116 research outputs found

    Effect of an Herbal/Botanical Supplement on Strength, Balance, and Muscle Function Following 12-Weeks of Resistance Training: A Placebo Controlled Study

    Get PDF
    Background: StemSport (SS; StemTech International, Inc. San Clemente, CA) contains a proprietary blend of the botanical Aphanizomenon flos-aquae and several herbal antioxidant and anti-inflammatory substances. SS has been purported to accelerate tissue repair and restore muscle function following resistance exercise. Here, we examine the effects of SS supplementation on strength adaptations resulting from a 12-week resistance training program in healthy young adults. Methods: Twenty-four young adults (16 males, 8 females, mean age = 20.5 ± 1.9 years, mass = 70.9 ± 11.9 kg, stature = 176.6 ± 9.9 cm) completed the twelve week training program. The study design was a double-blind, placebo controlled parallel group trial. Subjects either received placebo or StemSport supplement (SS; mg/day) during the training. 1-RM bench press, 1-RM leg press, vertical jump height, balance (star excursion and center of mass excursion), isokinetic strength (elbow and knee flexion/extension) and perception of recovery were measured at baseline and following the 12-week training intervention. Results: Resistance training increased 1-RM strength (p \u3c 0.008), vertical jump height (p \u3c 0.03), and isokinetic strength (p \u3c 0.05) in both SS and placebo groups. No significant group-by-time interactions were observed (all p-values \u3e0.10). Conclusions: These data suggest that compared to placebo, the SS herbal/botanical supplement did not enhance training induced adaptations to strength, balance, and muscle function above strength training alone

    Effect of an Herbal/Botanical Supplement on Recovery from Delayed Onset Muscle Soreness: A Randomized Placebo Controlled Trial

    Get PDF
    Background: We examined the effects of a proprietary herbal/botanical supplement (StemSport, Stemtech, San Clemente, CA.) suggested to increase circulating stem cells, decrease inflammation, and attenuate exercise induced muscle damage on recovery from delayed onset muscle soreness (DOMS). Methods: Sixteen subjects (male = 7, female = 9; age 23.8 ± 10 years; height 171.9 ± 10 cm, mass 72.2 ± 15 kg) were randomized in a crossover, double-blind, placebo controlled trial to receive a placebo or StemSport supplement (6150 mg/day) for 14 days. DOMS was induced on day 7 for both placebo and active conditions in the non-dominant elbow flexor group with repeated eccentric repetitions. Muscle swelling (biceps girth), elbow flexor isometric strength (hand held dynamometer), muscle pain/tenderness (visual analog scale), range of motion (active elbow flexion and extension), and inflammation (hsCRP, IL6, and TNF-ɑ) were measured at baseline and at 24 h, 48 h, 72 h, and 168 h (1 week) post eccentric exercise. The crossover washout period was \u3e= 14 days. Results: No significant condition-by-time interactions between placebo and StemSport supplementation were observed with regard to measures of pain (p = 0.59), tenderness (p = 0.71), isometric strength (p = 0.32), elbow flexion (p = 0.45), muscle swelling (p = 0.90), or inflammation (p \u3e 0.90). Decrements in elbow extension range of motion 48 h post-exercise were less after StemSport supplementation (Δ elbow extension 48 h post; StemSport, -2.0 deg; placebo, -10 deg; p = 0.003). Conclusions: These data suggest that compared to placebo, StemSport supplementation does not improve outcome measures related to muscle recovery after acute upper-arm induced DOMS

    Glove-Enabled Computer Operations (GECO): Design and Testing of an Extravehicular Activity Glove Adapted for Human-Computer Interface

    Get PDF
    The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants' mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99% in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text "chat" communications, manipulation of procedures/checklists, cataloguing/annotating images, scientific note taking, human-robot interaction, and control of suit and/or other EVA systems

    Fluoroscopy-guided jejunal extension tube placement through existing gastrostomy tubes: analysis of 391 procedures

