84 research outputs found

    Evaluation of the role of carbon nanotubes on the electrical properties of poly(butylene-terephthalate) nanocomposites for industrial applications

    Get PDF
    In this article, innovative electrically conductive polymer nanocomposites based on poly(butylene terephthalate) (PBT) filled with carbon nanotubes (CNTs) at different concentrations, to be used in the automotive field, have been investigated. Field emission scanning electron microscopy (FESEM) analysis revealed how a good nanofiller dispersion was obtained, especially by using surface treated nanotubes and by processing these materials using a more restrictive screw configuration. Melt flow index measurements highlighted that the processability of these nanocomposites was reduced at elevated filler amounts, even if CNT surface treatment promoted a partial retention of the fluidity of the neat PBT. Thermal degradation stability was improved upon the addition of CNT, even at limited filler amounts. Differential scanning calorimetry measurements evidenced how the presence of CNT slightly increased both the crystallization temperature and the crystalline fraction of the materials. The additivation of CNTs promoted a stiffening effect at elevated CNT contents, associated to an evident embrittlement of the samples. Electrical resistivity measurements showed that the most interesting results (i.e. 2.6 101 Ocm) were obtained for nanocomposites with a total filler content of 3 wt%, processed using the more restrictive screw configuration. For these materials, it was possible to obtain a rapid surface heating through Joule effect at applied voltages of 12 V.The authors gratefully acknowledge Minlargilih Melak Amare for his collaboration in the experimental activities. The authors also acknowledge the Portuguese Foundation for Science and Technology (FCT) for project PEst-C/CTM/LA0025/2013 (LA 25—2015–2017). This research activity has been supported by Fondazione Cassa di Risparmio di Trento e Rovereto (CARITRO) within the project “Bando Caritro 2014 per progetti di ricerca scientifica finalizzati allo sviluppo di iniziative imprenditoriali.” The work was also supported by the National Interuniversitary Consortium of Materials Science and Technology (INSTM)

    Agreement and reliability of two non-invasive methods for assessing cervical range of motion among young adults

    Get PDF
    CONTEXTUALIZAÇÃO: A amplitude de movimento (ADM) cervical é fundamental na avaliação funcional e na intervenção fisioterapêutica. O Cervical Range of Motion (CROM) destaca-se por ser um método confiável, não invasivo e de fácil manuseio, porém de alto custo. Na prática clínica, opta-se por aparelhos mais acessíveis, como o Flexímetro, cuja confiabilidade ainda não foi adequadamente testada para o segmento cervical. OBJETIVOS: Comparar o Flexímetro com o CROM na análise da ADM cervical e verificar a confiabilidade intra e interexaminadores de ambas as ferramentas. MÉTODOS: Os movimentos cervicais de flexão, extensão, inclinação lateral e rotação foram mensurados, com ambas as ferramentas, por três examinadores em 20 indivíduos jovens, do sexo feminino, assintomáticos. A análise estatística foi realizada pelo Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: A concordância entre as ferramentas foi considerada moderada nos movimentos de flexão e rotação esquerda (0,71;0,58) e excelente nos demais movimentos (0,76-0,87). A confiabilidade intraexaminadores com o CROM foi moderada para os movimentos de flexão e rotação direita (0,70; 0,69) e excelente para os demais movimentos (0,79-0,88); com o Flexímetro, foi excelente para inclinação e rotação direita (0,80; 0,77) e moderada para os demais movimentos (0,69-0,75). A confiabilidade interexaminadores com o CROM foi excelente em todos os movimentos (0,76-0,93) e, com o Flexímetro, foi moderada para os movimentos de rotação direita e esquerda (0,66; 0,75) e excelente para os demais movimentos (0,81-0,88). CONCLUSÕES: Os valores obtidos na avaliação da ADM cervical feita pelo Flexímetro concordam com aqueles mensurados pelo CROM. Além disso, ambas as ferramentas apresentam confiabilidades aceitáveis para a prática clínica.BACKGROUND: Cervical range of motion (CROM) is a fundamental component of the functional evaluation in physical therapy interventions. The CROM device stands out as a reliable, non-invasive and easy-to-use method, but it is a very expensive tool. In clinical practice, more affordable tools such as Fleximeters are preferred. However, the reliability of Fleximeters for the cervical spine has not been adequately tested. OBJECTIVES: To compare the Fleximeters and the CROM device for the analysis of CROM, and to investigate the intra- and inter-examiner reliability of both tools. METHODS: Cervical movements (flexion, extension, lateral flexion and rotation) were assessed in 20 asymptomatic young women by three examiners using both tools. The statistical analyses were performed using the intra-class correlation coefficient (ICC). RESULTS: The agreement between the tools was considered moderate for flexion and left rotation (0.71; 0.58) and excellent for all of the other movements (0.76-0.87). The intra-examiner reliability for the CROM device was moderate for flexion and right rotation (0.70; 0.69) and excellent for all of the other movements (0.79-0.88). For the Fleximeter, the agreement was excellent for inclination and right rotation (0.80; 0.77) and moderate for all of the other movements (0.69-0.75). The inter-examiner reliability for the CROM device was excellent for all movements (0.76-0.93) and for the Fleximeter, it was moderate for right and left rotation (0.66; 0.75) and excellent for all of the other movements (0.81-0.88). CONCLUSIONS: There was agreement between the CROM assessments using the Fleximeter and the CROM device. Furthermore, both devices showed acceptable reliability for clinical practice

