57 research outputs found

    A Novel Implantable Glaucoma Valve Using Ferrofluid

    Get PDF
    Purpose To present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve. Setting: Massachusetts Eye & Ear Infirmary, Boston, USA. Methods: A glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid) as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmedā„¢ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD) analysis over a period of eight weeks. In vivo assessment was performed in three rabbits. Results: In the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 Āµl/min at 12 mmHg; 4.3 Āµl/min at 16 mmHg; 7.6 Āµl/min at 21 mmHg). X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits. Conclusions: The proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway

    Low-Cost and Readily Available Tissue Carriers for the Boston Keratoprosthesis: A Review of Possibilities

    Get PDF
    The Boston keratoprosthesis (B-KPro), currently the most commonly used artificial cornea worldwide, can provide rapid visual rehabilitation for eyes with severe corneal opacities not suitable for standard corneal transplantation. However, the B-KPro presently needs a corneal graft as a tissue carrier. Although corneal allograft tissue is readily available in the United States and other developed countries with established eye banks, the worldwide need vastly exceeds supply. Therefore, a simple, safe, and inexpensive alternative to corneal allografts is desirable for the developing world. We are currently exploring reasonable alternative options such as corneal autografts, xenografts, noncorneal autologous tissues, and laboratory-made tissue constructs, as well as modifications to corneal allografts, such as deep-freezing, glycerol-dehydration, gamma irradiation, and cross-linking. These alternative tissue carriers for the B-KPro are discussed with special regard to safety, practicality, and cost for the developing world

    Reliable intraocular pressure measurement using automated radio-wave telemetry

    Get PDF
    Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08Ā±2.2 mmHg) and mean vehicle IOP (13.27Ā±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3Ā±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62Ā±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was Ā±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (ā‰¤1 minute), during which the IOP is not expected to change. Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results
    • ā€¦
    corecore