    Get PDF
    PURPOSEWe aimed to evaluate the safety and efficacy of fluoroscopically placed jejunal extension tubes (J-arm) in patients with existing gastrostomy tubes.METHODSWe conducted a retrospective review of 391 J-arm placements performed in 174 patients. Indications for jejunal nutrition were aspiration risk (35%), pancreatitis (17%), gastroparesis (13%), gastric outlet obstruction (12%), and other (23%). Technical success, complications, malfunctions, and patency were assessed. Percutaneous gastrostomy (PEG) tube location, J-arm course, and fluoroscopy time were correlated with success/failure. Failure was defined as inability to exit the stomach. Procedure-related complications were defined as adverse events related to tube placement occurring within seven days. Tube malfunctions and aspiration events were recorded and assessed.RESULTSTechnical success was achieved in 91.9% (95% CI, 86.7%–95.2%) of new tubes versus 94.2% (95% CI, 86.7%–95.2%) of replacements (P = 0.373). Periprocedural complications occurred in three patients (0.8%). Malfunctions occurred in 197 patients (50%). Median tube patency was 103 days (95% CI, 71–134 days). No association was found between successful J-arm placement and gastric PEG tube position (P = 0.677), indication for jejunal nutrition (P = 0.349), J-arm trajectory in the stomach and incidence of malfunction (P = 0.365), risk of tube migration and PEG tube position (P = 0.173), or J-arm length (P = 0.987). A fluoroscopy time of 21.3 min was identified as a threshold for failure. Malfunctions occurred more often in tubes replaced after 90 days than in tubes replaced before 90 days (P < 0.001). A total of 42 aspiration events occurred (OR 6.4, P < 0.001, compared with nonmalfunctioning tubes).CONCLUSIONFluoroscopy-guided J-arm placement is safe for patients requiring jejunal nutrition. Tubes indwelling for longer than 90 days have higher rates of malfunction and aspiration

    Effect of an herbal/botanical supplement on strength, balance, and muscle function following 12-weeks of resistance training: a placebo controlled study

    Get PDF
    Background: StemSport (SS; StemTech International, Inc. San Clemente, CA) contains a proprietary blend of the botanical Aphanizomenon flos-aquae and several herbal antioxidant and anti-inflammatory substances. SS has been purported to accelerate tissue repair and restore muscle function following resistance exercise. Here, we examine the effects of SS supplementation on strength adaptations resulting from a 12-week resistance training program in healthy young adults. Methods: Twenty-four young adults (16 males, 8 females, mean age = 20.5 ± 1.9 years, mass = 70.9 ± 11.9 kg, stature = 176.6 ± 9.9 cm) completed the twelve week training program. The study design was a double-blind, placebo controlled parallel group trial. Subjects either received placebo or StemSport supplement (SS; mg/day) during the training. 1-RM bench press, 1-RM leg press, vertical jump height, balance (star excursion and center of mass excursion), isokinetic strength (elbow and knee flexion/extension) and perception of recovery were measured at baseline and following the 12-week training intervention. Results: Resistance training increased 1-RM strength (p \u3c 0.008), vertical jump height (p \u3c 0.03), and isokinetic strength (p \u3c 0.05) in both SS and placebo groups. No significant group-by-time interactions were observed (all p-values \u3e0.10). Conclusions: These data suggest that compared to placebo, the SS herbal/botanical supplement did not enhance training induced adaptations to strength, balance, and muscle function above strength training alone

    Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    Get PDF
    Introduction: Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. Methods: We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40%/60% with appropriate noise indices. The weighted volume CT dose index (CTDIvol), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. Results: For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDIvol and DLP were lowered by up to 10.9% (p < 0.001), 17.9% (p = 0.005), 20.9% (p < 0.001), and 21.7% (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. Conclusion: We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality

    Manual therapy directed at the knee or lumbopelvic region does not influence quadriceps spinal reflex excitability

    Get PDF
    Manual therapies, directed to the knee and lumbopelvic region, have demonstrated the ability to improve neuromuscular quadriceps function in individuals with knee pathology. It remains unknown if manual therapies may alter impaired spinal reflex excitability, thus identifying a potential mechanism in which manual therapy may improve neuromuscular function following knee injury

    How many human proteoforms are there?

    Get PDF
    Despite decades of accumulated knowledge about proteins and their post-translational modifications (PTMs), numerous questions remain regarding their molecular composition and biological function. One of the most fundamental queries is the extent to which the combinations of DNA-, RNA- and PTM-level variations explode the complexity of the human proteome. Here, we outline what we know from current databases and measurement strategies including mass spectrometry-based proteomics. In doing so, we examine prevailing notions about the number of modifications displayed on human proteins and how they combine to generate the protein diversity underlying health and disease. We frame central issues regarding determination of protein-level variation and PTMs, including some paradoxes present in the field today. We use this framework to assess existing data and to ask the question, "How many distinct primary structures of proteins (proteoforms) are created from the 20,300 human genes?" We also explore prospects for improving measurements to better regularize protein-level biology and efficiently associate PTMs to function and phenotype
    • …
    corecore