    Raccomandazioni per l\u2019esecuzione della Curva Standard da Carico Orale di Glucosio (OGTT) per la diagnosi di Diabete Mellito

    Get PDF
    The Oral Glucose Tolerance Test (OGTT) is a fractional method which measures the body's ability to metabolize glucose. Despite its large-scale use, the OGTT is still not appropriately performed in most of the Italian laboratories, as proven by our previous recent survey. In particular, we have provided evidence for the variability for execution of the OGTT in Italian laboratories indicating a poor tendency to standardise the procedures and the methodologies. These findings have been a stimulus to promote an effective Nationwide educational campaign, in order to standardise the procedures for the diagnosis of altered glucose metabolism and diabetes. The present document reports therefore the recommendations concerning the OGTT performed for the classification of diabetes. These recommendations do not apply to the execution of the OGTT during pregnancy for diagnosing gestational diabetes mellitus

    la sicurezza dei prodotti

    No full text
    Il contributo mira ad analizzare, in maniera organica, la disciplina normativa afferente i controlli pubblici in tema di sicurezza dei prodotti, facendo riferimento anche alla disciplina "privatistica" della responsabilità del produttore

    Síntese, Caracterização e Aplicações de Materiais Reciclados a Partir De baterias Íon-Li Exauridas

    Get PDF
    Made available in DSpace on 2018-12-20T13:22:04Z (GMT). No. of bitstreams: 1 tese_12733_Vitor Cezar Broetto Pegoretti.pdf: 5324796 bytes, checksum: a9c155d37621e2456809f6a0f8135b7d (MD5) Previous issue date: 2018-08-31Neste trabalho, foram realizadas duas rotas hidrometalúrgicas para realizar a reciclagem de baterias de íons Li. Na rota A, o cobalto é recuperado de uma bateria de notebook a partir de um cátodo do tipo LiCoO2. O processo de lixiviação foi realizado utilizando ácido sulfúrico e peróxido de hidrogênio, sob agitação e aquecimento. Após a filtração do lixiviado, o hidróxido de cobalto é precipitado utilizando hidróxido de potássio. Hidróxido de cobalto e carbonato de lítio foram misturados e levados a um forno mufla a 800 °C por 5 h. O produto final foi caracterizado por difração de raios-X (DRX) e espectroscopia Raman com imagem constatando-se que se trata do HT-LiCoO2 (grupo espacial R3 ̅m). O material foi submetido a testes de voltametria cíclica que comprovaram a entrada e saída dos íons Li+ da estrutura do HT-LiCoO2. Teste de carga e descarga galvanostática a uma densidade de corrente de 14 mAg-1 foi aplicada na determinação da capacidade específica do HT-LiCoO2. Obteve-se a capacidade específica de 61,5 mAh g-1 no 4° ciclo para um tempo de descarga de 4,4 h. No 15° ciclo, a capacidade especifica foi de 32,5 mAh g-1 para um tempo de descarga de 2 h com eficiência de carga e descarga de 100%. Imagens de microscopia eletrônica de transmissão (MET) revelaram defeitos estruturais nas partículas do