recordings from 589 patients referred for suspected OSA.
Measurements and Main Results: The automatically
estimated apnea–hypopnea index (AHI) showed high
agreement with AHI from conventional polysomnography
(intraclass correlation coefficient, 0.785) when tested in 3,602
additional subjects. Further assessment on the widely used AHI
cutoff points of 1, 5, and 10 events/h revealed an incremental
diagnostic ability (75.2, 81.7, and 90.2% accuracy; 0.788, 0.854, and
0.913 area under the receiver operating characteristic curve,
respectively).
Conclusions: Neural network–based automated analyses of
nSpO2 recordings provide accurate identification of OSA
severity among habitually snoring children with a high pretest
probability of OSA. Thus, nocturnal oximetry may enable a
simple and effective diagnostic alternative to nocturnal
polysomnography, leading to more timely interventions and
potentially improved outcomes.Supported in part by project VA037 U16 from the Consejer´ıa de Educacio´ n de la Junta de Castilla y Leo´ n and the European Regional Development Fund (FEDER), project RTC-2015-3446-1 from the Ministerio de Econom´ıa y Competitividad and FEDER, and project 153/2015 of the Sociedad Espan˜ ola de Neumolog´ıa y Cirug´ıa Tora´ cica (SEPAR). L.K.-G. is supported by NIH grant 1R01HL130984. M.F.P. was supported by a Fellowship Educational grant award from the Kingdom of Saudi Arabia. D.´A. was in receipt of a Juan de la Cierva grant from the Ministerio de Econom´ıa y Competitividad. The funders played no role in the study design, data collection, data analysis, interpretation, and writing of the manuscript
Nocturnal Oximetry-based Evaluation of Habitually Snoring Children
Rationale: The vast majority of children around the world
undergoing adenotonsillectomy for obstructive sleep
apnea–hypopnea syndrome (OSA) are not objectively diagnosed by
nocturnal polysomnography because of access availability and cost
issues. Automated analysis of nocturnal oximetry (nSpO2), which is
readily and globally available, could potentially provide a reliable and
convenient diagnostic approach for pediatric OSA.
Methods: DeidentifiednSpO2 recordings froma total of 4,191 children
originating from13 pediatric sleep laboratories around the worldwere
prospectively evaluated after developing and validating an automated
neural network algorithm using an initial set of single-channel nSpO2
recordings from 589 patients referred for suspected OSA.
Measurements and Main Results: The automatically
estimated apnea–hypopnea index (AHI) showed high
agreement with AHI from conventional polysomnography
(intraclass correlation coefficient, 0.785) when tested in 3,602
additional subjects. Further assessment on the widely used AHI
cutoff points of 1, 5, and 10 events/h revealed an incremental
diagnostic ability (75.2, 81.7, and 90.2% accuracy; 0.788, 0.854, and
0.913 area under the receiver operating characteristic curve,
respectively).
Conclusions: Neural network–based automated analyses of
nSpO2 recordings provide accurate identification of OSA
severity among habitually snoring children with a high pretest
probability of OSA. Thus, nocturnal oximetry may enable a
simple and effective diagnostic alternative to nocturnal
polysomnography, leading to more timely interventions and
potentially improved outcomes.Supported in part by project VA037 U16 from the Consejer´ıa de Educacio´ n de la Junta de Castilla y Leo´ n and the European Regional Development Fund (FEDER), project RTC-2015-3446-1 from the Ministerio de Econom´ıa y Competitividad and FEDER, and project 153/2015 of the Sociedad Espan˜ ola de Neumolog´ıa y Cirug´ıa Tora´ cica (SEPAR). L.K.-G. is supported by NIH grant 1R01HL130984. M.F.P. was supported by a Fellowship Educational grant award from the Kingdom of Saudi Arabia. D.´A. was in receipt of a Juan de la Cierva grant from the Ministerio de Econom´ıa y Competitividad. The funders played no role in the study design, data collection, data analysis, interpretation, and writing of the manuscript
Isabella waltz /
In bound volumes: Copyright Deposits 1820-186
- …