material. O HT-LiCoO2 também foi utilizado como eletrocatalisador em reação de desprendimento de oxigênio, em meio alcalino. Medidas de voltametria cíclica e cronoamperometria demonstram que a evolução de oxigênio inicia em 0,35 V após a formação dos íons Co4+. A energia livre de ativação foi calculada usando curvas de Tafel obtendo-se 28 kJ mol-1. Espectroscopia de impedância eletroquímica elucidaram um circuito equivalente com uma resistência à transferência de carga de 1,55 Ω, impedância Warburg de 150,3 Ω e elementos de fase constante de 3,50 e 1,35 mF dentro dos poros e na dupla camada, respectivamente. Na rota B, utilizou-se uma metodologia de reciclagem verde. Um catodo do tipo LiCoxNiyMn1-x-yO2 foi reciclado a partir de uma bateria de notebook, usando uma solução de ácido málico como agente lixiviante. Foram sintetizados três materiais por meio de uma reação do tipo sol-gel na qual variou-se o tempo de síntese e a quantidade de lítio no meio reacional. O CNM10-10h foi obtido após 10 h de tratamento térmico em forno mufla a 900 °C com uma proporção molar inicial Li:(Co+Ni+Mn) de 1,1:1. Por meio de DRX e refinamento Rietveld foi possível identificar que o material é composto por 35,7 % de Co3O4 (F43 ̅m) e 64,3 % de Li0,31Ni0,5Mn0,5O2 (R3 ̅m). Nas imagens de microscopia eletrônica de varredura visualizaram-se partículas octaédricas de, aproximadamente, 1 µm referentes ao Co3O4.Nas imagens de MET foi possível observar a formação de nanobastões pertencentes à fase litiada. O material apresentou bons resultados como pseudocapacitor uma capacitância específica de 4,6 F g−1 no 1000º ciclo de uma voltametria a 10 mV s−1, e como sensor não enzimático na quantificação de ácido ascórbico com uma sensibilidade de 360,34 µA L mol-1 cm-2 e uma região linear de trabalho no intervalo de 0,55 mmol L−1. Os materiais CNM10-3h e CNM20-3h foram obtidos após tratamento térmico de 3 h em forno mufla e variou-se a proporção Li:(Co+Ni+Mn) sendo 1,1:1 no composto (CNM10-3h) e 1,2:1 no (CNM20-3h) . Análises de DRX com refinamento Rietveld indicaram que a amostra CNM10-3h é composta por 21,8% de Co3O4 (F43 ̅m) e 78,2% de LiCo0,28Ni0,33Mn0,34O2 (R3 ̅m). A amostra CNM20-3h é composta por 14,7 % de Co3O4 (F43 ̅m) e 85,3 % de Li0.94Co0.25Ni0.34Mn0.41O2 (R3 ̅m). Ambos os materiais foram submetidos a testes de voltametria cíclica identificando-se a entrada e saída dos íons Li+ na estrutura do LiCo0,28Ni0,33Mn0,34O2. Teste de carga e descarga galvanostática a uma densidade de corrente de 14 mA.g-1 foram realizados nas amostras CNM10-3h e CNM20-3h e uma capacidade específica no 1º ciclo de 80 mAh g-1 e 119 mAh g-1, respectivamente, foi obtida. Testes prolongados de carga e descarga foram realizados na amostra CNM20-3h para 15 ciclos obtendo uma capacidade de 39,7 mAh g-1 no último ciclo com uma eficiência de carga e descarga de 88,8%. Portanto, as rotas de reciclagem propostas neste trabalho se mostram eficientes para a produção de materiais com diferentes aplicações tecnológicas
    corecore